HAM263D
00 (10/10/2008)
VELLEMAN
16
•
Format:
XXyyyyyy#
XX =
11
USER CODE 1
for arm/disarm control of part. 1
12
USER CODE 2
for arm/disarm control of part. 2
13
USER CODE 3
for arm/disarm control of the
whole system (partition 1 and 2)
yyyyyy =
4 to 6 digits
# =
validation
e.
Memorize frequently bypassed zones (“HOME” mode)
•
HOME mode is only available for use with
USER CODE 3
(whole system). However, partitions
can be bypassed by bypassing the zones within the partition one by one.
•
Zone 8 (24 hour zone) is excluded from use in HOME mode
•
Format:
HOMEyyyyyy#
HOME
Press HOME button on keypad
yyyyyy =
List of zones to be enabled, sequential e.g. 245 to
bypass zones 2, 4 and 5
# =
validation
•
To use the home mode, simply type
USER CODE 3
,
and
; all programmed zones will
automatically be bypassed.
f.
Keypad audible notification set-up
•
Some audible notification can be passed on to the keypad. This is the case for the exit and entry
delay, after an alarm condition and for each key button press.
•
Alarm conditions concerning battery low or AC power failure conditions are always ON.
•
Passing these notifications through to the keypad will not affect the beep settings on the master
control unit.
•
Note that confirmation beeps from the
-button and
-button are always enabled.
14yyyy#
14
master code
yyyy =
4 digits: 0=beep disabled, 1=beep enabled (default)
digit 1 Beep for exit delay
digit 2 Beep for entry delay
digit 3 Beep after alarm condition
digit 4 Beep after each key button press
# =
validation
g.
Alarm detection response time
•
The default zone response time is set to 500ms. This setting can be adjusted independently per
zone, depending on the conditions in that zone.
•
The 8 digit code represents the 8 protection zones. The first digit is zone 1 and the last digit is
zone 8. By putting the timing codes into the specific digit to independently the desired response
time can be set.
15yyyyyyyy#
14
master code
yyyyyyyy =
8 digits, default setting = 3
1 25
ms
2 250
ms
3 500
ms
4 750
ms
# =
validation
h.
Reset system to default
•
To reset the system to its default values, enter code
2100#
.
•
Except for the master code, all other values will be cleared or set to their default.