Features: 

 
 

VELBUS: 

 

 

 
 
 
 
 
 

  Can be used to control an electric roll-down shutter, sunblind... 

  Switching capacity at resistive load: 16A/230VAC max. 

  Switching capacity at inductive load: 8A/230VAC max. 

  Suppressed relay contacts. 

  Manual control on the module. 

  LED indications for: 

  The UP and DOWN relay output 

  The UP and DOWN control modes (fast, very fast or blinking twice and continuously ON) 

 Power voltage 

  Data reception and forwarding through VELBUS 

  4 possible switching times (adjustable through the 

‘TIME OUT’

 toggle switch): 15s - 30s - 1min - 2 min 

  Controllable by connecting several push buttons in parallel. 

  Push button input debounce: 65ms. 

  Controllable trough VELBUS. 

  Programmable without PC. 

  Easy learning process by pressing the desired push buttons in the learning mode. 

  Push button commands: up, down, immediately up and immediately down (the up and down commands will 

be operated through a single push button as from firmware version 0804).  

  Storage space for 14 different push buttons per command group (11 per command group as from firmware 

version 0804). 

  Learned push buttons will be saved in case of power failure. 

  Reporting towards the control modules in case of LED status modification.  

  250 possible addresses (adjustable through the ‘ADDR’  rotating switches) 

  Required mains voltage: 12 ... 18VDC. 

  Consumption in standby: 30mA at 18V (15mA at 16V) 

  Consumption activated relay: 80mA at 18V (60mA at 16VDC) 

  Max. consumption (activated relay and push button input): 95mA at 18V (75mA at 16VDC) 

  Standard DIN rail housing (2 modules)  

  Dimensions (L x W x H): 90 x 36 x 58mm. 

 Weight: 110g 

2-wire communication for the VELBUS data and 2 wires for power. 
Data transfer: 16,6Kbit/s. 
Serial data protocol: CAN (Controller Area Network) 
Short-circuit proof (towards negative or positive of power) 
Bus error indication: 2 x short flash of the operation mode LED. 
Self restoring after 25 seconds in case of a bus error. 
 
Possibility to assign a name (max. 16 characters) to the UP and DOWN output which can be saved in the non-
volatile memory. 
The module can react to the push button instructions sent over the VELBUS.  
Reporting on the VELBUS in case of a modification of the blind control module. 
In case of a modification of the output, the module will send instructions to modify the status of the LEDs on 
the control modules. 
The instructions will be accepted when calling up the module type, the output names, the module status, 
reading from or writing on the non-volatile memory, the rising, the descending and the stopping of the shutter. 
The module can respond with the module type, the output names, the module status or the contents from the 
memory. 

Summary of Contents for Velbus VMB1BL

Page 1: ...Velbus manual VMB1BL edition 1 rev 2 0 1 VMB1BL Blind Control Module for VELBUS system...

Page 2: ...4 Direct control through several push buttons 4 Control through the VELBUS system 6 Combination of direct push button and VELBUS control 8 Connecting a 24V direct current motor 9 Use 10 Termination 10...

Page 3: ...possible addresses adjustable through the ADDR rotating switches Required mains voltage 12 18VDC Consumption in standby 30mA at 18V 15mA at 16V Consumption activated relay 80mA at 18V 60mA at 16VDC M...

Page 4: ...push buttons which are directly connected to the push button inputs by using the VELBUS or a combination of both Direct control through several push buttons 12V COM L DOWN UP N L AC POWER OUT TIME ADD...

Page 5: ...WER OUT TIME ADDR PB M UP DOWN L H UP DWN BUS VMB1BL ONE BUTTON CONTROL 12V SUPPLY Connection of the up and down commands and the commands through a single push button is possible by using 2 diodes 1N...

Page 6: ...OUT TIME ADDR PB M UP DOWN Combination of direct push button and VELBUS control L H UP DWN BUS VMB1BL UP PUSH BUTTONS L H 12V SUPPLY BUS TWISTED PAIR 0 5mm 2 12V COM L DOWN UP N L AC POWER OUT TIME AD...

Page 7: ...BUS TWISTED PAIR 0 5mm 2 12V COM L DOWN UP N L AC POWER OUT TIME ADDR PB M UP DOWN Connection of the up and down commands and the commands through a single push button is possible by using 2 diodes 1N...

Page 8: ...or You can connect a 24V direct current motor by using a transformer with 2 secondary windings and a bridge rectifier L H UP DWN BUS VMB1BL UP PUSH BUTTONS L H 12V SUPPLY BUS TWISTED PAIR 0 5mm 2 12V...

Page 9: ...D Reception LED Power LED Address setting Switch off setting Termination Down indication LED Manuel down operation OUT PB USE Remove the lid on the blind control module using a small screwdriver to mo...

Page 10: ...of the opposite direction Maintaining the UP or DOWN push button pressed will move the shutter until the push button is released or the switch off delay has expired Pressing the UP and DOWN push butto...

Page 11: ...have been learned for the UP or DOWN control Add a specific push button by maintaining it pressed until the output activates Releasing the push button will deactivate the output while the indication...

Page 12: ...Velbus manual VMB1BL edition 1 rev 2 0 12...