Default: 60 seconds
This procedure is used to set the opening and closing manoeuvre time (maximum time that can be set 3
minutes).
PROCEDURE:
4.2
CONFIGURATION OF MANOEUVRE TIMES
STEP 1
Position DIPs 1, 2 and 3
to OFF-OFF-OFF
DIP 1, 2, 3=
OFF OFF OFF
STEP 2
Press the button on the
receiver for a short time.
The LED comes on
and stays on
STEP 3
Press the button on the
receiver for a short time.
The LED flashes
(max 180 flashes):
each flash represents a
second of manoeuvring
SHORT
PRESSURE
SHORT
PRESSURE
SHORT PRESSURE
DURING THE FLASH
STEP 4
To end the count press
the button for a
short time during the
flash that corresponds
to the function desired
Default: mode 1
This procedure lets you select the function of inputs "P1" (terminal 3) and "P2" (terminal 4). WARNING: the
connected devices must be buttons.
PROCEDURE:
CONTROL MODES:
4.1
CONFIGURATION OF BUTTONS VIA WIRE
STEP 1
Position DIPs 1, 2 and 3
to OFF-ON-OFF
DIP 1, 2, 3=
OFF ON OFF
STEP 2
Press the button on the
receiver for a short time.
The LED comes on
and stays on
STEP 3
Press the button on the receiver for a short time
count the number of flashes emitted by the LED:
6 flashes = MODE 1 (P1=P2= pen/stop/close/stop)
3 flashes = MODE 2 (P1= Open/stop P2= Close/stop)
SHORT
PRESSURE
SHORT
PRESSURE
DIP 4 =
ON
DIP 4 =
OFF
PULSE OPERATION
An action of the motor
corresponds to each short
pressure
of the key
MANUAL OPERATION
The movements of the motor
occur only with the key
pressed down, when it is
released the control unit
carries out a stop
STEP 4
To change the setting, repeat the procedure from
point 1; the control unit will alternate between
3 and 6 flashes.
NUMBER OF TYPE OF
FLASH
INPUT
3
mono-button
6 bi-button
4 CONTROL UNIT SETTINGS
7
8