6.
Connect the wiring
[1]
to the terminals according to the diagram
on page
2
. Wire colours:
x red (+)
y black (-)
z brown
Warning:
do not short-circuit any terminals.
7.
Connect the power supply.
8.
To test the PIR sensor, set the light sensitivity to OFF and the
movement sensitivity and 5” to ON. The load should switch on
immediately and – when no movement is detected – switch off
after 5s.
Note:
DO NOT change the DIP switch settings when power is
connected!
5.
Technical Specification
detection angle
100°
detection range
8 m (@ 22 °C)
rated load
30 W resistive load
input
12 Vdc, 2.6 A
output
max. 12 Vdc 2.5 A / 30 W
working temperature -10 °C ~ +40 °C
working humidity
< 93 % RH
time-delay switch
5s, 30s, 1min, 3min, 5min, 8min.
light control
< 3 lux to 2000 lux
dimensions
visible part
Ø 22 x 10 mm
hidden part (controller) 55 x 25 x 35 mm
weight
± 41 g
Use this device with original accessories only. Velleman nv
cannot be held responsible in the event of damage or injury
resulting from (incorrect) use of this device. For more info
concerning this product and the latest version of this manual,
please visit our website www.velleman.eu. The information in
this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All
worldwide rights reserved.
No part of this manual may be copied,
reproduced, translated or reduced to any electronic medium or
otherwise without the prior written consent of the copyright holder.