Vent-Axia EKF355E1 Installation And Wiring Instructions Download Page 8

 

 

 
 
 

8

ACCESSORIES

 

 

Part No. 

Description 

EKFFC355 

EKF355 FLEXIBLE CONNECTOR KIT 

EKFFC400 

EKF400 FLEXIBLE CONNECTOR KIT 

EKFFC500 

EKF500 FLEXIBLE CONNECTOR KIT 

  

  

EKFTP35-35 

EKF355 TRANSFORMATION PIECE TO 350 CIRCULAR DUCT 

EKFTP40-40 

EKF400/450 TRANSFORMATION PIECE TO 400 CIRCULAR DUCT 

EKFTP40-45 

EKF400/450 TRANSFORMATION PIECE TO 450 CIRCULAR DUCT 

EKFTP50-50 

EKF500/560 TRANSFORMATION PIECE TO 500 CIRCULAR DUCT 

EKFTP50-56 

EKF500/560 TRANSFORMATION PIECE TO 560 CIRCULAR DUCT 

  

  

EKFMF355 

EKF355 MOUNTING FEET KIT 

EKFMF400 

EKF400 MOUNTING FEET KIT 

EKFMF500 

EKF500 MOUNTING FEET KIT 

  

  

EKFWR355 

EKF355 WEATHER ROOF 

EKFWR400 

EKF400 WEATHER ROOF 

EKFWR500 

EKF500 WEATHER ROOF 

  

  

EKFDC355 

EKF355 DISCHARGE COWL 

EKFDC400 

EKF400 DISCHARGE COWL 

EKFDC500 EKF500 

DISCHARGE 

COWL 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 

Head Office: Fleming Way, Crawley, West Sussex, RH10 9YX.  
 

UK NATIONAL CALL CENTRE

, Newton Road, Crawley, West Sussex, RH10 9JA

 

SALES ENQUIRIES: 

  

Tel: 0844 8560590  

Fax: 01293 565169

  

TECHNICAL SUPPORT: 

Tel: 0844 8560594  

Fax: 01293 539209 

For details of the warranty and returns procedure please refer to www.vent-axia.com or write to Vent-Axia Ltd, Fleming Way, Crawley, RH10 9YX

 

 
405570 

           1015 

 
 

The

 



 

Guarantee 

 

Applicable only to products installed and used in the United Kingdom.  For details of guarantee outside 

the United Kingdom contact your local supplier. 

 

Vent-Axia guarantees its products for two years from date of purchase against faulty material or 

workmanship.  In the event of any part being found to be defective, the product will be repaired, or at 

the Company’s option replaced, without charge, provided that the product:- 

 

  Has been installed and used in accordance with the instructions given with each unit. 

  Has not been connected to an unsuitable electricity supply. (The correct electricity supply 

voltage is shown on the product rating label attached to the unit). 

  Has not been subjected to misuse, neglect or damage. 

  Has not been modified or repaired by any person not authorised by the company. 

 

IF CLAIMING UNDER TERMS OF GUARANTEE 

Please return the complete product, carriage paid to your original supplier or nearest Vent-Axia Centre, 

by post or personal visit.  Please ensure that it is adequately packed and accompanied by a letter 

clearly marked “Guarantee Claim” stating the nature of the fault and providing evidence of date and 

source of purchase. 

 

The guarantee is offered to you as an extra benefit, and does not affect your legal rights 

Summary of Contents for EKF355E1

Page 1: ...EKF EC kitchen extract fan range Stock Ref N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3 Installation and Wiring Instructions...

Page 2: ...S OF HEAT AMBIENT TEMPERATURE RANGE IS 20 C TO 40 C OUTSIDE OF FAN AND DUCTWORK MAX 120 C IN DUCT 6 WHEN INSTALLING UNIT TAKE CARE NOT TO DAMAGE ELECTRICAL OR OTHER HIDDEN UTILITIES 7 CHECK THE DETAIL...

Page 3: ...lengths of ducting Short duct runs terminating close to the fan i e within 1 5m must incorporate suitable guards unless the fan is mounted higher than 2 1m above the floor Position the fan at the hig...

Page 4: ...Mounting the unit If mounting the unit outdoors the unit MUST be installed with a weather roof fitted see accessories list it is suggested that the unit is mounted at least 150mm off the floor surface...

Page 5: ...tened 4 The cable entry must be made using the knockouts provided 5 Replace isolator cover terminal box cover 6 Ensure the impeller rotates and is free from obstructions Notes 1 24V D1 should always b...

Page 6: ...KF450E1 Controls box Isolator Variable speed 230V 1Ph 50Hz Applies to EKF450E3 EKF500E3 EKF560E3 Controls box Isolator Full speed 400V 3Ph 50Hz Applies to EKF450E3 EKF500E3 EKF560E3 Controls box Isola...

Page 7: ...for more information should this occur Servicing Maintenance WARNING THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING MAINTENANCE 1 At intervals appropriate to th...

Page 8: ...ing Way Crawley RH10 9YX 405570 B 1015 The Guarantee Applicable only to products installed and used in the United Kingdom For details of guarantee outside the United Kingdom contact your local supplie...

Reviews: