Electrical supply
All three models require connection to a
10 Amp
wall socket
.
Instructions
1. The model number and the type of appliance, gas pressure and gas type
a
re found on
the inside of the oven door, centre bottom.
2. The appliance requires connection to a 240 V,50 Hz electric supply. The power point
must be installed by an authorized person.
3. Before commencing any work, make sure that the power point switches
a
re turned off
and the three
p
in plug is removed
.
4. If the appliance cannot be adjusted to perform correctly contact your local gas utility.
5. Instruct the user in the operation of the appliance before leaving.
Vertical clearances:
The cooker sh
ould
be installed so that a vertical clearance of at least 600 mm is maintained
between its burners and any combustible material, and where this is not practic
al
, the
underside of an
y
combustible material less than 600 mm above the burner sh
ould
be
protected by noncombustible millboard at least 6 mm thick which is covered with sheet
metal not less than 0.4 mm thick, or sh
ould
be protected by an equivalent material,
extending at least 225 mm beyond the sides of the cooker.
Overhead clearances:
Range hoods and exhaust fans sh
ould
be installed in accordance with the manufacturer's
instructions. However, in no case sh
ould
the clearance between the top of the highest burner
of the cooking appliance and the underside of a range hood be less
than 600mm,
or an
overhead exhaust fan,
750 mm
.
Side clearances
to vertical surface:
If the distance measured from the periphery of the nearest burner to any vertical
combustible surface, is less than 200 mm, the surface sh
ould
be protected in accordance
with clause 5.12.1.1 and 5.12.1.2 of A5 5601.
Installation
Make sure the minimum clearances to combustible materials are maintained during the
installation including adequate space for the operation and servicing of the cooker. For
height limitations use the dimensions as shown in the drawing.