background image

3

4

1.2

 DESCRIPTION

The product is a control unit to control electrical motors powered from the grid with power of max. 500 W

(230 V) or max. 250 W (110 V).

Ideal for activating motorised awnings, shutters and blinds with settable Up-Down-Stop, step and manual 

modes.

The ISM (industrial, scientific and medical) radio frequency band guarantees a long range, even through walls 

and ceilings. 

Simple programming with dip-switches, reduced dimensions with breakable tabs (pic. 1.1c) for fixing with

screws (pic. 1.2a) or for insertion into connection boxes up to 55 mm in diameter (pic. 1.2b, 1.2c and 1.2d).

1 PRODUCT FEATURES 

43mm

21mm

52mm

Led

Dip switches

Button 

58mm

1.1

 TECHNICAL DATA 

From the grid  120-240 Vac
1 motor powered from the grid: 
230V max 500W,
110V max 250W 
100
433.920MHz ISM
IP20
-20 +55 °C
52x43x21 mm

Power supply 
Outputs 

Num. of programmable transmitters 
Radio frequency 
Protection rating 
Operating temperature
Dimensions

Pic.1.1a

- Installation must be carried out only by qualified technicians in compliance with the electrical and safety 

standards in force. 

- All connections must be made with the power turned off. 

- Use suitable cables. 

- Do not cut through the aerial (see picture 1.1b) 

- A suitably sized disconnection device must be set up on the electric power line that supplies the product. 

- Disposal of waste materials must fully respect local standards. 

WARNINGS 

Pic.1.1b

Pic.1.1c

Pic.1.2a

Pic.1.2b

Pic.1.2c

Pic.1.2d

Pic.1.2e

L

N

M

Summary of Contents for VELA-RX

Page 1: ...VELA RX MOTORE 220V 500W Electronic control unit with UP DOWN and STOP functions for managing 230 V max 500 W motors via wire and or radio...

Page 2: ...1...

Page 3: ...ION 2 ELECTRICAL CONNECTIONS 2 1 CONNECTION DIAGRAM 3 USE OF THE CONTROL UNIT 3 1 USE VIA RADIO 3 2 USE VIA WIRE 4 CONTROL UNIT SETTINGS 4 1 CONFIGURATION OF BUTTONS VIA WIRE 4 2 CONFIGURATION OF MANO...

Page 4: ...rating Operating temperature Dimensions Pic 1 1a Installation must be carried out only by qualified technicians in compliance with the electrical and safety standards in force All connections must be...

Page 5: ...ttable Up Down Stop step and manual modes The ISM industrial scientific and medical radio frequency band guarantees a long range even through walls and ceilings Simple programming with dip switches re...

Page 6: ...tiple buttons or loads can be connected by using parallel cabling If the condenser is not connected internally to the motor typical of tubular motors it is connected between the phases terminals 4 and...

Page 7: ...n stop device 3 1 USE VIA RADIO The device is set up to be able to accept commands via wire from buttons in terminals 3 and 4 Should you wish to control the load only via radio it is not necessary to...

Page 8: ...t time count the number of flashes emitted by the LED 6 flashes MODE 1 P1 P2 pen stop close stop 3 flashes MODE 2 P1 Open stop P2 Close stop SHORT PRESSURE SHORT PRESSURE DIP 4 ON DIP 4 OFF PULSE OPER...

Page 9: ...P 1 2 3 OFF OFF OFF STEP 2 Press the button on the receiver for a short time The LED comes on and stays on STEP 3 Press the button on the receiver for a short time The LED flashes max 180 flashes each...

Page 10: ...multifunctional transmitters the transmitter control modes depend on the model used Refer to the transmitter manual to the paragraph entitled commands sent by the transmitter bearing in mind that it i...

Page 11: ...TRANSMITTER see models and codes on previous page GENERIC TRANSMITTER see models and codes on previous page WHICH TRANSMITTER DO YOU WANT TO PROGRAMME STEP 1a Position DIPs 1 2 and 3 to ON ON ON DIP 1...

Page 12: ...er that you want to delete The LED flashes quickly and turns off MAKE A TRANSMISSION WITH THE TRANSMITTER LED FLASHES QUICKLY LONG PRESSURE 8 SECONDS STEP 1 Hold the receiver button down for 8 seconds...

Page 13: ...12...

Page 14: ......

Page 15: ......

Page 16: ...V1 0...

Reviews: