- 33 -
Iride Chronothermostat User Manual
Automatic
operation
Manual setpoint
(Tm) setting
Manual operation
3s
OFF OPERATION
In off mode the device doesn’t perform any regulation (*) but it continues to display the
day, the time and the measured temperature.
(*) When in heating / winter mode the device maintains a minimum
temperature - Toff antifreeze temperature - to avoid the freezing of the
systems where the device is installed.
Toff can have values between 1°C and 10°C or it can be completely shut
down; in this last case the saving of minimum temperature is not guaranteed.
The set default Toff is 6°C but it’s possible to modify this value entering the
ADV menu (see “Antifreeze temperature” on page 29).
To switch the device off press the key
until the symbol
is displayed (field
(9)
).
English