Learning Mode:
Only push buttons connected to the Velbus via a push button interface or a control panel are appropriate for the
procedure below.
Following push buttons can be learned: up, immediate up, down and immediate down. Each command can accept
up to 14 different push buttons.
As from firmware version 0804 you will also be able to learn push buttons which will raise and lower the blind. The
number of push buttons per command group has been narrowed down to 11.
Memorize he unique address of the module.
Enter the address of the module as follows:
Address Command
F1
Learning push buttons rising the shutter
E1
Learning push buttons rising the shutter immediately and completely
D1
Learning push buttons lowering the shutter
C1
Learning push buttons lowering the shutter immediately and completely
B1
Learning push buttons raising and lowering the blind (as from firmware version
0804)
The outputs will be deactivated and the UP or DOWN operation LED will blink rapidly to indicate the learning
mode. The LEDs of the learned push buttons will blink rapidly as well. You can easily detect which push buttons
have been learned for the UP or DOWN control.
Add a specific push button by maintaining it pressed until the output activates. Releasing the push button will
deactivate the output while the indication LED of the push button blinks rapidly as confirmation. You can not add
any more push buttons when the maximum number of push buttons has been reached.
A learned push button can be deleted by maintaining it pressed. Releasing it will turn off the indication LED of the
push button.
Delete all learned push buttons of a control group by maintaining pressed the manual control on the blind control
module until the output switches on. Releasing the manual control push button will deactivate the output and turn
off the indication LEDs of each corresponding push button.
Repeat the procedure above to learn other commands to the push buttons.
Exit the learning mode by resetting the address of the blind control module at the original value.
When using firmware version 0735 you will be able to delete all push buttons saved into the memory of the blind
control module at once. Set the address to one of the learning addresses. Maintain the manual control on the
blind control module pressed for 10 seconds. The relay will activate and deactivate again after 7 seconds to
confirm the push buttons have been erased. Set the address back to its original value.