PCN101ZP
is a panel-mount controller with a LED display, suitable for operator
panels of electrical units. The cutout slot for mounting should be a
(45+0.3)x(92+0.3) mm rectangle. To secure the controller on the panel, use the
attaching brackets and screws. The connector pinout of the controller is pictured on
the rear panel.
The connecting wires must be isolated and have minimal cross sectional area
of 0.35-0.75 mm² for G1;K1 and G2;K2 control circuits. The rule to remember for the
2
power wiring is 6А/mm . The following diagrams illustrate single-phase (
) and
two-phase (
) connections to a standard dual thyristor module:
Mechanical installation and wiring
Make sure the thyristor module is well ventilated for power rates above
500W!!!