Figure E-11 VeloView List Selected Points
In
Figure E-11 above
, 14 data points were selected with a small selection rectangle. The points appear in pink. Their attrib-
utes are listed on the right. In this example, most of their intensity values exceed 100, indicating something retro-reflective
is there (see
Calibrated Reflectivity on page 32
for details). Azimuth is in hundredths of a degree. Distances are with
respect to the sensor’s origin.
At any point you can save a subset of data frames by doing File > Save As > Select Frames.
116