PI600M & PI60024 v2 GB
4
BAD
GOOD
8. FUSE
Please check the fuse if the voltage indicator is not lit during operation. Replace
blown fuses with an identical one.
FUSE : max. 35A for a 12V inverter or 20A for a 24V inverter.
9. MEASURING AC VOLTAGES
The output wave of the AC inverter is a MODIFIED SINEWAVE. If you choose to
measure the AC output voltage, you must use an AUTHENTIC RMS VOLT
METER. Using any other type of voltage measuring device will result in an AC
voltage reading that is up to 20 to 30 volts lower than the rated value. The reading
will only be accurate when using an authentic RMS voltmeter.
10. VENTILATION
IMPORTANT ! During operation, make sure the fan keeps revolving. Check the
inverter for possible malfunctions if the fan does not work when this unit is being
used.
Make sure the fan is not blocked in order to avoid poor ventilation.