HELPFUL HINTS 

Abnormal Operation 
Any of the following are considered to be abnormal operation and may require servicing: 

Yellow tipping of the burner flame. 
Sooting up of cooking utensils. 
Burners not igniting properly. 
Burners failing to remain alight. 
Burners extinguished by cupboard doors. 
Gas valves, which are difficult to turn. 
In case the appliance fails to operate correctly, 

contact the authorised Service Department, 

CUCINA Appliances on 1800 444 357 
WARNING

: Servicing should be carried out only by authorised personnel.

Always use the correct diameter pan, one that is the same or slightly larger than the flame ring. 
The flame should never exceed the diameter of the pan. 
The bottom of the pan should be flat and wherever possible, keep the lid on the pan when 
cooking. 

Depending on the model the following burners are provided: 
Large (Rapid or Triple Crown) – for rapid cooking or boiling large quantities of liquid 
Wok – for rapid cooking or boiling large quantities of liquid 
Medium (Semi-rapid) – for general cooking 
Small (Auxiliary)– for slow or simmer cooking 
Fish Kettle – for specialised cooking 

All burners are variable between full and low positions 

WARNING 

Do not use commercial simmering aids as these can create excessive heat, which can damage the 
appliance. 

CLEANING THE APPLIANCE 

Alway

s

allow the appliance to cool down before cleaning to avoid a burn injury. 

Do not use caustic or abrasive agents, coarse wire wool or hard tools as these can damage the 
surface finishes. 

Normally, wiping with a soft cloth dampened with hot detergent solution is sufficient but for 
stubborn marks the following is recommended: 

Vitreous Enamel parts – use only a cleaner that is recommended for this type of material. 

Burner Assemblies – remove from the hob and soak for about 10 minutes in hot detergent 
solution. Rinse off and dry checking that the burner holes are not clogged, then reassemble in the 
correct order.

7

Summary of Contents for V3G1WC6

Page 1: ...GAS HOBS USER AND INSTALLATION INSTRUCTIONS...

Page 2: ...et and program your LED clock and importantly taking care of your appliance when cleaning please call us because we are here to help you It is important that you read through the following use and car...

Page 3: ...or future reference please record the following information which can be found on the Rating Plate and the date of purchase which can be found in the invoice Model Number Serial Number Date of Purchas...

Page 4: ...CONTENTS General Information page 4 Warning and Safety Instructions page 5 Instructions for Use pages 6 7 Instructions for Installation Pages 8 12 Technical Data Pages 12 13 3...

Page 5: ...aim Your new appliance is guaranteed against electrical or mechanical defects subject to certain exclusions noted in Conditions of Guarantee The aforegoing does not affect your statutory rights In the...

Page 6: ...or the heating area to be used never smaller Do not allow electrical fittings or cables to be in contact with hot areas of the appliance Do not use the appliance for space heating or to dry clothes Do...

Page 7: ...s been established the knob can be released 2 Manual Ignition After pressing in and turning the appropriate knob anti clockwise to the large flame symbol press the ignition button located on the contr...

Page 8: ...id or Triple Crown for rapid cooking or boiling large quantities of liquid Wok for rapid cooking or boiling large quantities of liquid Medium Semi rapid for general cooking Small Auxiliary for slow or...

Page 9: ...ustible construction above the hotplate must be at least 700mm above the top surface of the bench and no construction shall be within 450mm above the top of the burner Allow a 10mm minimum clearance b...

Page 10: ...aling agent or overlap the thickness NOTE do not use any Silicone based sealant as this can damage the worktop surface if repairs are required 4 Insert the appliance into the aperture and fix in posit...

Page 11: ...ctory set for Natural gas The test point pressure should be adjusted to 1 00kPa with the largest burner operating at maximum flame Natural Gas 1 00kPa Propane Gas 2 75kPa When converting from Natural...

Page 12: ...our stable and noiseless and does not extinguish when changing from maximum to minimum flow x Replace the control knob and check that all components have been reassembled correctly Before Leaving Chec...

Page 13: ...al marked E or the earth symbol A or coloured green and yellow The wire coloured Blue must be connected to the terminal marked N or coloured blue or Black The wire coloured Brown must be connected to...

Page 14: ...and seating with a cloth dampened with solvent x Lightly smear the cone with high temperature grease reassemble into position and rotate a few times Remove the cone again and remove any excess grease...

Page 15: ...6 3 3 6 27 V3G1WC6 6 3 3 6 12 5 28 7 VECG6003 10 8 6 3 3 6 27 VECG6006 10 8 6 3 3 6 27 VECG6004 6 3 3 6 12 5 28 7 VECG6007 6 3 3 6 12 5 28 7 VECG7001 10 8 6 3 3 6 12 5 39 5 VECG9002 10 8 6 3 3 6 12 5...

Page 16: ...15...

Reviews: