background image

INST
ALLA
TION MANUAL

INST
ALLA

TION

13

Prepare the Hood Location

NOTE: Before starting installation, read all the steps of these instructions.
Use the illustration below to identify your kitchen cabinet type.

EZ1 one-person installation system

EZ1 installation is designed for use with kitchen cabinets that have the same width designation as 
the range hood width. If the cabinet is greater than 1/2” wider than the range hood width, please 
use the standard installation method.

1 ] 

Use the proper template for vertical OR horizontal disharge (included) for placement of 
ductwork and electrical cutout in cabinet or wall. For a non-ducted installation, DO NOT cut a 
duct access hole, only cut the hole for electrical wiring. 

If replacing a hood and plan to use 

the existing duct and electrical, steps 2 to 5 may not be necessary. If so, skip to step 6.

2 ]  

Measure and mark the hood center line on cabinet bottom.

3 ]  

Align the center line on template with the hood center line marked on the bottom of the 
cabinet, placing the edge (where indicated) of the template against back wall. When using 
with framed cabinet for vertical exhaust installation, fold over rear edge of template equal 
to the depth of the cabinet frame at the wall (use graduations on template, 

C

 locations on 

template). Tape the template in place.

 

NOTE: When facing the installation, 

A

 and 

B

 (on template) must be at right.

CABINET FRONT

C

L

A

B

Apoyar este borde contra la pared de atrás

Place this edge against back wall

VERTICAL EXHAUST

A

S

A

A

V

RTICAL EX

= 3¼” x 10”

= 3¼” x 14”

R

ECTANGULAR

 D

UCTING

7” R

OUND

 D

UCTING

OR

Use this template for marking;  do not attempt to cut out the ducting hole through it.
NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting.

= 3¼ po x 10 po

= 3¼ po x 14 po

C

ONDUIT

 

RECTANGULAIRE

C

ONDUIT

 

ROND

 

DE

 7 

PO

OU

= 3¼ pulg. x 10 pulg.

= 3¼ pulg. x 14 pulg.

C

ONDUCTO

 

RECTANGULAR

C

ONDUCTO

 

REDONDO

DE

 7 

PULG

.

O

Appuyer ce bord au mur arrière

Utiliser ce gabarit pour marquer vos repères;  ne pas tenter de découper
le trou pour le conduit à travers le gabarit.
NOTE : Les découpes incluent le jeu nécessaire à l’installation; elles ne doivent pas
 

être du format exact des conduits.

Use esta plantilla para crear marcados;  no trate de cortar el
agujero del conducto a través de la plantilla.

NOTA: To be translated in Spanish.

M

ARK

 

WHERE

 

INDICATED

 

FOR

 

THE

 

APPROPRIATE

 

SIZE

 

DUCT

 

OPENING

M

ARQUER

 

LES

 

REPÈRES

 

AUX

 

ENDROITS

 

INDIQUÉS

 

SELON

 

LE

 

FORMAT

 

DE

 

CONDUIT

 

UTILISÉ

T

ITLE

 

TO

 

BE

 

TRANSLATED

 

IN

 S

PANISH

Electrical access hole center

A

 = single blower hood

B

 = double blower hood

Centre du trou pour fil
d’alimentation électrique

A

 = hotte ventilateur simple

B

 = hotte ventilateur double

To be translated in Spanish
Electrical access hole center

A

 = single blower hood

B

 = double blower hood

4¼”

10½”

14½”

8”

7½”

C

C

C

Bend template along graduated
scale when installing to framed
cabinet.

Pour une installation sous une
armoire à fond en retrait, utiliser les
lignes pour mesurer l’épaisseur du
décalage causé par le mur de 
l’armoire et plier le gabarit en 
conséquence.

To be translated in Spanish.

P

C

CABINET FRONT

C

L

A

B

VERTICAL EXHAUST

A

S

A

A

V

RTICAL EX

= 3¼” x 10”

= 3¼” x 14”

R

ECTANGULAR

 D

UCTING

7” R

OUND

 D

UCTING

OR

Use this template for marking;  do not attempt to cut out the ducting hole through it.
NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting.

= 3¼ po x 10 po

= 3¼ po x 14 po

C

ONDUIT

 

RECTANGULAIRE

C

ONDUIT

 

ROND

 

DE

 7 

PO

OU

= 3¼ pulg. x 10 pulg.

= 3¼ pulg. x 14 pulg.

C

ONDUCTO

 

RECTANGULAR

C

ONDUCTO

 

REDONDO

DE

 7 

PULG

.

O

Utiliser ce gabarit pour marquer vos repères;  ne pas tenter de découper
le trou pour le conduit à travers le gabarit.
NOTE : Les découpes incluent le jeu nécessaire à l’installation; elles ne doivent pas
 

être du format exact des conduits.

Use esta plantilla para crear marcados;  no trate de cortar el
agujero del conducto a través de la plantilla.

NOTA: To be translated in Spanish.

M

ARK

 

WHERE

 

INDICATED

 

FOR

 

THE

 

APPROPRIATE

 

SIZE

 

DUCT

 

OPENING

M

ARQUER

 

LES

 

REPÈRES

 

AUX

 

ENDROITS

 

INDIQUÉS

 

SELON

 

LE

 

FORMAT

 

DE

 

CONDUIT

 

UTILISÉ

T

ITLE

 

TO

 

BE

 

TRANSLATED

 

IN

 S

PANISH

Electrical access hole center

A

 = single blower hood

B

 = double blower hood

Centre du trou pour fil
d’alimentation électrique

A

 = hotte ventilateur simple

B

 = hotte ventilateur double

To be translated in Spanish
Electrical access hole center

A

 = single blower hood

B

 = double blower hood

4¼”

10½”

14½”

8”

7½”

C

C

C

Bend template along graduated
scale when installing to framed
cabinet.

Pour une installation sous une
armoire à fond en retrait, utiliser les
lignes pour mesurer l’épaisseur du
décalage causé par le mur de 
l’armoire et plier le gabarit en 
conséquence.

To be translated in Spanish.

ELECTRICAL

ACCESS HOLE

LOCATION (

B

)

(

IN

 

CABINET

 

BOTTOM

)

CENTER LINE

F

OLD

 

TEMPLATE

 

ALONG

 

GRADUATED

SCALE

 

WHEN

 

INSTALLING

 

TO

 

FRAMED

CABINET

.

B

VERTICAL EXHAUST 

DUCTING

ELECTRICAL

ACCESS HOLE

LOCATION (

B

)

(

IN

 

WALL

)

CENTER LINE

C

L

A

B

Place this edge against
cabinet bottom.
Appuyer ce bord contre le bas
de l’armoire.
Apoyar este borde contra
la base del armario.

HORIZONTAL EXHAUST

T

T

= 3¼ pulg. x 10 pulg.
= 3¼ pulg. x 14 pulg.

CONDUCTO RECTANGULAR

= 3¼” x 10”
= 3¼” x 14”

RECTANGULAR DUCTING

= 3¼ po x 10 po
= 3¼ po x 14 po

CONDUIT RECTANGULAIRE

MARK WHERE INDICATED 

FOR

 THE APPROPRIATE SIZE DUCT OPENING

MARQUER LES REPÈRES AUX ENDROITS INDIQUÉS SELON 

LE

 FORMAT DE CONDUIT UTILISÉ

TITLE TO BE TRANSLATED IN SPANISH

Use this template for marking;  do not attempt to cut out the ducting hole through it.
NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting.

Utiliser ce gabarit pour marquer vos repères;  ne pas tenter de découper
le trou pour le conduit à travers le gabarit.
NOTE : Les découpes incluent le jeu nécessaire à l’installation; elles ne doivent pas
 

être du format exact des conduits.

Use esta plantilla para crear marcados;  no trate de cortar el
agujero del conducto a través de la plantilla.
NOTA: To be translated in Spanish.

Electrical access hole center

A

 = single blower hood

B

 = double blower hood

Centre du trou pour fil
d’alimentation électrique

A

 = hotte ventilateur simple

B

 = hotte ventilateur double

To be translated in Spanish
Electrical access hole center

A

 = single blower hood

B

 = double blower hood

B

ess hole center
wer hood
wer hood

HORIZONTAL EXHAUST 

DUCTING

This manual covers 2 kinds of installation: the standard (without EZ1 brackets) 
and the EZ1 one-person installation system (using included template and brackets).
For the standard installation, go to page 18.

FRAMED CABINET

FRAMELESS CABINET

Summary of Contents for VCQLA1 Series

Page 1: ...WWW VENMAR CA Serial number 99045657 005A WWW VENMAR CA RANGE HOOD Series VCQLA1 INSTALLATION USE AND CARE MANUAL...

Page 2: ...ing Installation 8 20 Recommended Tools and Accessories for Installation 8 Install Ductwork Ducted Installations Only 8 Contents 9 Prepare the Hood 10 12 Prepare the Hood Location 13 EZ1 Person Instal...

Page 3: ...fficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guidelines a...

Page 4: ...nd you know how to operate it B The fire is small and contained in the area where it started C The fire department has been called D You can fight the fire with your back to an exit Based on Kitchen F...

Page 5: ...beep will be emitted at the first touch and again at the end of the 3 second hold The blower will continue to operate for 10 minutes at this setting During this time the sensor corresponding to the ac...

Page 6: ...lighting and lasting up to 25 times as long as a standard bulb While they are available as service parts these modules are designed to last the life of the hood FILTER CLEANING REMINDER When it is tim...

Page 7: ...WHEELS The center of the fan wheels should be cleaned frequently Use a clean cloth soaked with warm detergent solution STAINLESS STEEL CLEANING Do Regularly wash with clean cloth or rag soaked with w...

Page 8: ...e hood Install Ductwork Ducted Installations Only SOFFIT 18 MIN 24 MAX ABOVE COOKING SURFACE CABINET 3 X 10 DUCT FOR HORIZONTAL DISCHARGE WALL CAP ROOF CAP 3 X 10 OR 7 ROUND DUCT FOR VERTICAL DISCHARG...

Page 9: ...puyer ce bord au mur arri re Utiliser ce gabarit pour marquer vos rep res ne pas tenter de d couper le trou pour le conduit travers le gabarit NOTE Les d coupes incluent le jeu n cessaire l installati...

Page 10: ...ger cup remove the grease filters from the hood by pushing down and tilting filters out 7 ROUND DUCT PLATE 2 SCREWS 1 2 3 4 5 6 7 4 Using a 11 32 nutdriver or socket remove the lock nut retaining the...

Page 11: ...Remove the parts bag taped on the inner back of hood near the left corner Remove the EZ1 brackets from inside the hood by cutting off the tie wrap Discard the tie wrap 6 Remove Electrical Power Cable...

Page 12: ...ter ductwork the 7 round duct plate can be installed up to 1 2 on either side of the hood center 7 ROUND KNOCKOUT PLATE ALSO REMOVE 3 X 10 VERTICAL KNOCKOUT PLATE 3 X 10 VERTICAL KNOCKOUT PLATE 3 X 10...

Page 13: ...10 3 x 14 RECTANGULAR DUCTING 7 ROUND DUCTING OR Use this template for marking do not attempt to cut out the ducting hole through it NOTE These cutouts are clearance holes they do not need to be the e...

Page 14: ...ws Repeat for the other side frame 7 Install the proper installation brackets according to the type of cabinet framed or frameless See below 4 Drill a 1 8 dia pilot hole for house wiring at B location...

Page 15: ...ine on the outer edge of the bracket as shown Slide the bracket towards the center of cabinet and align outside edge of the bracket to marked line keeping the rear end edge leaning on the wall Use a p...

Page 16: ...REAR HOLES A and B While holding the hood run the house power cable into the hood through the strain relief previously installed in step 6 on page 11 4 Unhook the rear holes from the brackets and han...

Page 17: ...s per side in the slots as shown in insets on illustration below 8 For frameless cabinet secure the hood to the cabinet using four 4 no 8 x 5 8 round head wood screws screws and washers included in pa...

Page 18: ...ACCESS HOLE 5 5 CENTER LINE ELECTRICAL ACCESS HOLE IN CABINET BOTTOM WOOD SHIMS RECESSED BOTTOM CABINETS ONLY CABINET FRONT 3 4 1 1 9 47 16 CABINET BOTTOM REAR HOOD MOUNTING SCREWS 2 12 30 HOOD 15 36...

Page 19: ...g screw heads are engaged in narrow end of keyhole slots in top of hood Tighten screws securely and maintain a hold on the hood until completing step 3 3 Secure the hood to the cabinet using two 2 no...

Page 20: ...on page 10 Pay attention to screw 1 location from back of hood point of view it must be located on left side of the lock nut see inset WARNING Risk of electric shock Electrical wiring must be done by...

Page 21: ...se filters removed in step 3 page 10 under Prepare the Hood Non ducted Installation Only Purchase two non ducted filters from your local distributor or retailer see product specification label for fil...

Page 22: ...High W J8 1 2 3 4 5 3 4 5 6 7 1 2 1 2 3 4 5 3 2 1 4 Control Board W BK G Y W PP W BK BK BK BK W Fuse 5A 2 3 4 5 1 1 2 3 4 5 BK O 120 BL 88 PP 60 PN 45 Y 10 W W 5 4 3 2 1 6 User interface 1 2 1 2 3 4...

Page 23: ...SS WITH AUTOTRANSFORMER AND FUSE 1 1 1 1 S97020360 PARTS BAG INCLUDING 4 METAL SCREWS NO 8 18 X 1 2 4 WASHERS 6 ROUND HEAD NO 8 X 5 8 WOOD SCREWS 6 NO 8 X 1 2 COUNTERSUNK WOOD SCREWS 1 1 1 1 S97020466...

Page 24: ...ct or replacement parts to you at no charge You are responsible for all costs for removal reinstallation and shipping insurance or other freight charges incurred in the shipment of the Product or part...