WIRING

TAMPER

Connect the "TAMPER" terminals
to a normally closed 24-hour
protection area of the control
panel. The tamper contact will
open when the cover is removed.

12V DC

Connect  the  12V  DC  terminals  to  a  power  source  of  8-16VDC,
making sure that they are connected with the correct polarity.

ALARM

Connect the "ALARM" terminals to a normally closed burglar
protection zone of the control panel. The contact will open when an
intruder is detected or during power loss.

TEST POINT (T.P.)

The T.P. is an auxiliary terminal which provides a useful means for
the technician to analyse the detector in the event of an environment
problem or a suspected faulty detector. Connect a DC voltmeter (with
minimum input impedance of 20KOhm/V) with its positive lead to the
T.P. terminal and the negative lead to the (-) 12V DC terminal as
shown in the following diagram.

The meter should read approximately 2.7V DC when no movement is detected. Any
movement into or out of the detection zone will cause the meter to deflect above or below the
2.7 volt level. Any meter variation of +/- 1V will be considered as one pulse which will
trigger an alarm output when the detector is in single-shot operation. If pulse-count operation
is selected, the detector will require a second pulse within 30 seconds after of the end of the
first pulse for the alarm to be triggered.
Using this feature during installation, the alarm contactor can learn of potential false-alarm
problems before permanent fitting of the detector.

Summary of Contents for HAA51

Page 1: ...MODEL HAA51 PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE...

Page 2: ...substantial immunity to false alarms The HAA51 also employs a pulse count triggering circuit which provides further improvement in this respect HAA51 can also be selected for single shot triggering H...

Page 3: ...makes the detector go immediately into the alarm condition whenever an intruder moves in or out of the detection zone The detection circuit requires 1 pulse to activate it It is recommended to use sin...

Page 4: ...ed faulty detector Connect a DC voltmeter with minimum input impedance of 20KOhm V with its positive lead to the T P terminal and the negative lead to the 12V DC terminal as shown in the following dia...

Page 5: ...ot or cold moving air will blow directly onto the unit Avoid aiming the detector at heating or air conditioning vents or ducts exterior metal walls exterior windows or curtains covering windows refrig...

Page 6: ...TEST LED INDICATOR INTO THE INDICATOR HOLE AND KEEP THE HINGED LEVER OF THE TAMPER MICRO SWITCH PRESSED WHEN CLIPPING THE FRONT COVER TESTING a Set the LED selector to ALARM for testing purposes and...

Page 7: ...g levels of infrared energy Clear area of all people and pets If LED remains lit cover detector with heavy paper and wait 1 to 2 minutes If LED extinguishes check each detection zone to locate source...

Page 8: ...installation Mounting location Indoors only flat surface or corner mounting Operating voltage 10 5 16V DC Quiescent current 12mA typical Sensor Dual element pyroelectric sensor with day light filter...

Reviews: