Venmar VCQLA1 Series Installation Use And Care Manual Download Page 23

INST
ALLA
TION MANUAL

SERVICE P

AR

TS

23

VCQLA1 SERIES

K

EY

 

NO

.

P

ART

 

NO

.

D

ESCRIPTION

Q

UANTITY

W

HITE

S

TAINLESS

30" 

36"

30

"

36"

1

S97020030

R

ECIRCULATION

 

COVER

 

PLATE

, W

HITE

 (

INCLUDING

 

SCREWS

)

1

1

S97020031

R

ECIRCULATION

 

COVER

 

PLATE

, S

TAINLESS

 

STEEL

 (

INCLUDING

 

SCREWS

)

1

1

2

SR680508

7'' R

OUND

 

DUCT

 

PLATE

 (

INCLUDING

 

SCREWS

)

1

1

1

1

3

S97020534

3¼” 

X

 10” D

AMPER

 

ASS

Y

 (

INCLUDING

 

SCREWS

)

1

1

1

1

4

S97020412

C

APACITOR

 (

INCLUDING

 

TIE

 

WRAP

)

2

2

2

2

5

S97020797

A

UTOTRANSFORMER

 (

WITH

 

SCREWS

)

1

1

1

1

6

S97020842

B

LOWER

 A

SS

'

Y

 CW (

INCLUDING

 

ITEMS

 4 

AND

 7 

AND

 

HARDWARE

)

1

1

1

1

7

SR99420635

C

LIP

 

FOR

 

FANPELLER

2

2

2

2

8

S97020204-002

G

REASE

 F

ILTER

 - H

YBRID

 -T

YPE

 C5 (

SET

 

OF

 2)

1

1

S97020204-003

G

REASE

 F

ILTER

 - H

YBRID

 -T

YPE

 D5 (

SET

 

OF

 2)

1

1

9

S97020843

B

LOWER

 A

SS

'

Y

 CCW (

INCLUDING

 

ITEMS

 4 

AND

 7 

AND

 

HARDWARE

)

1

1

1

1

10

S97020445

T

RANSFORMER

 24 V 18 VA (

WITH

 

SCREWS

)

1

1

1

1

11

S97020444

LED 

MODULE

 (

PAIR

)

 

1

1

1

1

12

S97020441

I

NFRARED

 S

ENSING

 C

ONTROL

1

1

1

1

*

S97020796

W

IRE

 

HARNESS

 

WITH

 

AUTOTRANSFORMER

 

AND

 

FUSE

1

1

1

1

*

S97020360

P

ARTS

 

BAG

 

INCLUDING

: 4 M

ETAL

 

SCREWS

 

NO

. 8-18 

X

 1/2”, 

4 W

ASHERS

, 6 R

OUND

 

HEAD

 

NO

. 8 

X

 5/8” 

WOOD

 

SCREWS

NO

. 8 

X

 1/2” C

OUNTERSUNK

 

WOOD

 

SCREWS

1

1

1

1

*

S97020466

N

ON

-

DUCTED

 F

ILTER

 - T

YPE

 X

C

 (

PAIR

) (

NON

-

DUCTED

 

INSTALLATION

 

ONLY

)

1

1

*

S97020467

N

ON

-

DUCTED

 F

ILTER

 - T

YPE

 X

D

 (

PAIR

) (

NON

-

DUCTED

 

INSTALLATION

 

ONLY

)

1

1

*

S99527587

N

ON

-D

UCTED

 F

ILTER

 C

LIP

 K

IT

 (

INCL

. 4 

CLIPS

)

1

1

1

1

*

S97020470

E

ASY

 

INSTALL

 

KIT

 (

INCLUDING

 

HARDWARE

)

1

1

1

1

* I

TEM

 

NOT

 

SHOWN

.

R

EPLACEMENT

 P

ARTS

 

AND

 R

EPAIRS

In order to ensure your unit remains in good working condition, you must use Venmar Ventilation ULC genuine replacement parts 
only. Venmar Ventilation ULC genuine replacement parts are specially designed for each unit and are manufactured to comply with 
all the applicable certification standards and maintain a high standard of safety. Any third party replacement part used may cause 
serious damage and drastically reduce the performance level of your unit, which will result in premature failing. Venmar Ventilation ULC 
recommends to contact a certified service depot for all replacement parts and repairs.

B

L

C

D

E

F

G

H

I

J

K

M

Summary of Contents for VCQLA1 Series

Page 1: ...WWW VENMAR CA Serial number 99045657 005A WWW VENMAR CA RANGE HOOD Series VCQLA1 INSTALLATION USE AND CARE MANUAL...

Page 2: ...ing Installation 8 20 Recommended Tools and Accessories for Installation 8 Install Ductwork Ducted Installations Only 8 Contents 9 Prepare the Hood 10 12 Prepare the Hood Location 13 EZ1 Person Instal...

Page 3: ...fficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guidelines a...

Page 4: ...nd you know how to operate it B The fire is small and contained in the area where it started C The fire department has been called D You can fight the fire with your back to an exit Based on Kitchen F...

Page 5: ...beep will be emitted at the first touch and again at the end of the 3 second hold The blower will continue to operate for 10 minutes at this setting During this time the sensor corresponding to the ac...

Page 6: ...lighting and lasting up to 25 times as long as a standard bulb While they are available as service parts these modules are designed to last the life of the hood FILTER CLEANING REMINDER When it is tim...

Page 7: ...WHEELS The center of the fan wheels should be cleaned frequently Use a clean cloth soaked with warm detergent solution STAINLESS STEEL CLEANING Do Regularly wash with clean cloth or rag soaked with w...

Page 8: ...e hood Install Ductwork Ducted Installations Only SOFFIT 18 MIN 24 MAX ABOVE COOKING SURFACE CABINET 3 X 10 DUCT FOR HORIZONTAL DISCHARGE WALL CAP ROOF CAP 3 X 10 OR 7 ROUND DUCT FOR VERTICAL DISCHARG...

Page 9: ...puyer ce bord au mur arri re Utiliser ce gabarit pour marquer vos rep res ne pas tenter de d couper le trou pour le conduit travers le gabarit NOTE Les d coupes incluent le jeu n cessaire l installati...

Page 10: ...ger cup remove the grease filters from the hood by pushing down and tilting filters out 7 ROUND DUCT PLATE 2 SCREWS 1 2 3 4 5 6 7 4 Using a 11 32 nutdriver or socket remove the lock nut retaining the...

Page 11: ...Remove the parts bag taped on the inner back of hood near the left corner Remove the EZ1 brackets from inside the hood by cutting off the tie wrap Discard the tie wrap 6 Remove Electrical Power Cable...

Page 12: ...ter ductwork the 7 round duct plate can be installed up to 1 2 on either side of the hood center 7 ROUND KNOCKOUT PLATE ALSO REMOVE 3 X 10 VERTICAL KNOCKOUT PLATE 3 X 10 VERTICAL KNOCKOUT PLATE 3 X 10...

Page 13: ...10 3 x 14 RECTANGULAR DUCTING 7 ROUND DUCTING OR Use this template for marking do not attempt to cut out the ducting hole through it NOTE These cutouts are clearance holes they do not need to be the e...

Page 14: ...ws Repeat for the other side frame 7 Install the proper installation brackets according to the type of cabinet framed or frameless See below 4 Drill a 1 8 dia pilot hole for house wiring at B location...

Page 15: ...ine on the outer edge of the bracket as shown Slide the bracket towards the center of cabinet and align outside edge of the bracket to marked line keeping the rear end edge leaning on the wall Use a p...

Page 16: ...REAR HOLES A and B While holding the hood run the house power cable into the hood through the strain relief previously installed in step 6 on page 11 4 Unhook the rear holes from the brackets and han...

Page 17: ...s per side in the slots as shown in insets on illustration below 8 For frameless cabinet secure the hood to the cabinet using four 4 no 8 x 5 8 round head wood screws screws and washers included in pa...

Page 18: ...ACCESS HOLE 5 5 CENTER LINE ELECTRICAL ACCESS HOLE IN CABINET BOTTOM WOOD SHIMS RECESSED BOTTOM CABINETS ONLY CABINET FRONT 3 4 1 1 9 47 16 CABINET BOTTOM REAR HOOD MOUNTING SCREWS 2 12 30 HOOD 15 36...

Page 19: ...g screw heads are engaged in narrow end of keyhole slots in top of hood Tighten screws securely and maintain a hold on the hood until completing step 3 3 Secure the hood to the cabinet using two 2 no...

Page 20: ...on page 10 Pay attention to screw 1 location from back of hood point of view it must be located on left side of the lock nut see inset WARNING Risk of electric shock Electrical wiring must be done by...

Page 21: ...se filters removed in step 3 page 10 under Prepare the Hood Non ducted Installation Only Purchase two non ducted filters from your local distributor or retailer see product specification label for fil...

Page 22: ...High W J8 1 2 3 4 5 3 4 5 6 7 1 2 1 2 3 4 5 3 2 1 4 Control Board W BK G Y W PP W BK BK BK BK W Fuse 5A 2 3 4 5 1 1 2 3 4 5 BK O 120 BL 88 PP 60 PN 45 Y 10 W W 5 4 3 2 1 6 User interface 1 2 1 2 3 4...

Page 23: ...SS WITH AUTOTRANSFORMER AND FUSE 1 1 1 1 S97020360 PARTS BAG INCLUDING 4 METAL SCREWS NO 8 18 X 1 2 4 WASHERS 6 ROUND HEAD NO 8 X 5 8 WOOD SCREWS 6 NO 8 X 1 2 COUNTERSUNK WOOD SCREWS 1 1 1 1 S97020466...

Page 24: ...ct or replacement parts to you at no charge You are responsible for all costs for removal reinstallation and shipping insurance or other freight charges incurred in the shipment of the Product or part...

Reviews: