Venini VGH60 Instructions And Installation  User Manual Download Page 8

8

5) GAS CONNECTION

The gas connection is located in the rear and on the
underside  of  the  appliance  100  mm  from  the  right
hand side.

A. 

The cooktop can be connected with rigid pipe as

specified in AS5601 table 3.1.

B. 

If  installing  with  a  hose  assembly,  install  with  a

hose  assembly  that  complies  with AS/ANZ  1869
(AGA Approved),  10mm  ID,  class  B  or  D,  no  more
than  1.2m  long  and  in  accordance  with AS5601.
Ensure  that  the  hose  does  not  contact  the  hot
surfaces  of  the  cooktop,  oven,  dishwasher  or  any
other appliance that may be installed underneath or
next  to  the  cooktop.  The  hose  should  not  be
subjected  to  abrasion,  kinking  or  permanent
deformation  and  should  be  able  to  be  inspected
along  its  entire  length  with  the  cooktop  in  the
installed position.
Unions  compatible  with  the  hose  fittings  must  be
used and all connections tested for gas leaks.

Natural Gas

Natural Gas installations require the connection of
a gas regulator at the appliance. 
Assemble  the  regulator  (noting  the  gas  flow
direction)  and  transition  pieces  (supplied  with  the
appliance), in accordance with figure 12.
The  transition  piece  on  the  supply  side  of  the
regulator must be provided by the installer.

Liquified Petroleum Gas

In a LPG installation the gas regulation is made at
the gas cylinder and regulation at the appliance is
not  required.  To  connect  supply  to  the  appliance
use transition pieces as shown in figure 12. These
pieces  are  supplied  with  the  appliance  on
purchase.

WARNING:
THE BURNER FLAME MUST BE ADJUSTED BY
THE INSTALLER.
FAULTY  INSTALLATION  WILL  NOT  BE
COVERED UNDER WARRANTY.
THE  APPLIANCE  IS  FACTORY  SET  FOR
NATURAL  GAS.  THE  TEST  POINT  PRESSURE
SHOULD BE ADJUSTED TO 1.00kPa WITH THE
WOK BURNER OPERATING AT MAXIMUM.

INSTALLATION

FIG. 11

FIG. 12

IMPORTANT: 
a  perfect  installation,  adjustment  or
transformation  of  the  cooktop  to  use  other
gases  requires  a  QUALIFIED  INSTALLER:  a
failure  to  follow  this  rule  will  void  the
warranty.

Summary of Contents for VGH60

Page 1: ...Instructions and installation user manual MODELS VGH64 VGH64C VGH60 VGH60C VGH64CF PLEASE READ THIS MANUAL BEFORE INSTALLING THE COOKTOP COD 01099HT 17 10 2012...

Page 2: ...set and program your LED clock and importantly taking care of your appliance when cleaning please call us because we are here to help you It is important that you read through the following use and ca...

Page 3: ...4 MJ 17 Trivet for ultra rapid burner 18 Burner 16 control knob Attention this appliance has been manufactured for domestic use only Do not modify this appliance DESCRIPTION OF THE COOKTOP MODELS VGH6...

Page 4: ...Pan in cm Natural U LPG Ultra rapid or Wok 14 5 MJ 11 4 MJ 22 24 Rapid 12 0 MJ 10 4 MJ 20 22 Semi rapid 7 1 MJ 6 2 MJ 16 18 Auxiliary 4 1 MJ 3 5 MJ 10 14 WARNINGS Burners with flame failure device VG...

Page 5: ...children who might play on an abandoned appliance Do not touch the appliance with wet or damp hands or feet Do not use the appliance barefoot The manufacturer will not be liable for any damage result...

Page 6: ...ge of the cooktop Do not force the taps if they are difficult to open or close Contact the technical assistance service for repairs Don t use steam jets for cleaning the cooktop CARE MAINTENANCE To op...

Page 7: ...ements given for the hole into which the appliance will be recessed see fig 8 Any adjoining wall surface situated within 200 mm from the edge of any hob burner must be a suitable non combustible mater...

Page 8: ...Natural Gas installations require the connection of a gas regulator at the appliance Assemble the regulator noting the gas flow direction and transition pieces supplied with the appliance in accordan...

Page 9: ...y main by a socket Fit a standard plug suited to the load indicated on the data label to the cable Fit the wires following figure n 13 taking care of respecting the following correspondences Letter L...

Page 10: ...appliance fails to operate correctly after all checks have been carried out contact a qualified service agent in your area 7 TAPS Our taps are suitable for all gas they are male conical type Reduced...

Page 11: ...the Only for use with U LPG label adhered to the bottom panel near the gas connection 9 NATURAL GAS TO UNIVERSAL LPG CONVERSION PROCEDURE Appliance models Gas stainless steel cooktop models VGH60C VG...

Page 12: ...gulation on the appliance instead of the already existing one This label is supplied in the packet containing the spare injectors The envelope with the injectors and the labels can be included in the...

Page 13: ...is replaced to ensure a perfect tightness Greasing the taps see fig 17 18 If a tap becomes stiff to operate it must be immediately greased in compliance with the following instructions Remove the tap...

Page 14: ...PLY CABLE TYPES AND SECTIONS ATTENTION If the power supply cable is replaced the installer should leave the ground wire longer than the phase conductors fig 19 and comply with the recommendations give...

Page 15: ...or our nearest After Sales Service Center whenever repairs or adjustments are required specifying the type of fault and the model of the appliance in your possession Please also note that genuine spa...

Page 16: ...16...

Reviews: