Velleman DVM8928 Manual Download Page 2

DVM8928

 

VELLEMAN 

6. Recording the Maximum and Minimum Measurements 

 
Press 

ON/OFF

 to activate the device. Press the 

RECORD

 button. The message "

REC

" is now displayed in the top 

left-hand corner of the display and the device starts tracking the maximum and minimum sound levels. 
Press 

RECORD

 again. "

MIN

" appears at the top of the screen and the lowest recorded sound level is displayed. No 

new values are displayed digitally at this time, but the bargraph continues to indicate current sound levels. 
 
Press 

RECORD

 again. "

MAX

" appears at the top of the screen and the highest recorded sound level is displayed. No 

new values are displayed digitally at this time, but the bargraph continues to indicate current sound levels. 
 
Press 

RECORD

 again to repeat this process. Hold 

RECORD

 until the "

REC

" symbol is erased from your screen if 

you wish to exit the recording mode. 
 
 

7. Selecting Automatic and Manual Ranging 

 
The meter features 4 measurement ranges in steps of 10dB : 
 

 

40-70dB 

 

60-90dB 

 

80-110dB 

 

100-130dB 

 
The automatic range mode is always installed upon activation of the device : the message "

AUTO

" is displayed in the 

top left-hand corner of the display. In the automatic range mode, the device automatically selects the appropriate 
range. The number in the bottom left-hand corner immediately above the bargraph indicates the lower limit of the 
current range. 
 
The range can also be set manually. This can be very useful if you know the measurement range in advance : the 
meter will be able to execute the readings more quickly, since it does not have to establish the correct range prior to 
performing the actual measurements. 
 
To adjust the range manually : 
 
Hold the 

RANGE

 button for approximately 2 seconds during your measurements : the message "

MANU

" appears on 

the display. Press 

RANGE

 repeatedly until the required range appears on the LCD. Remember that the lower limit of 

the current range is displayed in the bottom left-hand corner of the screen, immediately above the bargraph. 
 
In the manual ranging mode, the message "

LO

" may be displayed. This means that the measured sound levels are 

too low to be registered in the range you have selected. "

HI

" is displayed if the measured sound levels are too high 

for the selected range. Adjust the range in both cases in order to ensure the accuracy of the measurements. 
 
Hold 

RANGE

 for 2 seconds if you wish to return to automatic ranging. 

 

8. Automatic Deactivation 

 
In order to save battery power, the device will be deactivated automatically after an inactivity of 20 minutes. 
 
It is possible, however, to override this feature : 
 
1.  Deactivate the device. 
2.  Press 

ON/OFF

 and 

MAX HOLD

 simultaneously. 

3.  Release 

MAX HOLD

 first when the full display appears : the " " symbol replaces the full display. 

Summary of Contents for DVM8928

Page 1: ...LCD A and dB are displayed on the right hand side of the screen Point the microphone upwards in the direction of the sound source to be measured 3 Selecting the Response Time The user can select eith...

Page 2: ...hand corner immediately above the bargraph indicates the lower limit of the current range The range can also be set manually This can be very useful if you know the measurement range in advance the m...

Page 3: ...k u voor uw aankoop Uw digitale geluidsniveaumeter voert automatische of manuele geluidsniveaumetingen uit in 4 verschillende bereiken van 40 tot 130dB met een resolutie van 0 1dB De gebruiker kan kie...

Page 4: ...toestel in te schakelen Druk de RECORD knop in De boodschap REC opname verschijnt in de linkerbovenhoek van de LCD De meter begint nu de hoogste en laagste waarden te registreren Druk nogmaals op RECO...

Page 5: ...atterij Het BAT symbool verschijnt in de linkerbenedenhoek van de LCD wanneer de batterij moet worden vervangen Schroef het batterijdeksel aan de achterkant van het toestel los met een schroevendraaie...

Page 6: ...ores d intensit et de fr quence variantes La courbe A est utilis e pour des mesures du bruit ambiant dans le design de bureaux le maintien de l ordre publique etc Le calcul selon la courbe C est tr s...

Page 7: ...age correcte Instaurer la plage manuellement Enfoncez RANGE plage pendant 2 secondes pour afficher le message MANU Pressez RANGE plusieurs fois jusqu ce que la plage correcte soit instaur e N oubliez...

Page 8: ...o est tambi n equipado con una funci n max hold un modo de grabaci n para los niveles m x y m n y una salida CA anal gica 2 Medir niveles sonoros El nivel sonoro medido se visualiza digitalmente y por...

Page 9: ...pantalla digital no visualiza ning n valor nuevo aunque la barra gr fica siempre indique los niveles sonoros actuales Vuelva a pulsar RECORD para repetir este procedimiento Pulse RECORD hasta que se...

Page 10: ...ckung zeigt an dass die Entsorgung dieses Produktes nach seinem Lebenszyklus der Umwelt Schaden zuf gen kann Entsorgen Sie die Einheit oder verwendeten Batterien nicht als unsortiertes Hausm ll die Ei...

Page 11: ...ine kleine A oder C rechts im Display zeigt an welcher Modus im Moment eingestellt ist 5 Maximalwert festhalten Max Hold Dr cken Sie die ON OFF Taste um das Ger t einzuschalten Dr cken Sie w hrend die...

Page 12: ...allpegel f r den gew hlten Messbereich zu niedrig sind Die Nachricht HI wird angezeigt wenn die gemessenen Schallpegel f r den gew hlten Messbereich zu hoch sind In beiden F llen m ssen Sie den genaue...

Reviews: