Venmar Jazz VJ604302SS Installation Manual Download Page 7

8. GREASE FILTERS

-7-

9. LIGHT BULBS

10.OPERATION

This range hood requires two UL approved halogen bulbs 
(Type JC, 12 V, 20 W Maximum, G-4 Base).

To change bulbs:
1.

Gently push the rim upward and turn counterclockwise to disengage
the light bulb cover.

2.

Replace with Type JC, 12V, 20 W Maximum, G-4 Base halogen
bulb. 

3.

Replace the light bulb cover by pushing the rim upward and rotating
the light bulb cover clockwise. 

WARNING

Always switch off the electrical supply before carrying out
any operation on the appliance.

!

HD0257

WARNING

In order to prevent the risk of personal injury, the halogen
lamps must be cooled down before removing them.

CAUTION

Do not touch replacement bulb with bare hands!

!

L

IGHT BULB COVER

1.

To remove the grease filters, pull down on the metal latch tab and
tilt each filter downward to remove.

2.

To install the grease filters, align rear filter tabs with slots in the
hood. Pull down the metal latch tab, push each filter into position
and release. Make sure filters are securely engaged after 
installation.

HD0256

Lamp

Power

Speed

HC004

8

Timer

1

1) Time/Delay push button

3) Blower push button

2) Lighting push button

4) ON/OFF push button

2

3

4

The hood is operated using the push buttons located on the front panel.

Summary of Contents for Jazz VJ604302SS

Page 1: ...THIS MANUAL WITH HOMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGES 7 AND 8 Venmar Ventilation Inc 550 Lemire Blvd Drummondville QC J2C 7W9 1 800 567 3855 REGISTER YOUR PRODUCT ON LINE AT www bnv c...

Page 2: ...ette Cherries Jubilee Peppercorn Beef Flamb c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter d Use proper pan size Always use cookware appropriate for th...

Page 3: ...es To reduce the risk of fire use only metal ductwork 2 MEASURE INSTALLATION The minimum hood distance above cooktop MUST NOT BE less than 26 A maximum of 30 above cooktop is highly recommended for be...

Page 4: ...ce before wiring HE0086 Improper grounding can result in a risk of electric shock Consult a qualified electrician if the grounding instructions are not completely understood or if doubt exists as to w...

Page 5: ...er hidden utilities 6 INSTALL UPPER FLUE MOUNTING BRACKET Center the bracket over the hood location and place it flush with the ceiling Make sure that the slots of the upper flue bracket point down Us...

Page 6: ...ove protective plastic film covering the lower flue only 8 Install the lower flue bracket to its flue using 2 no 8 x 7 16 mounting screws make sure that the slots point up Fig 2 9 Carefully place both...

Page 7: ...57 WARNING In order to prevent the risk of personal injury the halogen lamps must be cooled down before removing them CAUTION Do not touch replacement bulb with bare hands LIGHT BULB COVER 1 To remove...

Page 8: ...10 OPERATION continued 1 TIME DELAY 2 Functions Time Setting This button is used to set time when lighting and blower are not in use Time is displayed in 24 hour cycle To set time press the push butto...

Page 9: ...drywall anchors 2 washers 2 no 8 x 1 mounting screws 4 aesthetic washers 4 M4 x 0 7 mechanical flat head screws 1 9 Not illustrated HL0128 7 1 2 3 4 3 5 6 REPLACEMENT PARTS AND REPAIRS In order to en...

Page 10: ...ice provider offers service If in home service is not available the product will be repaired or replaced at Venmar Ventilation Inc s discretion by the nearest authorized service provider The unit remo...

Reviews: