Instructions for programming SVE01 Board
functions
27
© SandenVendo Europe SpA
12 MDB Bill Acc.Low Change 2(*)
This parameter allows you to set the bills to be accepted under low change
condition (refer to "MDB Coin Accepted1" for explanation)
13 MDB Coin Accepted (*)
This parameter allows you to set the coin to be accepted under normal condition of
sales
These parameters are used to accept or inhibit 16 different types of coins
Coins accepted 1 = from coin 1 to 8
Coins accepted 2 = from coin 9 to 16
Coin 1 corresponds to the lowest accepted value, and coin 16 is the highest.
Each coin has a corresponding binary value:
Example: To accept coins 1 – 2 – 3 – 4 –13 – 15 sum up the respective values:
Accepted coins 1 = 1 + 2 + 4 + 8 = 15
Accepted coins 2 = 16 + 64 = 80
14 MDB Coin Accepted 2(*)
This parameter allows you to set the coin to be accepted under normal condition of
sales (refer to "MDB Coin Accepted1" for explanation)
15 MDB Coin Acc.Low Change 1(*)
This parameter allows you to set the coin to be accepted under low change
condition (refer to "MDB Coin Accepted1" for explanation)
16 MDB Coin Acc.Low Change 2(*)
This parameter allows you to set the coin to be accepted under low change
condition (refer to "MDB Coin Accepted1" for explanation)
17 MDB Force vend
This parameter is used to prevent the use of the vending machine coins as change,
in practice when this parameter is enabled, you can get the rest only in the following
cases:
By placing the money and making a selection (both with a full column and with an
empty column).
Inserting a number of coins that can be returned to the coin mechanism (coins that
go in the change tubes) that do not reach the maximum price.
Note
: If you use the key with the possibility of charging, you can activate the forced
sale
coin 1 = 1
coin 9 = 1
coin 2 = 2
coin 10 = 2
coin 3 = 4
coin 11 = 4
coin 4 = 8
coin 12 = 8
coin 5 = 16
coin 13 = 16
coin 6 = 32
coin 14 = 32
coin 7 = 64
coin 15 = 64
coin 8 = 128
coin 16 = 128