English
- 8 -
CHRONOS RF Radiofrequency digital chronothermostat User Manual
3. Upon receipt of the configuration string, the remote actuator is configured and
resumes the normal operation while the Chronos RF requires date and time
insertion ( the programming keys will be active only after you have hooked the
thermostat at the base)
Note: to associate a second remote actuator, activate the configuration of
the actuator channel and, while this last is in configuration mode, remove
the thermostat from the base and re-put it (the cronothermostat starts the
configuration procedure to which follows the testing procedure).
• Indications for placement
The Chronos RF is designed for wall-mounting installation or to cover the 503 box
1
1
2
Fix the base on the wall using the screws
supplied.
Attach the chronothermostat to the base,
at first mating teeth first placed on the
upper side.
Place the chronothermostat at a height at about 1.5 m above the floor, away from
direct sunlight, away from doors, windows, heat sources, locations with excess or total
lack of aeration.
The actuator is usually placed near the boiler to pilot.
Attention: the maximum distance between Chronos RF and remote actuator is about
50 m in free field. This value is reduced if there are obstacles in the middle (for
example, reinforced concrete walls).
Summary of Contents for Chronos RF Bianco