20. OPERATION (
CONT
’
D
)
- 20 -
A. D
ELAY
B
UTTON
/C
ONTROL
L
OCK
(D
OUBLE
F
UNCTION
B
UTTON
):
i. When a blower speed is selected, press this button to activate the delay function. The delay
button will light to its high intensity, then to its mid intensity to indicate this function is activated;
the selected blower speed button will alternate every 2 seconds from its high intensity to its
mid intensity. The blower will continue to operate for 5 minutes and will stop automatically.
Selecting another speed while the delay function is activated will not deactivate the function
or reset the timer. To cancel the delay function, press the delay button once again or the
selected speed button which last case will also turn the blower off.
ii. When blower is off, it is possible to lock the control interface in order to clean the glass panel.
To lock the control interface: Press and hold the button for 3 seconds. The button will light to
its high intensity and flash three times, it will then stay on its mid intensity to indicate that the
control interface is locked.
To unlock the control interface: Press and hold the button for 3 seconds. The button will light
to its high intensity and flash 3 times, it will then fade out to its low intensity to indicate that
the control interface is unlocked.
B. S
PEED
S
ELECTION
B
UTTONS
:
Press the button corresponding to the desired blower speed (from
1
for low speed to
4
for high
speed). The chosen speed button will light to its high intensity then fade to its mid intensity. To
turn off the blower, press once more on the corresponding blower speed button; the button
light will fade to its low intensity.
NOTE: When blower is off, pressing on blower speed
1
button will cause the blower to start
on second speed for a very short lapse of time, and then resume on speed
1
.
C. M
ASTER
ON/OFF:
When blower and lights are off, press this button to turn the hood on to the last memorized
speed level and light intensity. If there are no memorized speed level and light intensity, speed
will be set at level
1
and light intensity at
4
. To turn off the blower and the light simultaneously,
press this button once.
H
EAT
S
ENTRY
™:
The hood is equipped with a HEAT SENTRY thermostat. When blower is ON
at any speed and excessive heat is detected above the cooking surface, it sets the blower on
third speed. The third speed button backlight will blink quickly to indicate that the Heat Sentry
has been activated. When the temperature level drops to normal, the blower will return to its
original setting.
D. L
IGHT
B
UTTON
/B
ACKLIGHTING
C
OLOR
(D
OUBLE
F
UNCTION
B
UTTON
):
i. This button allows four different lighting levels according to your needs. Press once for full
intensity, twice for intensity level
3
, three times for intensity level
2
and once more for
nightlight. To turn off the lights, press once more.
If desired, when the lights are on, press and maintain the light button for 1 second; lights will
be turned off and the light level in use will be memorized.
NOTE: When only lights are ON to any intensity and no interaction with the hood is detected
for a 10-second period, the 7 buttons backlighting will fade to its low intensity, acting
as a night light feature.
ii. When lights are off, pressing and holding this button for 2 seconds will switch the backlighting
color from white to blue or from blue to white (default backlighting color is white) and memorize
it. The button will flash three times to indicate that the color change has been made.
WARNING
The Heat Sentry can take control of the blower when excessive heat is detect-
ed above the cooking surface. If this situation occurs and you must stop the
blower, press on the third speed button or on the master ON/OFF button.
!
A
B
C
D
HC0052