background image

HAA50                                                                                                                                                         VELLEMAN 

2

HAA50 – INFRARED CEILING-MOUNTED PIR DETECTOR 

 
1. Introduction 
 

To all residents of the European Union 
Important environmental information about this product 

This symbol on the device or the package indicates that disposal of the device after its 
lifecycle could harm the environment. Do not dispose of the unit (or batteries) as 
unsorted municipal waste; it should be taken to a specialized company for recycling. 
This device should be returned to your distributor or to a local recycling service. Respect 

the local environmental rules. 

If in doubt, contact your local waste disposal authorities. 

 
The HAA50 is a ceiling-mounted PIR detector, designed for use with residential and commercial 
security applications. It provides a conical detection pattern. This pattern has a Ø of 36ft (11m) 
when the device is mounted on a 12ft- ceiling (3.6m). 
The HAA50 is fitted with pulse-counting PIR detection circuitry and employs a pyroelectric 
sensor equipped with two elements that produce low-level noise only. These two elements also 
provide substantial immunity to false alarm. 
 
2. Detection Pattern 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
3. Mounting Location 
 

  Mount the detector on a stable ceiling at a max. height of 12ft (3.6m). 

  Install the detector in an environment that is shielded from the elements. 

  Select a mounting location that will allow the beams of the detector to pick up the 

movements of possible intruders. 

  Avoid direct exposure to hot or cold air currents. 

  The unit should not be aimed at surfaces that are subject to sudden and violent changes in 

temperature, such as air conditioning vents, exterior metal walls, windows or the curtains in 
front of them, refrigerator or freezer grilles, etc. 

  Do not place large objects in front of the detector, as this will diminish the area covered by 

the detector's beams. 

pulse counter 
selector 

LED 
on/off 

mounting hole 

relay 

wire knockout 

connection 
terminals 

tamper switch 

mounting hole 

PIR sensor 

detection LED 

Summary of Contents for HAA50

Page 1: ...TOR INFRARODE PIR DETECTOR VOOR PLAFONDMONTAGE DETECTEUR PIR POUR MONTAGE AU PLAFOND DETECTOR PIR PARA MONTAJE AL TECHO PIR DETEKTOR F R DECKENMONTAGE USER MANUAL GEBRUIKERSHANDLEIDING NOTICE D EMPLOI...

Page 2: ...fitted with pulse counting PIR detection circuitry and employs a pyroelectric sensor equipped with two elements that produce low level noise only These two elements also provide substantial immunity t...

Page 3: ...back up battery 6 Pulse Counter Selector The user can choose between single pulse or double pulse detection Put the pulse jumper in position 1 for single pulse detection Put the pulse jumper in posit...

Page 4: ...Closed Activation Delay 2 to 3 seconds Alarm Output N C fail safe dry relay contact of 0 5A 24VDC 18 resistor connected in series with the contact Tamper Output N C dry contact Normally Closed of 0 5A...

Page 5: ...lafond van 3 6m hoog De HAA50 maakt gebruik van een PIR detectieschakeling met pulsteller en is uitgerust met een pyro elektrische sensor met twee elementen die weinig ruis produceren Dank zij deze el...

Page 6: ...p batterij te voorzien 6 Jumper voor pulsteller 1 of 2 pulsen U kunt enkelvoudige puls detectie of dubbele puls detectie instellen Plaats de puls jumper op 1 voor enkelvoudige puls detectie Plaats de...

Page 7: ...rm 2 3 seconden Alarmuitgang N C droog relaiscontact bedrijfszeker van 0 5A 24VDC weerstand van 18 in serie geschakeld met het contact Tamperuitgang N C contact Normaal Gesloten van 0 5A 24VDC LED gee...

Page 8: ...HAA50 utilise une zone de d tection conique Cette zone a un de 11m si le d tecteur est attach un plafond d une hauteur de 3 6m Le HAA50 emploie un circuit de d tection PIR avec compteur d impulsions e...

Page 9: ...8 16VCC Respectez la polarit Nous vous conseillons de pr voir une batterie de sauvegarde 6 Compteur d impulsions cavalier Le d tecteur s utilise avec d tection simple ou double impulsion Mettez le cav...

Page 10: ...al 12VCC Sortie relais N F Normalement Ferm Temporisation de d clenchement 2 3 secondes Sortie alarme contact relais sec N F fiable de 0 5A 24VCC r sistance de 18 connect e en s rie avec le contact So...

Page 11: ...i el detector est fijado a un techo con una altura de 3 6m El HAA50 utiliza un circuito de detecci n PIR con contador de pulsos y est equipado con un sensor piroel ctrico con dos elementos que s lo pr...

Page 12: ...a de reserva 6 Puente para el contador de pulsos 1 2 pulsos Es posible seleccionar entre una detecci n de un pulso o una detecci n de dos pulsos Coloque el puente del contador de pulsos en la posici n...

Page 13: ...n de activaci n de 2 a 3 segundos Salida de alarma contacto rel seco N C fiable de 0 5A 24VCC resistencia de 18 conectada en serie al contacto Salida antisabotaje contacto N C Normalmente Cerrado de 0...

Page 14: ...eich mit einem von 11m wenn er an einer Decke von 3 6m befestigt wird Der HAA50 verwendet eine PIR Erfassungschaltung mit Impulsz hler und verf gt ber einen Pyro Elektrischen Sensor mit zwei Elementen...

Page 15: ...er Steuereinheit Ihres Alarms Der Sabotagekontakt ffnet sich wenn das Geh use ge ffnet wird 2 Verbinden Sie die Alarm Anschl sse mit einer normalen geschlossenen N C Anti Einbruch Zone der Steuereinhe...

Page 16: ...fugte den Erfassungsbereich des Ger tes kennenlernen Stellen Sie den LED Jumper auf OFF um die LED auszuschalten 9 Technische Daten Erfassungsbereich kegelf rmiger Erfassungsbereich mit einem Erfassun...

Reviews: