Installation

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1.  Put the in wall switch into a wall box and connect the AC power wire L,N to 

DS-100 connector L, N. 

2.  Connect the wall switch to the DS-100 as Fig1 . 
3.  To manually turn ON  the  Switch, press and release  the On/Off button. The 

LED  will  light  ON  for  1  second,  and  the  load  plugged  into  the  Switch  will 
also turn ON. 

4.  To  manually  turn  OFF  the  Switch,  simply  press  and  release  the  On/Off 

button.  The  LED  will  light  ON  for  1  second  and  the  load  plugged  into  the 
Switch will turn OFF. 

 
 

Programming 
 

1.    Basic Command Class / Binary Switch Command Class 

The  Switch  will  respond  to  BASIC  and  BINARY  SWITCH  commands  that 
are part of the Z-Wave system. 

 

1-1 BASIC_GET / BINARY_SWITCH_GET 
Since  the  switch  have  two  relay,  the  Switch  will  report  its  On/Off  state  to 
the Controller by setting Configuration parameter 3. 

 
Configuration parameter 3=1      Report ON when relay 1 ON 
 

 

 

 

 

 

Report OFF when relay 1 OFF   

 

 

Configuration parameter 3=2      Report ON when relay 2 ON   

 

 

 

 

 

 

          Report OFF when relay 2 OFF 

 
 

Configuration parameter 3=3 (default)   

Report ON when either relay 1 ON or relay 2 ON 

 

 

 

 

 

        Report OFF when both relay 1 and relay 2 OFF 

         

Basic Get Command: [Command Class Basic, Basic Get] 

Basic Report Command: 
Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)] 
Report ON:[Command Class Basic, Basic Report, Value = 255(0xFF)]

 

 
 

Binary  Switch  Get  Command:[Command  Class  Switch  Binary,  Switch 
Binary Get]
 
Binary Switch Report Command: 
Report OFF:[Command Class Switch Binary, Switch Binary Report, 
Value =0(0x00)]
 
Report ON:[Command Class Switch Binary, Switch Binary Report, Value 
= 255(0xFF)]

 

 

1-2 BASIC_SET / SWITCH_BINARY_SET 

Since the switch has two relay, the load attached to the Switch will turn on 
or off upon receipt of the following commands from a Z-Wave Controller by 
setting Configuration parameter 3. 
 
Configuration parameter 3=1    switch ON and OFF of relay 1   
 

 

Configuration parameter 3=2    switch ON and OFF of relay 2   

 

 

 

 

 

 

   

 

Configuration parameter 3=3(default)     

switch ON and OFF both relay 1 and relay 2 

 

 

 

 

 

 

   

[Command  Class  Basic,  Basic  Set,  Value  =  1~99,  255(0xFF)]:  the  load 
attached to the Switch turns on. 

Summary of Contents for DS-100

Page 1: ...etecting overload state the Module will be disabled and its On Off button will be lockout of which LED will flash quickly However disconnect and re connect the Module will reset its overload condition...

Page 2: ...Controller means inclusion Removing a node ID allocated by Z Wave Controller means exclusion Failed or success in including excluding the node ID can be viewed from the Z Wave Controller Sometimes pe...

Page 3: ...port ON when relay 2 ON Report OFF when relay 2 OFF Configuration parameter 3 3 default Report ON when either relay 1 ON or relay 2 ON Report OFF when both relay 1 and relay 2 OFF Basic Get Command Co...

Page 4: ...3 Binary Switch Report ON Command Class Switch Binary Switch Binary Report Value 255 0xFF OFF Command Class Switch Binary Switch Binary Report Value 0 0x00 2 1 2 Instant Power Consumption vary over 5...

Page 5: ...it Meter Reset Command Command Class Meter Meter Reset 2 2 4 AC load Voltage V When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Me...

Page 6: ...int set to 3 DS 100 will reply ON 0xFF when either Relay 1 or Relay2 is ON report OFF 0x00 when both Relay 1 and Relay2 are OFF Below is an example show a source endpoint 5 send a Get command to DS 10...

Page 7: ...value will be 0 Bit Address Destination End Point 0x01 Bit Address 0 Destination End Point range1 3 Command Class 0x25 Command_Class_Switch_Binary 0x25 Command 0x01 Switch_Binary_Set 0x01 Parameter 1...

Page 8: ...l this value will be 0 Bit Address Destination End Point 0x01 Bit Address 0 Destination End Point range1 3 Command Class 0x32 Command_Class_Meter_V3 0x32 Command 0x05 Meter_Reset 0x05 2 3 5 METER_GET...

Page 9: ...rce End Point 0x05 this is the endpoint of command inquirer here we assume endpoint is 5 if the inquirer doesn t support multi Channel this value will be 0 Bit Address Destination End Point 0x03 Bit A...

Page 10: ...Scale V 0x04 DS 100 AC load Voltage report example COMMAND_CLASS_MULTI_CHANNEL MULTI_CHANNEL_CMD_ENCAP Source End Point 0x03 Meter report Endpoint3 Bit Address Destination End Point 0x05 Bit Address 0...

Page 11: ...02 Parameter 1 0xA1 Scale Bit2 1 Rate Type 0x01 Meter Type 0x01 Parameter 2 0x4A Precision 2 Scale Bit1Bit0 0x01 Size 2 Parameter 3 0x00 Current 0x002B 0 43A Parameter 4 0x2B 2 3 5 5 Get power factor...

Page 12: ...0 7 Restore switch state mode 1 0 2 1 0 Switch off 1 Last switch state 2 Switch on 8 Auto off timer 2 0 0x7FFF 1s 0 0 Disable auto off function 1 0x7FFF 1s 32767s 9 RF off command mode 1 0 3 0 0 Switc...

Page 13: ...same position correspond to same state of relay1 and relay2 if the DS 100 relay change the state because of receiving Z Wave RF command it may need two times of change switch on to off or switch off...

Page 14: ...Endpoint3 is dynamic 4 Protection Command Classes DS 100 supports Protection Command Class version 2 it can protect the switch against unintentionally control by e g a child And it can also protect t...

Page 15: ...environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collect...

Page 16: ...armful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by...

Reviews: