background image

 

PIR416 

V. 02 – 03/10/2012 

©Velleman nv 

6.

Connect the wiring 

[1]

 to the terminals according to the diagram 

on page 

2

. Wire colours:  

x  red (+) 

y  black (-) 

z  brown 

Warning:

 do not short-circuit any terminals.  

7.

Connect the power supply. 

8.

To test the PIR sensor, set the light sensitivity to OFF and the 
movement sensitivity and 5” to ON. The load should switch on 
immediately and – when no movement is detected – switch off 
after 5s. 

Note:

 DO NOT change the DIP switch settings when power is 

connected! 

5.

Technical Specification 

detection angle 

100° 

detection range 

8 m (@ 22 °C) 

rated load 

30 W resistive load 

input 

12 Vdc, 2.6 A 

output 

max. 12 Vdc 2.5 A / 30 W 

working temperature  -10 °C ~ +40 °C 
working humidity 

< 93 % RH 

time-delay switch 

5s, 30s, 1min, 3min, 5min, 8min. 

light control 

< 3 lux to 2000 lux 

dimensions 

visible part 

Ø 22 x 10 mm 

hidden part (controller)  55 x 25 x 35 mm 

weight 

± 41 g 

 

Use this device with original accessories only. Velleman nv 
cannot be held responsible in the event of damage or injury 
resulting from (incorrect) use of this device. For more info 
concerning this product and the latest version of this manual, 
please visit our website www.velleman.eu. The information in 
this manual is subject to change without prior notice. 

 

© COPYRIGHT NOTICE 
The copyright to this manual is owned by Velleman nv. All 
worldwide rights reserved. 

No part of this manual may be copied, 

reproduced, translated or reduced to any electronic medium or 
otherwise without the prior written consent of the copyright holder.  

 