USE

Notes:
Use of a gas cooking appliance produces heat and moisture in the room in which it is installed. The
room  must  therefore  be  well  ventilated  by  keeping  the  natural  air  vents  clear  (fig.  3)  and  by
activating the mechanical aeration device (suction hood or electric fan fig. 4 and fig. 5).
Intensive and lengthy use of the appliance may require additional ventilation. This can be achieved
by opening a window or by increasing the power of the mechanical exhausting system if installed.
Star Trivet: use star trivet whenever using a small pot.
Do not attempt to change the technical characteristics of the product because it can be dangerous.
- If you should not use this appliance any more (or replace an old model), before disposing of it,

make it inoperative in conformity with current law on the protection of health and the prevention of
environmental  pollution  by  making  its  dangerous  parts  harmless,  especially  for  children  who
might play on an abandoned appliance.

- Do not touch the appliance with wet or damp hands or feet.
- Do not use the appliance barefoot.
-  The  manufacturer  will  not  be  liable  for  any  damage  resulting  from  improper,  incorrect  or

unreasonable use.

- During, and immediately after operation, some parts of the cooktop are very hot: avoid touching

them.

- After using the cooktop, make sure that the knob is in the closed position and close the main tap of

the gas supply or gas cylinder.

-  If the gas taps are not operating correctly, call the Customer Care Department.
Abnormal Operation:

Any of the following are considered to be abnormal operation and may require servicing:
- Yellow tipping of the hob burner flame.
- Sooting up of cooking utensils.
- Burners not igniting properly.
- Burners failing to remain alight.
- Burners extinguished by cupboard doors.
- Gas valves which are difficult to turn.

In case the appliance fails to operate correctly, contact the 

customer care department.

.

FIG. 3

FIG. 4

FIG. 5

(*) Air inlet – minimun section 100 cm

2

Warning: 
during  operation  the  work  surfaces  of  the
cooking area become very hot: keep children
away!

Summary of Contents for VGH60

Page 1: ...Instructions and installation user manual MODELS VGH64 VGH64C VGH60 VGH60C VGH64CF PLEASE READ THIS MANUAL BEFORE INSTALLING THE COOKTOP COD 01099HT 17 10 2012...

Page 2: ...set and program your LED clock and importantly taking care of your appliance when cleaning please call us because we are here to help you It is important that you read through the following use and ca...

Page 3: ...4 MJ 17 Trivet for ultra rapid burner 18 Burner 16 control knob Attention this appliance has been manufactured for domestic use only Do not modify this appliance DESCRIPTION OF THE COOKTOP MODELS VGH6...

Page 4: ...Pan in cm Natural U LPG Ultra rapid or Wok 14 5 MJ 11 4 MJ 22 24 Rapid 12 0 MJ 10 4 MJ 20 22 Semi rapid 7 1 MJ 6 2 MJ 16 18 Auxiliary 4 1 MJ 3 5 MJ 10 14 WARNINGS Burners with flame failure device VG...

Page 5: ...children who might play on an abandoned appliance Do not touch the appliance with wet or damp hands or feet Do not use the appliance barefoot The manufacturer will not be liable for any damage result...

Page 6: ...ge of the cooktop Do not force the taps if they are difficult to open or close Contact the technical assistance service for repairs Don t use steam jets for cleaning the cooktop CARE MAINTENANCE To op...

Page 7: ...ements given for the hole into which the appliance will be recessed see fig 8 Any adjoining wall surface situated within 200 mm from the edge of any hob burner must be a suitable non combustible mater...

Page 8: ...Natural Gas installations require the connection of a gas regulator at the appliance Assemble the regulator noting the gas flow direction and transition pieces supplied with the appliance in accordan...

Page 9: ...y main by a socket Fit a standard plug suited to the load indicated on the data label to the cable Fit the wires following figure n 13 taking care of respecting the following correspondences Letter L...

Page 10: ...appliance fails to operate correctly after all checks have been carried out contact a qualified service agent in your area 7 TAPS Our taps are suitable for all gas they are male conical type Reduced...

Page 11: ...the Only for use with U LPG label adhered to the bottom panel near the gas connection 9 NATURAL GAS TO UNIVERSAL LPG CONVERSION PROCEDURE Appliance models Gas stainless steel cooktop models VGH60C VG...

Page 12: ...gulation on the appliance instead of the already existing one This label is supplied in the packet containing the spare injectors The envelope with the injectors and the labels can be included in the...

Page 13: ...is replaced to ensure a perfect tightness Greasing the taps see fig 17 18 If a tap becomes stiff to operate it must be immediately greased in compliance with the following instructions Remove the tap...

Page 14: ...PLY CABLE TYPES AND SECTIONS ATTENTION If the power supply cable is replaced the installer should leave the ground wire longer than the phase conductors fig 19 and comply with the recommendations give...

Page 15: ...or our nearest After Sales Service Center whenever repairs or adjustments are required specifying the type of fault and the model of the appliance in your possession Please also note that genuine spa...

Page 16: ...16...

Reviews: