L124 0516A

VENTING

ACCESSORIES

6” RECTANGULAR DUCT PIPE

MODEL

DIM

VP507

6” x 8 ½”

24”

8 ½”

6”

ROUND DUCT PIPE

MODEL

DIM

VP500

VP501

VP502

6” Round

7” Round

8” Round

36”

6”

7”

8”

3 ¼” RECTANGULAR DUCT PIPE

MODEL

DIM

VP504

VP505

VP506

3 ¼” x 10”

3 ¼” x 12”

3 ¼” x 16”

30”

10”

12”

16”

3 ¼”

OFFSET L & R TRANSITION

FOR ISLAND BLOWERS

MODEL

DIM

VP542

VP543

Top Left

Top Right

8”

12”

5”

16”

SIDE VENT TRANSITION L & R

FOR ISLAND BLOWERS

MODEL

DIM

VP544

VP545

Left Side

Right Side

19”

8”

16”

5”

OFFSET KIT - RECTANGULAR

MODEL

DIM

VP550

6” Rnd to 3 ¼” x 10”

16”

11”

6”

11”

3 ¼”

10”

STANDARD ISLAND TRANSITION

MODEL

DIM

VP565

5” x 16” to 8”

8”

9”

16”

5”

CLUSTER BLOWER TRANSITION

MODEL

DIM

VP564

8” & 8” to 12”

18 ½”

12”

11 ¼”

“Y” TRANSITION

MODEL

DIM

VP517

VP518

VP551

8” & 8” to 12”

6” & 8” to 12”

6” & 8” to 10”

18”

10”

12”

3 ¼” x 10” BACK VENT ELBOW

MODEL

DIM

VP559

3 ¼” x 10”

4 ¼”

10”

14”

3 ¼”

3 ¼”

MULTI-BLOWER TRANSITION

MODEL

DIM

VP562

VP563

6” & 8” to 10”

8” & 8” to 12”

VP562 - 17 ½”

VP563 - 16 ½”

10”

12”

VP562 - 23 ¼”

VP563 - 30 ½”

3 ¼” x 10” TO 7” TRANSITION

MODEL

DIM

VP521

3 ¼” x 10” to 7”

7”

7 ½”

3 ¼”

10”

LOW PROFILE ROOF JACK

(MAXIMUM 4/12 PITCH)

MODEL

DIM

6 ½”

VP539

VP540

VP541

6” Round

7” Round

8” Round

16 ¾”

16 ¾”

LOW PROFILE ROOF JACK

(MAXIMUM 4/12 PITCH)

MODEL

DIM

10 ½”

VP552

VP553

10” Round

12” Round

22 ½”

20 ¾”

ADJUSTABLE ELBOW

MODEL

DIM

VP513

VP514

VP515

6” Round

7” Round

8” Round

6”

7”

8”

VP513 - 8 ½”

VP514 - 9 9⁄16”

VP515 - 10 5⁄8”

BACK/SIDE VENT ELBOW

MODEL

DIM

VP561

8” to 6” x 8 ½”

12”

6”

16”

8” Round

8 ½”

WALL LOUVER

MODEL

DIM

6”

7”

8”

8 5⁄8”

VP526

VP527

VP528

6” Round

7” Round

8” Round

Back

View

1 ½” Flange

WALL LOUVER

MODEL

DIM

11”

11”

VP554

10” Round

Back

View

1 ½” Flange

WALL LOUVER

MODEL

DIM

13”

13”

VP555

12” Round

Back

View

1 ½” Flange

RECTANGULAR WALL LOUVER

MODEL

DIM

3 ¼”

10”

VP538

VP560

6” x 8 ½“

3 ¼” x 10”

8 ½”

6”

1 ½”

 FLANGE

2” FLANGE

OFFSET KIT - ROUND

MODEL

DIM

VP529

6” Rnd to 7” Rnd

16”

11”

6”

7”

10 ½”

LOW PROFILE ROOF JACK

(MINIMUM 4/12 PITCH)

MODEL

DIM

10 ½”

VP552-HP

VP553-HP

10” Round

12” Round

22 ½”

20 ¾”

M1200 STANDARD TRANSITION

MODEL

DIM

VP566

21” x 8” to 10”

10”

9”

8”

21”

LOW PROFILE ROOF JACK

(MINIMUM 4/12 PITCH)

MODEL

DIM

6 ½”

VP539-HP

VP540-HP

VP541-HP

6” Round

7” Round

8” Round

16 ¾”

16 ¾”

Summary of Contents for AH12

Page 1: ...o wall or ceiling do not damage electrical wiring and other hidden utilities C Ducted fans must always be vented to the outdoors D Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Pr...

Page 2: ...rements and placement of duct against combustibles Make the duct run as short and as straight as possible with as few turns as possible Avoid sharp angled turns Instead use smooth gradual turns such as adjustable elbows or 45 degree angled turns For duct runs over 20 feet increase the duct diameter by one inch for every ten feet of duct A 90 degree elbow is equal to 5 feet of duct Using Vent A Hoo...

Page 3: ...Consult the connection diagram on next page for further details on exhaust outlet placement Use duct tape to seal all joints A complete listing of available Vent A Hood ducting materials is provided on the back page of this instruction sheet 4 Place the ceiling collar on the ceiling with the notched side 1 16 from the wall Center the ceiling collar over the location where the hood will hang Trace ...

Page 4: ...an shield s inside the hood Remove the E Z Clean shield s by lightly pulling it toward the front of the hood Gently close the back draft damper s from the top side of the hood To remove the blower housing s unsnap the suitcase latches one on each side of the housing The housing s should be pulled forward and gently tipped to clear the blower wheel s and then out of the hood 7 Remove the three scre...

Page 5: ...to ensure that the electrical wire does not get pinched Secure the hood to the wood mounting strip by installing the screws previously removed from the strip in Step 10 into the pilot holes drilled in Step 11 14 From inside the hood using UL listed wire nuts attach the neutral wire to the white lead inside the motor box the hot wire to the black lead inside the motor box and the ground wire to the...

Page 6: ... 23 VP563 30 3 x 10 TO 7 TRANSITION MODEL DIM VP521 3 x 10 to 7 7 7 3 10 LOW PROFILE ROOF JACK MAXIMUM 4 12 PITCH MODEL DIM 6 VP539 VP540 VP541 6 Round 7 Round 8 Round 16 16 LOW PROFILE ROOF JACK MAXIMUM 4 12 PITCH MODEL DIM 10 VP552 VP553 10 Round 12 Round 22 20 ADJUSTABLE ELBOW MODEL DIM VP513 VP514 VP515 6 Round 7 Round 8 Round 6 7 8 VP513 8 VP514 9 9 16 VP515 10 5 8 BACK SIDE VENT ELBOW MODEL ...

Reviews: