5. OUTPUT CAPACITY
The inverter will switch off automatically if the total output capacity of the electrical
appliances exceeds the inverter’s output capacity. This will also happen if the
temperature of the inverter exceeds 55°C due to prolonged use.
6. SPECIAL RECOMMENDATIONS
Unplug the AC inverter when it is not in use or when starting the motor of your
vehicle.
Proceed as follows if the AC inverter makes a beeping sound : switch off your
appliance, unplug the inverter and restart your vehicle's engine. The beeping sound
is simply the battery-low warning, indicating that the voltage of your battery is
getting low. Your inverter will shut down automatically if you continue to use the
inverter without restarting your vehicle's engine. This will leave your vehicle's
battery with ± 10.5VDC, enabling you to restart your engine and resume operation
of the inverter. It also eliminates the possibility of ending up with a dead battery.
Let your engine run for 10 to 20 minutes after every 2-3 hours of using the AC
inverter in order to avoid excessive discharging of the battery. This allows your
vehicle's battery to recharge.
Please remember to disconnect the AC inverter before using the battery charger
to replenish your battery's voltage. Failure to disconnect the inverter prior to
connecting a charger may result in an input spike which will damage the inverter.
CONNECTING THE INVERTER'S INPUT TO A BATTERY CHARGER WILL
VOID THE WARRANTY AND MAY DAMAGE THE INVERTER.
Make sure the battery's voltage never exceeds 15VDC.
CONNECTING THE INVERTER TO A DC POWER SOURCE GREATER THAN
15VDC WILL VOID THE WARRANTY AND MAY DAMAGE THE INVERTER.
WARNING : DO NOT CONNECT ANY INDUCTIVE LOADS WITH THIS DEVICE !