Vent-Axia Lo-Carbon Quadra HTP Installation And Wiring Instructions Download Page 4

A. INSTALLATION 

 
A Backdraught Shutter Assembly is supplied. It is packed inside the product during transport. It is 
designed to block the duct when the fan is off in order to prevent cold draughts from outside 
entering the building. If you are going to set the fan up to extract air continuously (constant trickle), 
you do not necessarily need it. To use it, push it on to the end of the exhaust Spigot with the 
hinges on the flaps vertical (

fig.1

).  

 
IMPORTANT: Be careful to avoid joists and hidden pipes or cables when cutting or drilling holes.  
 
 

SURFACE MOUNTING

 

(PANEL/CEILING)

 

1. 

Remove the Front Cover Assembly by slackening the 2 Cover Screws by 2 turns (

fig.2.) 

 Lift 

the Cover Assembly away from the bottom edge then the top edge

.

  

2. 

Cut a 

105mm hole and suitable screw holes in the panel, ensuring that there is sufficient 

space for the product to be installed and that the optional Filter (

fig.3

) could be removed for 

cleaning. The cardboard fitment in the packaging can be used as a template.  

3. 

Set-up the appropriate speed selection and other features as outlined in 

Section B SETUP. 

 

4. 

Remove the small Internal Cover that covers the Terminal Block in the top right corner (

fig.3

). 

5. 

Attach the ducting to the Spigot and locate the Fan into the hole in the panel. Feed wiring 
through the hole in the Chassis next to the Terminal Block as you do so. 

(fig. 4)

 

6. 

Secure into position using appropriate screws and rawl plugs. 

7. 

Select and follow the appropriate wiring diagram in 

Section C WIRING.

 

8. 

Replace the Internal Cover over the Terminal Block. 

9. 

Ensure the Impeller rotates freely. 

10.  Replace the Front Cover Assembly and tighten the two screws. 
11.  Switch the mains power supply on and check the fan is operating correctly. 
 

SURFACE MOUNTING

 

(WALL)

 

For through-the-wall installations, a Wall Kit (25 41 02 White / 25 41 00 Brown) can be used. 
1. 

Remove the Front Cover Assembly by slackening the 2 Cover Screws by 2 turns (

fig.2.) 

 Lift 

the front assembly away from the bottom edge then the top edge. 

2. 

Cut a 

117mm hole through the wall, ensuring that there is sufficient space for the product to 

be installed and that the optional Filter (

fig.3

) can be removed for maintenance. The 

cardboard fitment inside the packaging can be used as a template.  

3. 

Insert the wall sleeve with the larger diameter sleeve on the room-side and cement the ends 
into position flush with the wall faces. The wall sleeve should be angled downwards, away 
from the Fan, to allow any condensation to drain to outside. 

4. 

Outside Grille (available separately): Using the 

Grille’s Back Plate as a template, mark the 

fixing hole centres on the wall. Drill and plug the wall and fix the Grille into position. Ensure 
the louvres are pointing downwards. 

5. 

Set-up the appropriate speed selection and other features as outlined in 

Section B SETUP.

 

6. 

Remove the small Internal Cover that covers the Terminal Block in the top right corner (

fig 3

). 

7. 

Using the Fan Chassis as a template, carefully sliding the spigot into the Wall Liner, mark the 
fixing hole centres on the wall.  

8. 

Drill and plug the wall using the fixings provided. 

9. 

Feed the wiring through the hole near the Terminal Block (

fig.

4) and secure the Fan into 

position using the screws provided.  

10.  Select and follow the appropriate wiring diagram in 

Section C WIRING.

 

11.  Replace the Internal Cover over the Terminal Block.  
12.  Ensure the Impeller (

fig.3

) rotates freely. 

13.  Replace the Front Cover Assembly and tighten the two screws. 
14.  Switch the mains power supply on and check the fan is operating correctly 

 

 

Summary of Contents for Lo-Carbon Quadra HTP

Page 1: ...Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Lo Carbon Quadra Centrifugal Fan 220 240V 50Hz Stock Ref N Quadra TP 439251A Quadra TM 439253A Q...

Page 2: ...n accessory 439927 Option to boost from constant trickle or from off Three trickle speed options available selectable during installation 6 9 or 12 l s Three boost speed options available selectable d...

Page 3: ...adequate for both the fan and the fuel burning appliance G The Fan should not be used where it is liable to be subject to direct water spray for prolonged periods of time H Where ducted Fans are used...

Page 4: ...mains power supply on and check the fan is operating correctly SURFACE MOUNTING WALL For through the wall installations a Wall Kit 25 41 02 White 25 41 00 Brown can be used 1 Remove the Front Cover A...

Page 5: ...the hole in the panel ensuring the cable is fed into the Fan Chassis fig 4 and the Panel Clips spring out behind the panel 8 Secure into position by carefully tightening the 4 Panel Clip Screws IMPOR...

Page 6: ...t rate use the integral pullcord or remote switch via the LS connection i To LOWER the Set Point turn the Humidity Adjuster figs 4 7 ANTI CLOCKWISE This makes the fan more sensitive to RH i e the fan...

Page 7: ...wet cloth until clean 6 Wash the Filter Cover Assembly and Impeller in warm soapy water if they are dirty Do not use abrasive cleaners Dry the parts before replacing them 7 Turn the power to the Fan...

Page 8: ...Terminal Block Cover Spigot Cover Assembly Chassis Assembly Impeller Optional Filter Fig 4 Internal Terminal Block Cover Cable Clamp Terminal Block Timer and Humidity Adjustment Speed and Installation...

Page 9: ...Fig 5 Frame from optional Flush Mount Kit Back Box Fig 6 Panel Clip Screw 4 off Panel Clip 4 off...

Page 10: ...Speed Selection Switches Factory setting shown is boost speed of 15 l s and normal trickle speed of 6 l s Installation Type Selection Switches Through the wall installation 1 5m 100mm ducting with one...

Page 11: ...Fig 10 Wiring diagram with LS connection N L Ls 1 Phase Supply 220 240V 50 Hz 3A Fuse Pull Cord Lamp 3 Pole Isolator Switch Ceiling Junction Pull Cord if applicable Fan N L L N 1 Phase Supply 220 240...

Page 12: ...tor CTRL 0 65 0 65 0 65 Control Typology Clock Control Local Demand Control Local Demand Control Declared Max Internal External Leakage Rates for BVUs or carry over for regenerative heat exchangers on...

Page 13: ......

Page 14: ...vent of any part being found to be defective the product will be repaired or at the Company s option replaced without charge provided that the product Has been installed and used in accordance with th...

Reviews: