NATURAL GAS BURNER TYPES AND POWER INPUTS : MJ/h

Model

Large

Medium

Small

Wok

Fish

Total

max

max

max

max

max

max

VE0260011.2

11.9

7

4

-

-

29.9

VGC6

11.9

7

4

-

-

29.9

VGCWS6

-

7

4

12.7

-

30.7

V4GC6

11.9

7

4

-

-

29.9

V3G1WC6

-

7

4

12.7

-

30.7

VECG6003

11.9

7

4

-

-

29.9

VECG6006

11.9

7

4

-

-

29.9

VECG6004

-

7

4

12.7

-

30.7

VECG6007

-

7

4

12.7

-

30.7

VECG7001

11.9

7

4

12.7

-

41.8

VECG9002

11.9

7

4

12.7

-

41.8

PROPANE GAS BURNER TYPES AND POWER INPUTS : MJ/h

Model

Large

Medium

Small

Wok

Fish

Total

max

max

max

max

max

max

VE0260011.2

10.8

6.3

3.6

-

-

27

VGC6

10.8

6.3

3.6

-

-

27

VGCWS6

-

6.3

3.6

12.5

-

28.7

V4GC6

10.8

6.3

3.6

-

-

27

V3G1WC6

-

6.3

3.6

12.5

-

28.7

VECG6003

10.8

6.3

3.6

-

-

27

VECG6006

10.8

6.3

3.6

-

-

27

VECG6004

-

6.3

3.6

12.5

-

28.7

VECG6007

-

6.3

3.6

12.5

-

28.7

VECG7001

10.8

6.3

3.6

12.5

-

39.5

VECG9002

10.8

6.3

3.6

12.5

-

39.5

JET SIZING CONVERSION TABLE: NATURAL GAS / LPG

Model

Large

Medium

Small

Wok

Fish

NG/LPG

NG/LPG

NG/LPG

NG/LPG

NG/LPG

VE0260011.2

1.55 / 0.90

1.18 / 0.69

0.90 / 0.53

-

-

VGC6

1.55 / 0.90

1.18 / 0.69

0.90 / 0.53

-

-

VGCWS6

-

1.18 / 0.69

0.90 / 0.53

1.60 / 0.97

-

V4GC6

1.55 / 0.90

1.18 / 0.69

0.90 / 0.53

-

-

V3G1WC6

-

1.18 / 0.69

0.90 / 0.53

1.60 / 0.97

-

VECG6003

1.55 / 0.90

1.18 / 0.69

0.90 / 0.53

-

-

VECG6006

1.55 / 0.90

1.18 / 0.69

0.90 / 0.53

-

-

VECG6004

-

1.18 / 0.69

0.90 / 0.53

1.60 / 0.97

-

VECG6007

-

1.18 / 0.69

0.90 / 0.53

1.60 / 0.97

-

VECG7001

1.55 / 0.90

1.18 / 0.69

0.90 / 0.53

1.60 / 0.97

-

VECG9002

1.55 / 0.90

1.18 / 0.69

0.90 / 0.53

1.60 / 0.97

-

14

Summary of Contents for V3G1WC6

Page 1: ...GAS HOBS USER AND INSTALLATION INSTRUCTIONS...

Page 2: ...et and program your LED clock and importantly taking care of your appliance when cleaning please call us because we are here to help you It is important that you read through the following use and car...

Page 3: ...or future reference please record the following information which can be found on the Rating Plate and the date of purchase which can be found in the invoice Model Number Serial Number Date of Purchas...

Page 4: ...CONTENTS General Information page 4 Warning and Safety Instructions page 5 Instructions for Use pages 6 7 Instructions for Installation Pages 8 12 Technical Data Pages 12 13 3...

Page 5: ...aim Your new appliance is guaranteed against electrical or mechanical defects subject to certain exclusions noted in Conditions of Guarantee The aforegoing does not affect your statutory rights In the...

Page 6: ...or the heating area to be used never smaller Do not allow electrical fittings or cables to be in contact with hot areas of the appliance Do not use the appliance for space heating or to dry clothes Do...

Page 7: ...s been established the knob can be released 2 Manual Ignition After pressing in and turning the appropriate knob anti clockwise to the large flame symbol press the ignition button located on the contr...

Page 8: ...id or Triple Crown for rapid cooking or boiling large quantities of liquid Wok for rapid cooking or boiling large quantities of liquid Medium Semi rapid for general cooking Small Auxiliary for slow or...

Page 9: ...ustible construction above the hotplate must be at least 700mm above the top surface of the bench and no construction shall be within 450mm above the top of the burner Allow a 10mm minimum clearance b...

Page 10: ...aling agent or overlap the thickness NOTE do not use any Silicone based sealant as this can damage the worktop surface if repairs are required 4 Insert the appliance into the aperture and fix in posit...

Page 11: ...ctory set for Natural gas The test point pressure should be adjusted to 1 00kPa with the largest burner operating at maximum flame Natural Gas 1 00kPa Propane Gas 2 75kPa When converting from Natural...

Page 12: ...our stable and noiseless and does not extinguish when changing from maximum to minimum flow x Replace the control knob and check that all components have been reassembled correctly Before Leaving Chec...

Page 13: ...al marked E or the earth symbol A or coloured green and yellow The wire coloured Blue must be connected to the terminal marked N or coloured blue or Black The wire coloured Brown must be connected to...

Page 14: ...and seating with a cloth dampened with solvent x Lightly smear the cone with high temperature grease reassemble into position and rotate a few times Remove the cone again and remove any excess grease...

Page 15: ...6 3 3 6 27 V3G1WC6 6 3 3 6 12 5 28 7 VECG6003 10 8 6 3 3 6 27 VECG6006 10 8 6 3 3 6 27 VECG6004 6 3 3 6 12 5 28 7 VECG6007 6 3 3 6 12 5 28 7 VECG7001 10 8 6 3 3 6 12 5 39 5 VECG9002 10 8 6 3 3 6 12 5...

Page 16: ...15...