background image

HO0104

BE CAREFUL when installing the decorative flue and hood, they may have sharp edges.

1. Lay the back side of the hood flat on a table. Use a piece of cardboard to avoid

damaging the table or the hood.

2. Remove the grease filters by pulling down the metal latch tab and tilting filters

downward to remove.

3. Align the hood and center it above the hood mounting bracket. Gently lower the

hood until it securely engages the bracket.

4. With the hood hanging in place, drill through both holes located in the

inside lower back of hood (

Fig. 1

) using a 5/16” drill bit. Insert the included drywall

anchors into the drilled holes (one for each hole). Insert 2 no. 8 x 1¼” mounting
screws in 2 washers (one per washer), then insert into the drywall anchors. Verify
that the hood is centered and leveled. Tighten all screws completely.

5. Reinstall grease filters by aligning rear filter tabs with slots in the hood. Pull down

the metal latch tab, push filter into position and release. Make sure filters are
securely engaged after installation. 

6. Install 6” round adapter/damper on top of the hood using 4 no. 8 x 7/16” mounting screws.

7. Remove protective plastic film covering the lower flue only.

8. Install the lower flue bracket to its flue using 2 no. 8 x 7/16” mounting screws, make

sure that the slots point up (

Fig. 2

).

9. Carefully place both flues into the recessed area of hood top. Slightly slide up the

upper flue to avoid any damage while placing the lower flue to the hood top.

10. Slide a 6” metal round duct over the adapter/damper (

Fig. 3

). Use metal foil duct

tape to seal the joint. 

11. Plug hood power cord into the outlet.

12. Slide up the upper flue until it is aligned with its mounting bracket. The bracket 

should be inside the flue. Secure the upper flue to its bracket using 
2 no. 8 x 7/16” mounting screws (

Fig. 4

).

13. Remove protective plastic film covering the upper flue and the hood.

14. Mount the glass plate or the stainless steel plate on the top of hood base with 

4 mechanical flat head screws (M4 x 0.7”) and 4 aesthetic washers. Screw from top
of hood base.

7. INSTALL HOOD

CAUTION

DO NOT REMOVE the protective plastic film covering the decorative flue (upper and lower) and the hood yet.

-6-

6

R

OUND

DUCT

HJ0012A

Fig. 3

Fig. 4

HD0255A

H

OLE

S

 

LOCATION

14¼

Ø 5/16

 

TYP

.

M

OTOR

/B

LOWER

A

SS

EMBLY

S

IDE

 

VIEW

I

N

S

IDE

 

BACK

OF

 

THE

 

HOOD

Fig. 1

U

PPER FLUE MOUNTING BRACKET

F

RONT VIEW

U

PPER

FLUE

HO0114

Fig. 2

L

OWER FLUE MOUNTING BRACKET

B

ACK VIEW

L

OWER

FLUE

S

LOTS UP

WARNING

!

Summary of Contents for Jazz VJ604302SS

Page 1: ...THIS MANUAL WITH HOMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGES 7 AND 8 Venmar Ventilation Inc 550 Lemire Blvd Drummondville QC J2C 7W9 1 800 567 3855 REGISTER YOUR PRODUCT ON LINE AT www bnv c...

Page 2: ...ette Cherries Jubilee Peppercorn Beef Flamb c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter d Use proper pan size Always use cookware appropriate for th...

Page 3: ...es To reduce the risk of fire use only metal ductwork 2 MEASURE INSTALLATION The minimum hood distance above cooktop MUST NOT BE less than 26 A maximum of 30 above cooktop is highly recommended for be...

Page 4: ...ce before wiring HE0086 Improper grounding can result in a risk of electric shock Consult a qualified electrician if the grounding instructions are not completely understood or if doubt exists as to w...

Page 5: ...er hidden utilities 6 INSTALL UPPER FLUE MOUNTING BRACKET Center the bracket over the hood location and place it flush with the ceiling Make sure that the slots of the upper flue bracket point down Us...

Page 6: ...ove protective plastic film covering the lower flue only 8 Install the lower flue bracket to its flue using 2 no 8 x 7 16 mounting screws make sure that the slots point up Fig 2 9 Carefully place both...

Page 7: ...57 WARNING In order to prevent the risk of personal injury the halogen lamps must be cooled down before removing them CAUTION Do not touch replacement bulb with bare hands LIGHT BULB COVER 1 To remove...

Page 8: ...10 OPERATION continued 1 TIME DELAY 2 Functions Time Setting This button is used to set time when lighting and blower are not in use Time is displayed in 24 hour cycle To set time press the push butto...

Page 9: ...drywall anchors 2 washers 2 no 8 x 1 mounting screws 4 aesthetic washers 4 M4 x 0 7 mechanical flat head screws 1 9 Not illustrated HL0128 7 1 2 3 4 3 5 6 REPLACEMENT PARTS AND REPAIRS In order to en...

Page 10: ...ice provider offers service If in home service is not available the product will be repaired or replaced at Venmar Ventilation Inc s discretion by the nearest authorized service provider The unit remo...

Reviews: