TUO Wi-Fi RF Chronothermostat User Manual

Wi-Fi connection configuration

This sub-menu consists of 3 different screens and described below.
To switch from one screen to another, use the keys 

 and 

.

  • the device PIN. It is a 4-digit number necessary 
 

to associate the device with your Vemer account.

 

This screen also shows:

 

- the status of the Wi-Fi connection:

  

  on fixed: device connected to the home network

  

  flashing: search for Wi-Fi network in progress

 

- the association between the device and Vemer account:

  

  on fixed: associated with a Vemer account

  

  flashing: not associated with any Vemer account

 

 

 Note: during the first 20 seconds or so of this screen viewing

 

  the icon   is always flashing.

  • the MAC address of the device.
 

It is a sequence of characters that identifies

 

uniquely a device inside of a network of devices

 

(reading must be done from left to right.

 

 In the example: C28d7b)

  • the intensity of the signal between the device and the access point (

)/'

). 

 For 

values:

 

- higher than -60dB: excellent signal quality

 

- between -60dB e -90dB: good signal quality

 

- lower than -90dB: poor signal quality

 

   that could compromise communication

 

   between device and access point. In this case, 

 

   bring the device closer to the access point.

Summary of Contents for Tuo Wi-Fi RF

Page 1: ...Digital Chronothermostat TUO Wi Fi RF User Manual...

Page 2: ...ype Pagina 61 parameters for the regulation type Pagina 61 antifreeze temperature Pagina 62 adjustment of the measured temperature Pagina 62 Wi Fi connection con guration Pagina 63 minimum maximum set...

Page 3: ...he appropriate app on your smartphone or tablet available free for iOS and Android devices The device also displays the relative humidity value thanks to the built in probe The colour of the display b...

Page 4: ...ity to the connection terminals without appropriate tools must be guaranteed 4 The device must be installed and activated in compliance with current electric systems standards 5 Before accessing the c...

Page 5: ...with settings on the Vemer Cloud in progress Connection to the active Wi Fi network Measured relative humidity Con guration menu RF radiofrequency connection con guration with actuator ADV advanced pa...

Page 6: ...othermostat User Manual CONNECTION DIAGRAM L N NC NO C L N NO C NC U L N NO C NC U Connection diagram for the control of the boiler heat pumps etc Connection diagram for the supply of circulation pump...

Page 7: ...oor in an area that respects as much as possible the average temperature conditions of the entire environment Make sure that the distance between the Access Point and the device is such as to guarante...

Page 8: ...r account 5 Add Tuo Wi Fi RF to your Vemer account On the app a Choose Add Thermostat The procedure guides the user during the con guration steps of Tuo Wi Fi RF On Tuo Wi Fi RF b Hold down the keys a...

Page 9: ...ur account From this screen it s possible to choose which device to control The devices Tuo Wi Fi RF are identi ed by a square frame the devices Mithos Color Wi Fi devices by a circular frame allows y...

Page 10: ...ch this area to change the running program Operating mode Touch this area to change the operating mode heating cooling and mode automatic manual off Main Page From the screen Programs list it s possib...

Page 11: ...ign at any time of day one of the three available tempe rature T1 T2 and T3 marked by blue green and red colours Created a program for a day it s possible to copy it to any other day of the week Copy...

Page 12: ...uch the symbol on the upper right to access the advanced con guration From this screen it s possible The name of Tuo Wi Fi RF The icon that identi es it The temperature values T1 T2 and T3 The advance...

Page 13: ...r the email of the user who will receive the alarm signals set the temperature thresholds and the time delay necessary to trigger the alarm choose the type of temperature regulation on off or proporti...

Page 14: ...he device adjusts the temperature based on the value of T2 from 00 00 to 6 00 and from 8 00 to 17 00 T3 from 6 00 to 8 00 and from 17 00 to 21 00 T1 from 21 00 to 24 00 The values of T1 T2 and T3 can...

Page 15: ...ates local operation In this way the device does not check if there are new settings on the cloud and adjusts the temperature according to the local settings Local operation allows programming using t...

Page 16: ...ows setting of one of the 3 timed operations The PROG menu allows you to change the programming of the automatic operating mode The ADV menu allows you to con gure the general operating parameters of...

Page 17: ...uires the date and time settings from the server and no settings are required However if you need to manually set the date and time values proceed as follows To exit the date and time setting press th...

Page 18: ...by the symbol the summer time change winter time is identi ed by the symbol For example in Italy the summer time starts the last LST Sunday 7 of March 03 at 2 00 o clock and the last LST Sunday 7 of O...

Page 19: ...am for one or more days of the week modify one or more existing programs by personalizing the pro le that is assigning different temperature levels for one or more hours of the day How to choose a dif...

Page 20: ...set delays of 15 30 45 minutes independent for every hour of the day How to customize the pro le of a Px program starting from midnight 00 00 press the keys and to assign to each hour of the day one...

Page 21: ...T1 5 C T2 15 C T3 18 C heating winter operation T1 off T2 23 C T3 25 C conditioning summer operation How to change the temperature values T1 T2 T3 To exit the temperature change press the key once to...

Page 22: ...imed automatic set a timing during the automatic operation to maintain this operation until the timing has elapsed At the end of the timing the device activates the off operation Off timed set a timin...

Page 23: ...sed in sequence Press the keys and to change the value of the selected parameter the key to go to the next parameter the key to exit and con rm the changes Note the device exits the menu after about 4...

Page 24: ...y this parameter only in case of real need For more information on the characteristics of the on off and proportional regulation logic see Regulation type on page 71 Parameters for the regulation type...

Page 25: ...excludes the antifreeze function in this case when the device is off no minimum temperature is guaranteed Adjustment of the measured temperature In particular installation conditions it can happen th...

Page 26: ...r account on xed associated with a Vemer account ashing not associated with any Vemer account Note during the rst 20 seconds or so of this screen viewing the icon is always ashing the MAC address of t...

Page 27: ...ut then make connections between the device and the boiler or conditioner Setting up UI to choose the radiofrequency control UH to select the relay control Factory value UI radiofrequency Note the con...

Page 28: ...L Factory value 2 C NL is the upper limit Allowed values 50 C Factory value 50 C Password for key lock Under particular installation conditions for example in public buildings hotels etc it may be nec...

Page 29: ...resumes the count from 0h Display backlighting The display backlighting can be off blue after pressing a key xed of a colour that can be chosen among 48 variants variable based on the difference betwe...

Page 30: ...tion between the device and the remote actuator used to control the heating or air conditioning system The RF menu is active only if the system command mode ADV menu OUT is set to RF RF MENU CONNECTIO...

Page 31: ...the commands to the actuator is indicated by the lighting of the RF message It is possible to repeat the procedure described above to combine multiple remote actuators to be used for simultaneous dri...

Page 32: ...lue measured by the probe in the upper right corner with a resolution of 0 1 RH Humidity regulation is not possible Keypad unlock When the key lock is active the device adjusts the temperature using t...

Page 33: ...keep the key pressed until appears SET 3s SET 3s 3 Initial screen Configuration menu Operationmode heating winter Regulationtype on off Differential on off 0 3 C Band proportional 0 5 C Period proport...

Page 34: ...hat a low differential 0 1 C 0 2 C leads as a consequence more frequent ignitions of the system but the temperature will be more uniform than a high value 0 9 C 1 C Proportional regulation only for op...

Page 35: ...he ThermoPro RF valve work by opening modulation In this way the valve opens proportionally according to the difference between the set temperature set point and the detected temperature Selecting one...

Page 36: ...mes it may be necessary to delete a device from a personal account to move it to another account for example because the device is installed in a rented home and tenants change Proceed as follows 1 On...

Page 37: ...emperature regulation on off with adjustable differential between 0 1 C and 1 C proportional with settable band and regulation period Operating mode heating winter or conditioning summer Configurable...

Page 38: ...Q Q Q 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 P4 T3 Q Q Q Q Q Q Q Q Q Q Q T2 Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q T1 Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q 0...

Page 39: ...Q Q Q Q Q 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 P4 T3 Q Q Q Q Q Q Q Q Q Q Q Q Q T2 Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q T1 Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q...

Page 40: ...V3IS01009 010 Vemer S p A I 32032 Feltre BL Via Camp Lonc 16 Tel 39 0439 80638 Fax 39 0439 80619 e mail info vemer it web site www vemer it 05 2019...

Reviews: