Technical Specifications 

(Tested at 240 VAC @ 50Hz)

 

Air Performance: 6, 9, 12, 15, 30 or 60 l/s (22, 32, 43, 54, 108 or 216 m³/h). 

 

Power consumption: 3 - 45W. 

 

Exhaust spigot diameter: Ø100mm. 

 

Installed size: 260 x 230 x 112 mm (when surface mounted) 

 
 
Features: 

 

Surface mountable. 

 

Can be flush mounted with optional accessory kit (439256). 

 

Optional Filter available as an accessory (439927). 

 

Option to boost from constant trickle or from off. 

 

Three trickle speed options available, selectable during installation (6, 9 or 12 l/s). 

 

Three boost speed options available, selectable during installation (15, 30 or 60 l/s). 

 

LS connection (remote switch can switch the fan from the off or trickle state to boost).  

 

Adjustable timer overrun (1-30 minutes approximately). 

 

Variable speed boost for humidity models.  

 
 
Model Specific Methods to Select Boost Speed: 

TP 

TM 

HTP 

 

Pullcord 

 

 

 

 

Movement sensor (P.I.R) 

 

 

 

 

Adjustable relative humidity sensor 

 

 

 

 

Summary of Contents for Lo-Carbon Quadra HTP

Page 1: ...Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Lo Carbon Quadra Centrifugal Fan 220 240V 50Hz Stock Ref N Quadra TP 439251A Quadra TM 439253A Q...

Page 2: ...n accessory 439927 Option to boost from constant trickle or from off Three trickle speed options available selectable during installation 6 9 or 12 l s Three boost speed options available selectable d...

Page 3: ...adequate for both the fan and the fuel burning appliance G The Fan should not be used where it is liable to be subject to direct water spray for prolonged periods of time H Where ducted Fans are used...

Page 4: ...mains power supply on and check the fan is operating correctly SURFACE MOUNTING WALL For through the wall installations a Wall Kit 25 41 02 White 25 41 00 Brown can be used 1 Remove the Front Cover A...

Page 5: ...the hole in the panel ensuring the cable is fed into the Fan Chassis fig 4 and the Panel Clips spring out behind the panel 8 Secure into position by carefully tightening the 4 Panel Clip Screws IMPOR...

Page 6: ...t rate use the integral pullcord or remote switch via the LS connection i To LOWER the Set Point turn the Humidity Adjuster figs 4 7 ANTI CLOCKWISE This makes the fan more sensitive to RH i e the fan...

Page 7: ...wet cloth until clean 6 Wash the Filter Cover Assembly and Impeller in warm soapy water if they are dirty Do not use abrasive cleaners Dry the parts before replacing them 7 Turn the power to the Fan...

Page 8: ...Terminal Block Cover Spigot Cover Assembly Chassis Assembly Impeller Optional Filter Fig 4 Internal Terminal Block Cover Cable Clamp Terminal Block Timer and Humidity Adjustment Speed and Installation...

Page 9: ...Fig 5 Frame from optional Flush Mount Kit Back Box Fig 6 Panel Clip Screw 4 off Panel Clip 4 off...

Page 10: ...Speed Selection Switches Factory setting shown is boost speed of 15 l s and normal trickle speed of 6 l s Installation Type Selection Switches Through the wall installation 1 5m 100mm ducting with one...

Page 11: ...Fig 10 Wiring diagram with LS connection N L Ls 1 Phase Supply 220 240V 50 Hz 3A Fuse Pull Cord Lamp 3 Pole Isolator Switch Ceiling Junction Pull Cord if applicable Fan N L L N 1 Phase Supply 220 240...

Page 12: ...tor CTRL 0 65 0 65 0 65 Control Typology Clock Control Local Demand Control Local Demand Control Declared Max Internal External Leakage Rates for BVUs or carry over for regenerative heat exchangers on...

Page 13: ......

Page 14: ...vent of any part being found to be defective the product will be repaired or at the Company s option replaced without charge provided that the product Has been installed and used in accordance with th...