Venmar HO50200 User Manual Download Page 3

3

4

3

TOOLS

2 5/8

VENMAR

1

2

3

F

1 • 2 • 3 • O

0 • 5 min.

5 1/2

3

9 7/8

10

20

163

°

3

2 1/2

2 1/4

1 5/8

10 3/4

29 7/8

24 1/2

21

VENMAR

1

2

3

F

1 • 2 • 3 • O

0 • 5 min.

 7/8

2 3/8

4 3/8

20

10

1 5/8

10 3/4

2 5/8

2 1/4

2 1/2

163

°

3

21

24 1/2

29 7/8

HO5XXXX   -   

29 

7

/

HO6XXXX   -  

35 

7

/

HO5XXXX   -   

29 

7

/

HO6XXXX   -  

35 

7

/

TOOLS NEEDED TO INSTALL THE RANGE HOOD

- Philips screwdriver #2 or square #1.
- Hammer (To open the knockout hole and the exhaust port).
- Sheet metal shears (to make duct adjustments).
- Pair of pliers (to make duct adjustments).

Caution:

To reduce fire hazard and to properly exhaust stale air, be sure to duct air out-
side or recirculate the air with the HO 50950 charcoal unit.  The exhaust port
must never lead into a chimney used to exhaust gases or smoke.  Do not
exhaust stale air into spaces in walls, ceilings, attics, crawl spaces or garages.

Warning:

The heating element of the range and the underside of the

hood must be, at least 20" (50cm) apart. Over a gas range, the dis-
tance must be increased to, at least, 24” (60 cm).

If the bottom of the cupboard is recessed, attach three wood
strips as shown to be able to screw the range hood under the
cabinet.

Remove the screw on the bottom of the hood and remove the cover.
* Be careful not to touch the electronic board.

Determine if the exhaust hole is on the top (3a) or rear (3b) of
the range hood. Disconnect the appropriate stale air outlet
using a hammer and screwdriver.
The best circular transition to a 3-1/4” x 10” (8.25 cm x 25.4 cm)
rectangular tubing measures 6” (15.24 cm) diameter. For better
Venmar Ventilation performance, it is recommended to follow
this instruction.

NOTE 

We recommend that the wall duct be well prepared to receive

the adaptor. Make sure that the adaptor fits easily in the duct before
doing the installation. The use of the adaptor is strongly recommend-
ed for better performance of your unit. If you purchase the Venmar
hood to replace another hood and you use the top outlet, please
note that location of the exhaust duct can vary from one manufac-
turer to another.

4

INSTALLATION OF THE HOOD WITH EXTERIOR OUTLET

3

1

a)

VENMAR

1

2

3

F

1 ¥ 2 ¥ 3 ¥ O

0 ¥ 5 min.

VENTILATION in

c.

2

b)

1

2

3

Summary of Contents for HO50200

Page 1: ...the warranty section If your unit is defective contact the Venmar Ventilation Service Department at the following toll free numbers 1 800 567 3855 from Canada and 1 800 836 6271 from United States N...

Page 2: ...T USE WATER including wet dishcloths or towels A violent steam explosion will result D Use an extinguisher ONLY if 1 You know you have a Class ABC extinguisher and you already know how to operate it 2...

Page 3: ...be increased to at least 24 60 cm If the bottom of the cupboard is recessed attach three wood strips as shown to be able to screw the range hood under the cabinet Remove the screw on the bottom of the...

Page 4: ...e tightening Punch out the power supply hole at the rear or on the top of the range hood depending on the installation Make sure the power supply is on the right side of the hood Insert the electrical...

Page 5: ...eely Install the five screws of the bottom cover using the four additionnal screws available in the installation bag Put the filters back in place 5 INSTALLATION OF THE CHARCOAL UNIT VENMAR 1 2 3 F 1...

Page 6: ...be grounded a The ground lead must be connected to the connector installed on the range hood chassis b The white lead must be connected with the white lead of the power supply neutral c The black lead...

Page 7: ...turn off simultaneously the motor and the lights press the switch once b After 25 hours of operation the filter maintenance light indi cator will turn on This indicates that the intake ring the filter...

Page 8: ...f purchase This warranty includes repair or at our option replacement of any VENMAR RANGE HOOD found to be defective This express warranty will be null and void and of no effect if the function or for...

Reviews: