Venini VGH60 Instructions And Installation  User Manual Download Page 12

12

CONVERSIONS

10) REPLACING THE INJECTORS

The burners can be adapted to different types of gas
by  installing  injectors  suited  to  the  type  of  gas
required.  To  do  this,  first  remove  the  burner  tops
using  a  wrench  “B”.  Now  unscrew  injector  “A”  (see
fig. 15) and fit a injector corresponding to the type of
gas required.
It is advisable to tighten the injector in place.

After  the  injectors  have  been  replaced,  the
burners  must  be  regulated  as  explained  in
paragraphs 7. The technician must reset any seals
on  the  regulating  or  pre-regulating  devices  and

affix  the  label  corresponding  to  the  new  gas
regulation on the appliance instead of the already
existing  one.  This  label  is  supplied  in  the  packet
containing the spare injectors.
The envelope with the injectors and the labels can
be  included  in  the  kit,  or  at  disposal  to  the
Customer Care Department.

For the sake of convenience, the nominal rate chart
also lists the heat inputs of the burners, the diameter
of  the  injectors  and  the  working  pressures  of  the
various types of gas.

BURNER ARRANGEMENT ON THE COOKTOP  

1

RAPID

U-LPG

2.75

91

10.4

NATURAL

1.00

155

12.0

2

SEMI-RAPID

U-LPG

2.75

70

6.2

NATURAL

1.00

120

7.1

3

AUXILIARY

U-LPG

2.75

53

3.5

NATURAL

1.00

90

4.1

16

ULTRA RAPID

U-LPG

2.75

94

11.4

NATURAL

1.00

176

14.5

TABLE 1

BURNERS

DESCRIPTION

GAS

NORMAL

PRESSURE

INJECTOR

DIAMETER

NOMINAL 

HEAT INPUT (MJ/h)

(kPa)

(1/100 mm)

MAX.

FIG. 15

Summary of Contents for VGH60

Page 1: ...Instructions and installation user manual MODELS VGH64 VGH64C VGH60 VGH60C VGH64CF PLEASE READ THIS MANUAL BEFORE INSTALLING THE COOKTOP COD 01099HT 17 10 2012...

Page 2: ...set and program your LED clock and importantly taking care of your appliance when cleaning please call us because we are here to help you It is important that you read through the following use and ca...

Page 3: ...4 MJ 17 Trivet for ultra rapid burner 18 Burner 16 control knob Attention this appliance has been manufactured for domestic use only Do not modify this appliance DESCRIPTION OF THE COOKTOP MODELS VGH6...

Page 4: ...Pan in cm Natural U LPG Ultra rapid or Wok 14 5 MJ 11 4 MJ 22 24 Rapid 12 0 MJ 10 4 MJ 20 22 Semi rapid 7 1 MJ 6 2 MJ 16 18 Auxiliary 4 1 MJ 3 5 MJ 10 14 WARNINGS Burners with flame failure device VG...

Page 5: ...children who might play on an abandoned appliance Do not touch the appliance with wet or damp hands or feet Do not use the appliance barefoot The manufacturer will not be liable for any damage result...

Page 6: ...ge of the cooktop Do not force the taps if they are difficult to open or close Contact the technical assistance service for repairs Don t use steam jets for cleaning the cooktop CARE MAINTENANCE To op...

Page 7: ...ements given for the hole into which the appliance will be recessed see fig 8 Any adjoining wall surface situated within 200 mm from the edge of any hob burner must be a suitable non combustible mater...

Page 8: ...Natural Gas installations require the connection of a gas regulator at the appliance Assemble the regulator noting the gas flow direction and transition pieces supplied with the appliance in accordan...

Page 9: ...y main by a socket Fit a standard plug suited to the load indicated on the data label to the cable Fit the wires following figure n 13 taking care of respecting the following correspondences Letter L...

Page 10: ...appliance fails to operate correctly after all checks have been carried out contact a qualified service agent in your area 7 TAPS Our taps are suitable for all gas they are male conical type Reduced...

Page 11: ...the Only for use with U LPG label adhered to the bottom panel near the gas connection 9 NATURAL GAS TO UNIVERSAL LPG CONVERSION PROCEDURE Appliance models Gas stainless steel cooktop models VGH60C VG...

Page 12: ...gulation on the appliance instead of the already existing one This label is supplied in the packet containing the spare injectors The envelope with the injectors and the labels can be included in the...

Page 13: ...is replaced to ensure a perfect tightness Greasing the taps see fig 17 18 If a tap becomes stiff to operate it must be immediately greased in compliance with the following instructions Remove the tap...

Page 14: ...PLY CABLE TYPES AND SECTIONS ATTENTION If the power supply cable is replaced the installer should leave the ground wire longer than the phase conductors fig 19 and comply with the recommendations give...

Page 15: ...or our nearest After Sales Service Center whenever repairs or adjustments are required specifying the type of fault and the model of the appliance in your possession Please also note that genuine spa...

Page 16: ...16...

Reviews: