PIR415U
V. 06 – 28/04/2015
5
©Velleman Inc.
Warning:
Do not short-circuit any terminals.
8.
Reinstall the fuse of the electric circuit and switch it on.
9.
To test the PIR sensor, set the light sensitivity to OFF and the
movement sensitivity and 5” to ON. The load should switch on
immediately and – when no movement is detected – switch off
after 5 s.
Caution:
DO NOT
change the DIP switch settings when power is
connected.
5.
Technical Specifications
switch type
relay
detection angle
100°
detection range
26 ft.
rated load
load, 150W fluorescent load (120V)
power supply
120 V/50 - 60 Hz
working temperature
14 °F - 104 °F
working humidity
< 93 % RH
time-delay switch
5 s, 30 s, 1 min, 3 min, 5 min, 8 min
light control
< 3 lx to 2000 lx
dimensions
visible part: Ø55/64" x 25/64"
hidden part (controller): 2 11/64" x 1" x
1 3/8"
weight
1.44 oz.
Use this device with original accessories only. Velleman Inc. cannot
be held responsible in the event of damage or injury resulting from
(incorrect) use of this device. For more info concerning this product
and the latest version of this manual, please visit our website
www.velleman.eu. The information in this manual is subject to
change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman Inc. All
worldwide rights reserved.
No part of this manual may be copied,
reproduced, translated or reduced to any electronic medium or
otherwise without the prior written consent of the copyright holder.