background image

PI600M & PI60024 v2                                                                                         GB 

5

 

11. CHASSIS EARTHING 
 
The chassis earthing lug should be connected to an earthing point, which will vary 
depending on where the power inverter is installed. In a vehicle, connect the 
chassis ground lug to the chassis of the vehicle. In a boat, connect to the boat's 
grounding systems. In a fixed location, connect to earth. 
 
 
 
 
 
 
 
 
 
12. CAUTION 
 
In case of trouble with the AC output, e.g. short-circuit, overload, etc… the 
protection circuit will automatically cut off the output. 
In such cases : 

(A)  switch off the power at once 

 

(B)  disconnect all units 

 

(C)  check the connected devices 

 

(D)  use the units again as soon as any problems 

concerning the connected devices have been solved 

 
When in use for a prolonged period of time, the AC output may suddenly be cut 
off although the battery voltage is still very strong. This may be caused by 
excessive temperatures. If this happens, please proceed as follows : 
 

(A)  Switch off the inverter at once 

 

(B)  Disconnect some of the appliances or wait until the inverter cools off 

 

(C)  Switch the inverter back on 

 
Always keep the inverter in an environment which is : 
(A) Well-ventilated 
(B)  Not exposed to direct sunlight or any other heat source 
(C)  Inaccessible to children 
(D)  Safe from water/moisture, oil or grease 
(E)  Safe from any flammable substance 
 
If the inverter is connected in the wrong way, this will void the warranty. 

Summary of Contents for PI600M

Page 1: ... WARRANTY HET TOESTEL ZAL WORDEN BESCHADIGD INDIEN U HET OVERBELAST OF ER EEN INDUCTIEVE BELASTING vb koelkast boormachine ventilator OP AANSLUIT DE GARANTIE VERVALT DAN AUTOMATISCH LA SURCHARGE DE L APPAREIL OU LA CONNEXION D UNE CHARGE INDUCTIVE p ex ventilateur réfrigérateur perceuse ENDOMMAGERONT L APPAREIL ET LA GARANTIE SERA INVALIDEE AUTOMATIQUEMENT DIE GARANTIE ERLISCHT UND DER SPANNUNGSWA...

Page 2: ...nal black terminal of the battery to the binding post black connection of the inverter The length of the cable is 2m Be sure to tighten the screws in order to avoid loose connection 3 OPERATION When connected to an appliance remember to turn on the inverter before turning on the appliance If the buzzer sounds during operation this indicates that the battery voltage is very low and that the inverte...

Page 3: ... being stranded with a dead battery To avoid over discharging the battery you should let your engine run for 10 to 20 minutes after every 2 3 hours of use This allows your vehicle s battery to recharge Please remember to connect the wire to the terminal and the wire to the terminal if you choose to use an adapter in order to establish a direct connection between the AC inverter and the battery ter...

Page 4: ...ether or not you need this terminal Always use heavy duty yellow and green wiring for this connection In a stationary land based installation the earthing terminal should be connected to a metal earthing stake driven into the ground to a minimum depth of 1 2m One of the battery terminals preferably the negative one should also be connected to the earthing stake if the battery system powering the i...

Page 5: ...e the AC output voltage you must use an AUTHENTIC RMS VOLT METER Using any other type of voltage measuring device will result in an AC voltage reading that is up to 20 to 30 volts lower than the rated value The reading will only be accurate when using an authentic RMS voltmeter 10 VENTILATION IMPORTANT During operation make sure the fan keeps revolving Check the inverter for possible malfunctions ...

Page 6: ...ed devices D use the units again as soon as any problems concerning the connected devices have been solved When in use for a prolonged period of time the AC output may suddenly be cut off although the battery voltage is still very strong This may be caused by excessive temperatures If this happens please proceed as follows A Switch off the inverter at once B Disconnect some of the appliances or wa...

Page 7: ...put waveform modified sinewave No load current 1A Battery low alarm shutdown 10 5 0 5VDC for a 12V input 21 1VDC for a 24V input Input current at 100 load 64A for a 12V inverter 32A for a 24V inverter Output current at 100 load 2 6A Overheating protection 55 5 C Dimensions 205 x 73 x 290mm Weight 2 1kg 15 NOTE All specifications are typical at nominal input voltage 50 load and 25 C unless otherwis...

Reviews: