Source End Point = 0x03 

(Meter report = Endpoint3) 

(Bit Destination End Point = 

0x05) 

 

(Bit Address =0

Destination End Point = 

command inquirer’s Endpoint value) 

Command Class = 0x32 

(Command_Class_Meter_V3 = 0x32) 

Command =0x02 

(Meter_Report = 0x02) 

Parameter 1 = 0xA1 

(Scale Bit2 = 1, Rate Type = 0x01,   

Meter Type=0x01) 

Parameter 2 = 0x51 

(Precision = 2, Scale Bit1Bit0 = 0x10, Size 

= 1) 

Parameter 3 = 0x63 

Power Factor = 0x63 = 0.99

 

 
2.  Z-Wave’s Configuration 
 

Configuration 
Parameter 

Function 

Size 
(Byte) 

Value 

Unit 

Default 

Description 

Watt Meter 
Report   
Period 

0x01- 
0x7FFF 

5s 

720 

720*5s=3600s=1 
hour 

KWH 
Meter 
Report   
Period 

0x01- 
0x7FFF 

10min  6 

6*10min= 1 hour 

Selected 
Relay 
 

1-3 

 

1

Relay1   

2

Relay2 

3

Relay1 & 

Relay2 

Edge or 
Pulse 
mode or 

1-3 

 

1

Edge mode 

 
2

Pulse mode 

Edge-Toggl
e mode 

 
3

Edge-Toggle           

mode 

Threshold 
of current 
for Load 
Caution 

10-750 

0.01A 

750 
 

750*0.01A = 7.5A 

Threshold 
of KWH for 
Load 
Caution 

1-10000 

1KWh 

10000 

 

Restore 
switch 
state mode 

0-2 

 

0 : Switch off 
1 : Last switch 

state 

2 : Switch on 

Auto off 
timer   

0-0x7FFF   

1s 

0 : Disable auto 

off function 

1-0x7FFF : 1s ~ 

32767s 

RF off 
command 
mode 

0-3 

 

0 : Switch off 
1 : Ignore 
2 : Switch toggle 
3 : Switch on 

10 

Existence 
of 
Endpoint3 

1-2 

 

1 : Endpoint3 exist 
2 : No Endpoint3 
 

 

 

3-1 Watt Meter Report Period: 

    If  the  setting  is  configured  for  1hour  (set  value  =720),  the  DS-100  will  report 

its instant power consumption every 1 hour to the node of correspond Group.   
The  maximum  interval  to  report  its  instant  power  consumption  is  45  hours 
(5s*32767/3600=45hr). 

 

3-2 KWH Meter Report Period: 

      If the setting is configured for 1hour (set value =6), the DS-100 will report its 

Accumulated Power Consumption (KW/h) every 1 hour to the node of 
correspond Group. The maximum interval to report its Accumulated Power 
Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days). 

 
3-3 Selected Relay 
 

If Controller not using  Multi_Channel command class to access the relay of 
DS-100,  you  may  configure  the  select  value  to  react  the  Basic  Command 
Class

Binary Switch Command Class or Meter Command Class V3 

Summary of Contents for DS-100

Page 1: ...etecting overload state the Module will be disabled and its On Off button will be lockout of which LED will flash quickly However disconnect and re connect the Module will reset its overload condition...

Page 2: ...Controller means inclusion Removing a node ID allocated by Z Wave Controller means exclusion Failed or success in including excluding the node ID can be viewed from the Z Wave Controller Sometimes pe...

Page 3: ...port ON when relay 2 ON Report OFF when relay 2 OFF Configuration parameter 3 3 default Report ON when either relay 1 ON or relay 2 ON Report OFF when both relay 1 and relay 2 OFF Basic Get Command Co...

Page 4: ...3 Binary Switch Report ON Command Class Switch Binary Switch Binary Report Value 255 0xFF OFF Command Class Switch Binary Switch Binary Report Value 0 0x00 2 1 2 Instant Power Consumption vary over 5...

Page 5: ...it Meter Reset Command Command Class Meter Meter Reset 2 2 4 AC load Voltage V When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Me...

Page 6: ...int set to 3 DS 100 will reply ON 0xFF when either Relay 1 or Relay2 is ON report OFF 0x00 when both Relay 1 and Relay2 are OFF Below is an example show a source endpoint 5 send a Get command to DS 10...

Page 7: ...value will be 0 Bit Address Destination End Point 0x01 Bit Address 0 Destination End Point range1 3 Command Class 0x25 Command_Class_Switch_Binary 0x25 Command 0x01 Switch_Binary_Set 0x01 Parameter 1...

Page 8: ...l this value will be 0 Bit Address Destination End Point 0x01 Bit Address 0 Destination End Point range1 3 Command Class 0x32 Command_Class_Meter_V3 0x32 Command 0x05 Meter_Reset 0x05 2 3 5 METER_GET...

Page 9: ...rce End Point 0x05 this is the endpoint of command inquirer here we assume endpoint is 5 if the inquirer doesn t support multi Channel this value will be 0 Bit Address Destination End Point 0x03 Bit A...

Page 10: ...Scale V 0x04 DS 100 AC load Voltage report example COMMAND_CLASS_MULTI_CHANNEL MULTI_CHANNEL_CMD_ENCAP Source End Point 0x03 Meter report Endpoint3 Bit Address Destination End Point 0x05 Bit Address 0...

Page 11: ...02 Parameter 1 0xA1 Scale Bit2 1 Rate Type 0x01 Meter Type 0x01 Parameter 2 0x4A Precision 2 Scale Bit1Bit0 0x01 Size 2 Parameter 3 0x00 Current 0x002B 0 43A Parameter 4 0x2B 2 3 5 5 Get power factor...

Page 12: ...0 7 Restore switch state mode 1 0 2 1 0 Switch off 1 Last switch state 2 Switch on 8 Auto off timer 2 0 0x7FFF 1s 0 0 Disable auto off function 1 0x7FFF 1s 32767s 9 RF off command mode 1 0 3 0 0 Switc...

Page 13: ...same position correspond to same state of relay1 and relay2 if the DS 100 relay change the state because of receiving Z Wave RF command it may need two times of change switch on to off or switch off...

Page 14: ...Endpoint3 is dynamic 4 Protection Command Classes DS 100 supports Protection Command Class version 2 it can protect the switch against unintentionally control by e g a child And it can also protect t...

Page 15: ...environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collect...

Page 16: ...armful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by...

Reviews: