5.

 

Overview 

Refer to the illustrations on page 

of this manual.

 

retractable hook tip 

IC tip 

adjustment tool 

tip protector 

ground lead with crocodile clip 

identification tags 

ground bayonet 

 

6.

 

Operating instructions 

 

Connect the BNC connector to the oscillator (not incl.). Refer to the user manual of the 
oscilloscope for the correct port and operation settings.  

 

Make sure the probe is properly calibrated. Refer to 

§6 Calibration

 below. 

 

When possible, disconnect power to the circuit under test and connect the crocodile clip 
to ground or common (usually the chassis) or use the ground bayonet 

[4] 

(only fits 

over the standard tip).  

Note: 

Always use the shortest possible ground lead! Excessive ground lead length 

introduces unwanted inductance and can alter the displayed signal, as well as reduces 
the scope's effective bandwidth (ground lead acts like a low pass filter).

 

 

Depending on the measured signal, use the standard tip, the retractable hook tip 

[1]

 or 

the IC-tip 

[5]

. When wires are close together, place the tip protector 

[6]

 over the 

standard tip to avoid short circuit. 

 

When using multiple probes on the same circuit board, clip the identification tags 

[7]

 

over the probe cable, one at the side of the BNC connector and the other near the 
probe, to easily identify the signals. 

 

When possible, switch off power to the circuit under test prior to removing the probe.  

7.

 

Calibration 

 

In order to obtain the correct division ratio with each oscilloscope, the attenuation 
network needs to be adjusted. To compensate the probe to your oscilloscope, apply a 
1kHz square wave to the probe tip, or connect to the cal socket on the oscilloscope to 
display a few cycles of the waveform (refer to the illustrations on page 

of this 

manual).

 

 

Adjust the trimmer located in the BNC connector for a flat-topped square wave.

 

8.

 

Technical specifications 

attenuation x100 
bandwidth 

DC to 60MHz 

rise time 

5.8ns 

input resistance 

100M

 (input resistance scope = 1M

input capacitance 

±6.5pF 

working voltage 

1200Vdc incl. peak AC 

compensation range 

10 to 50pF 

cable length 

1.3m 

remarks 

with insulated BNC connector 

 

Use this device with original accessories only. Velleman nv cannot be held 
responsible in the event of damage or injury resulted from (incorrect) use of this 
device. For more info concerning this product and the latest version of this user 
manual, please visit our website www.velleman.eu. The information in this 
manual is subject to change without prior notice. 

© 

COPYRIGHT NOTICE

 

This manual is copyrighted. The copyright to this manual is owned by Velleman 
nv.

 All worldwide rights reserved. No part of this manual may be copied, reproduced, 

translated or reduced to any electronic medium or otherwise without the prior written 
consent of the copyright holder.  

Summary of Contents for PROBE60HV

Page 1: ...IGH V 1200 VDC POUR OSCILLO 1200 VCC DE SONDAS AI SCOPIO 60MH RTER HOCHSPA 1200VDC ANUAL KERSHANDLE D EMPLOI L DEL USUARI UNGSANLEITU V LTAGE SCOPE VOLTAGE OSCI OSCOPE HAUT ISLADAS DE A Hz 1200VDC ANN...

Page 2: ...0 Velleman nv 2 Accessories accessoires accessoires accesorios Zubeh r Calibration IJking talonnage calibraci n Eichung Voltage derating spanningsderating derating de la tension derating de la tensi n...

Page 3: ...is device should Respect the local e cal waste disposal BE60HV Please re e If the device was high impedance osc an input impedance with instruments hav ar the BNC connecto ions be used by qualified y...

Page 4: ...easily identify the signals When possible switch off power to the circuit under test prior to removing the probe 7 Calibration In order to obtain the correct division ratio with each oscilloscope the...

Page 5: ...aatselijke milie dan de plaatselijke s deze handleiding g adigd tijdens het tra ve hoogimpedante t een ingangsimpeda gangscapaciteit van ructies stemd voor geschoo k van kinderen en o kel binnen de to...

Page 6: ...ontkoppelen 7 IJking Voor de beste meetresultaten ijkt u best het verzwakkingnetwerk Gebruik een blokgolf van 1 kHz om de meetpunt te ijken of verbind de sonde met de ijkingpin van de oscilloscoop om...

Page 7: ...autorit s l e achat Lire la pr s pareil a t endomm vendeur e d oscilloscope pass M et une capacit p entr e de 10 50 p curit t e des personnes n t e des enfants et d e dans les valeurs sp er un profess...

Page 8: ...t 7 talonnage Pour les meilleurs r sultats il est conseill d talonner le r seau d att nuation talonner la pointe l aide d une onde carr e de 1 kHz ou connecter la sonde la sortie d talonnage de l osci...

Page 9: ...ades el PROBE60HV Lea aparato ha sufrido a distribuidor ondas de osciloscop da de 1 M y una ca capacidades de ent BNC de seguridad ejos del alcance de parato ejos del alcance de entro de los valores o...

Page 10: ...i n Para obtener los mejores resultados calibre la red de atenuaci n Utilice una onda cuadrada de 1 kHz para calibrar la punta o conecte la sonda a la salida de calibraci n del osciloscopio para visua...

Page 11: ...nt Recycling Unterneh hriften nden Sie sich f r E f des PROBE60HV durch berpr fen S nden Sie das Ger t ver hochohmiger O f Ger ten mit einer er Ger ten mit einer tellschraube weise ch nur f r Fachm n...

Page 12: ...den Tastkopf vom Kreis trennen 7 Kalibrierung F r die besten Messergebnisse kalibrieren Sie am besten das Teilernetzwerk Verwenden Sie eine Rechteckwelle von 1 kHz um die Tastkopfspitze zu kalibriere...

Page 13: ...tive article can also involve handling costs Repairs occurring after warranty expiration are subject to shipping costs The above conditions are without prejudice to all commercial warranties The above...

Page 14: ...ation de l appareil contraire aux prescriptions du fabricant tout dommage cause d une utilisation commerciale professionnelle ou collective de l appareil la p riode de garantie sera r duite 6 mois lor...

Page 15: ...ehe Garantiebedingungen Allgemeine Garantiebedingungen in Bezug auf Konsumg ter f r die Europ ische Union Alle Produkte haben f r Material oder Herstellungsfehler eine Garantieperiode von 24 Monaten a...

Reviews: