- 38 -
Iride Chronothermostat User Manual
6. Once all parameters are set, to exit and to go back to the programming menu, press for
a short time the key
.
To exit and to go back to the normal operation press for a long time the key
or wait
for the time-out expiration (30 seconds about).
REGULATION TYPE
Iride has got two types of regulation:
On/off regulation
During on/off regulation the chronothermostat measures once a minute the
environment temperature and it carries out the regulation on the basis of the following
logic:
relay ON
SET-DIFF
SET
relay OFF
Temperature
increasing
relay ON
SET+DIFF
SET
relay OFF
Temperature
increasing
heating mode
cooling mode
where SET represents the setpoint and DIFF the hysteresis (useful to avoid continuous
switches on/switches off dangerous for the system in proximity to the reaching of the
setpoint.
Proportional regulation (only in heating)
In heating mode, the on/off regulation is available and also the proportional regulation
which in some systems allows a more precise regulation to obtain a constant
temperature.
This regulation requires to specify two parameters:
• the band, which represents the temperature values with whom to perform the
proportional regulation. The band is centered on the setpoint and it can have values
between 0,5°C and 5°C; outside these values the heating will be
always on (if setpoint-band > environment temperature) or always off (if se
band < measured temperature).
English
Summary of Contents for Iride
Page 1: ...Chronothermostat IRIDE User Manual...
Page 2: ......
Page 14: ...12 Iride Chronothermostat User Manual BATTERY IRIDE MOUNTING Vimar Idea series VI B English...
Page 15: ...13 Iride Chronothermostat User Manual IRIDE 230 MOUNTING Vimar Idea series VI B English...
Page 49: ......
Page 50: ......
Page 51: ......