background image

 
 
 
 
 

 
 

 

 

R1 

:  240K   (2 - 4 - 0 - 3 - 1) 

 

R3   :  3K    (3 - 0 - 0 - 1 - 1) 

 

R4   :  4K7    (4 - 7 - 0 - 1 - 1) 

 

R5   :  10K    (1 - 0 - 0 - 2 - 1) 

 

R6 

:  1K8    (1- 8 - 0 - 1 - 1) 

1. Metal film resistors 

R...

Construction 

 

 

 

 

D1  :  1N4007 

 

4. Diode. Watch the polarity ! 

 

 
 
 

 
 

 
 

 

 

 

 

 

 

C1 : 470pF 

 (471) 

 

C2 : 470pF 

 (471) 

2. Capacitors.

 

C...

CATHODE

D...

 

 

 
 
 

 

 
 

 

IC1 : 8p 

 

IC2 : 16p 

3. IC socket. Watch the 
position of the notch!
 

 
 
 
 
 

 

 

R2 

:  18K  (1 - 8 - 0 - 2 - 1) 

 

R7 

:  1K8  (1 - 8 - 0 - 1 - 1) 

 

 

Attention : because one of the 
connections of both R2 and R7 
is a measuring point, it is advis-
able to take care that the body of 
the resistors is on the largest 
circle of the pcb overprint.

 

5. Metal film resistors 

R...

 
 
 
 
 

 

 

 

R8 

:  560  (5 - 6 - 1 - B) 

6. Resistor 

R...

Summary of Contents for K6001

Page 1: ...TEMPERATURE SENSOR K6001 ILLUSTRATED ASSEMBLY MANUAL H6001IP 2 Total solder points 71 Difficulty level beginner 1 2 3 4 5 advanced For use with our K6000 or K6002 kits...

Page 2: ......

Page 3: ...making the distance between the controller and the sensor irrelevant Specifications Temperature range of the transmitter 40 C to 150 C Pulse width modulation 200 s C Generated pulse width at 40 C 2ms...

Page 4: ...he eyes Needle nose pliers for bending leads or to hold components in place Small blade and Phillips screwdrivers A basic range is fine For some projects a basic multi meter is required or might be ha...

Page 5: ...nts are cone shaped and shiny 3 Trim excess leads as close as possible to the solder joint REMOVE THEM FROM THE TAPE ONE AT A TIME AXIAL COMPONENTS ARE TAPED IN THE CORRECT MOUNTING SEQUENCE You will...

Page 6: ...1 C2 470pF 471 2 Capacitors C CATHODE D IC1 8p IC2 16p 3 IC socket Watch the position of the notch R2 18K 1 8 0 2 1 R7 1K8 1 8 0 1 1 Attention because one of the connections of both R2 and R7 is a mea...

Page 7: ...f the sensor Zero Calibration at zero degrees Gain Maximum temperature calibration 7 Multiturn trimmers RV RV C4 10 F C5 10 F C6 10 F C7 220 F 10 Electrolytic Capacitors Watch the polarity C J1 2p 3p...

Page 8: ...1 Using a knife remove the varnish of both pieces of wire over some 3mm from the ends and tin the ends fig 1 1 Cut the connections of the KTY11 KTY81 22 sensor or eq at 3mm fig 1 2 Solder both copper...

Page 9: ...ires and OVER the sensor fig 1 4 Heat the shrinking tube using a hair dryer or better still using a paint stripper Connect the transmitter type KTY11 KTY81 22 or equivalent with the points SENSOR of t...

Page 10: ...circuit with your hands while adjusting it because this could cause noise at its output and consequently a very unstable read out Fill a glass with ice cubes and let them melt a little until you get...

Page 11: ...n against body tempera ture using the GAIN trimming potentiometer It is advisable to verify the temperature at the place of the sensor with a clinical thermometer REMARK If the sensor is intended to b...

Page 12: ...cover plate For making the electrical connections use ordinary wiring or telephone wire of 0 5mm For feeding the sensor use an unstabilised 12VDC power supply which is able to supply at least 20mA yo...

Page 13: ...13 15 PCB layout PCB...

Page 14: ...14 16 Diagram Diagram...

Page 15: ......

Page 16: ...s and typographical errors reserved Velleman Components nv H6001IP 2004 ED2 rev 1 VELLEMAN Components NV Legen Heirweg 33 9890 Gavere Belgium Europe www velleman be www velleman kit com 5 4 1 0 3 2 9...

Reviews: