- 40 -
Iride Chronothermostat User Manual
TIMINGS: WHAT THEY ARE
Timings allow to maintain the current operation (automatic, manual, off) for a certain
period (times or days) and once passed the chronothermostat changes the operating
mode, as explained below.
The timed operations are the following:
Timed automatic
If in automatic status you set a timing, such off status will be maintained until the end
of the timing operation, will then switched to off mode.
Timed manual
If in manual status you set a timing, such off status will be maintained until the end of
the timing; operation will then switched to automatic mode.
Emergency regulation (winter mode only)
The device performs a regulation of emergency if an error occurs during the reading of
the probe or in case of time loss.
In case of
probe error
, if the antifreeze function is not excluded, the device activates
the load for 10 minutes every 4 hours. The display shows the writing
Err
on field
(7)
.
In case of
time loss
(because of depleted batteries or blackout of a duration higher
than the charge reserve) the device restarts from the off mode, adjusting on the basis
of the antifreeze temperature, if it hasn’t been deactivated before. Reset date/ time
to go back to the normal operation (programs modifications and settings remain
memorized).
English