background image

Default: 60 seconds

This procedure is used to set the opening and closing manoeuvre time (maximum time that can be set 3 

minutes).

PROCEDURE:

4.2

 CONFIGURATION OF MANOEUVRE TIMES

STEP 1

Position DIPs 1, 2 and 3

to OFF-OFF-OFF

DIP 1, 2, 3=

OFF OFF OFF

STEP 2

Press the button on the

receiver for a short time. 

The LED comes on

and stays on

STEP 3

Press the button on the

receiver for a short time. 

The LED flashes

(max 180 flashes):

each flash represents a 

second of manoeuvring

SHORT

PRESSURE

SHORT

PRESSURE

SHORT PRESSURE

DURING THE FLASH

STEP 4

To end the count press

the button for a

short time during the

flash that corresponds

to the function desired

Default: mode 1

This procedure lets you select the function of inputs "P1" (terminal 3) and "P2" (terminal 4). WARNING: the 

connected devices must be buttons.

PROCEDURE:

CONTROL MODES:

4.1

 CONFIGURATION OF BUTTONS VIA WIRE

STEP 1

Position DIPs 1, 2 and 3

to OFF-ON-OFF

DIP 1, 2, 3=

OFF ON OFF

STEP 2

Press the button on the

receiver for a short time. 

The LED comes on

and stays on

STEP 3

Press the button on the receiver for a short time

count the number of flashes emitted by the LED:

6 flashes = MODE 1 (P1=P2= pen/stop/close/stop) 

3 flashes = MODE 2 (P1= Open/stop P2= Close/stop)

SHORT

PRESSURE

SHORT

PRESSURE

DIP 4 =

ON

DIP 4 =

OFF

PULSE OPERATION

An action of the motor

corresponds to each short 

pressure

of the key

MANUAL OPERATION

The movements of the motor 

occur only with the key 

pressed down, when it is 

released the control unit 

carries out a stop

STEP 4

To change the setting, repeat the procedure from 

point 1; the control unit will alternate between

3 and 6 flashes.

NUMBER OF  TYPE OF  

FLASH  

INPUT

3  

 

mono-button

6   bi-button

4  CONTROL UNIT SETTINGS

7

8

Summary of Contents for VELA-RX

Page 1: ...VELA RX MOTORE 220V 500W Electronic control unit with UP DOWN and STOP functions for managing 230 V max 500 W motors via wire and or radio...

Page 2: ...1...

Page 3: ...ION 2 ELECTRICAL CONNECTIONS 2 1 CONNECTION DIAGRAM 3 USE OF THE CONTROL UNIT 3 1 USE VIA RADIO 3 2 USE VIA WIRE 4 CONTROL UNIT SETTINGS 4 1 CONFIGURATION OF BUTTONS VIA WIRE 4 2 CONFIGURATION OF MANO...

Page 4: ...rating Operating temperature Dimensions Pic 1 1a Installation must be carried out only by qualified technicians in compliance with the electrical and safety standards in force All connections must be...

Page 5: ...ttable Up Down Stop step and manual modes The ISM industrial scientific and medical radio frequency band guarantees a long range even through walls and ceilings Simple programming with dip switches re...

Page 6: ...tiple buttons or loads can be connected by using parallel cabling If the condenser is not connected internally to the motor typical of tubular motors it is connected between the phases terminals 4 and...

Page 7: ...n stop device 3 1 USE VIA RADIO The device is set up to be able to accept commands via wire from buttons in terminals 3 and 4 Should you wish to control the load only via radio it is not necessary to...

Page 8: ...t time count the number of flashes emitted by the LED 6 flashes MODE 1 P1 P2 pen stop close stop 3 flashes MODE 2 P1 Open stop P2 Close stop SHORT PRESSURE SHORT PRESSURE DIP 4 ON DIP 4 OFF PULSE OPER...

Page 9: ...P 1 2 3 OFF OFF OFF STEP 2 Press the button on the receiver for a short time The LED comes on and stays on STEP 3 Press the button on the receiver for a short time The LED flashes max 180 flashes each...

Page 10: ...multifunctional transmitters the transmitter control modes depend on the model used Refer to the transmitter manual to the paragraph entitled commands sent by the transmitter bearing in mind that it i...

Page 11: ...TRANSMITTER see models and codes on previous page GENERIC TRANSMITTER see models and codes on previous page WHICH TRANSMITTER DO YOU WANT TO PROGRAMME STEP 1a Position DIPs 1 2 and 3 to ON ON ON DIP 1...

Page 12: ...er that you want to delete The LED flashes quickly and turns off MAKE A TRANSMISSION WITH THE TRANSMITTER LED FLASHES QUICKLY LONG PRESSURE 8 SECONDS STEP 1 Hold the receiver button down for 8 seconds...

Page 13: ...12...

Page 14: ......

Page 15: ......

Page 16: ...V1 0...

Reviews: