background image

DVM8928

 

VELLEMAN 

DVM8928 -- DIGITAL SOUND LEVEL METER 

 

1. Introduction 

 

To all residents of the European Union 

Important environmental information about this product 

This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm 
the environment. 
Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized 
company for recycling. 

This device should be returned to your distributor or to a local recycling service. 
Respect the local environmental rules. 

If in doubt, contact your local waste disposal authorities. 

 

Thank you for buying the 

DVM8928

! Your digital sound level meter performs automatic or manual sound level 

measurements in 4 different ranges from 40 to 130dB, with a resolution of 0.1dB. 
The user can select fast or slow response times and A- and C-weighting. The device is also equipped with a 
maximum-hold function, a recording mode for max./min. levels and jacks for an analogue AC output. 

 

2. Measuring Sound Levels 

 

The measured sound levels are displayed both digitally and through a bargraph. The digital display is updated every 
160ms, while the bargraph is updated every 40ms. 
Press the 

ON/OFF

 button to activate the device. The DVM8929 will first display a full screen, followed by"

18:8:8

". 

Next, the device will count down from "

99.9

" to "

00.0

". The meter will now start to measure current sound levels and 

the "

SPL

" symbol ("Sound Pressure Level") appears on the left-hand side of the LCD. "

A

" and "

dB

" are displayed on 

the right-hand side of the screen. Point the microphone upwards in the direction of the sound source to be measured. 

 

3. Selecting the Response Time 

 

The user can select either fast or slow response times to suit different applications and meet with certain standards. 

 

The fast response mode is always installed upon activation of the device. Press the 

FAST/SLOW

 button to toggle 

between fast and slow response times. The current response time "(

FAST

" or "

SLOW

") is displayed in the top right-

hand corner of the LCD. 

 

4. Selecting A- or C-Weighting 

 

The A-weighting mode is always installed upon activation of the device. A-weighting enables the meter to respond in 
the same manner as the human ear, which is able to distinguish decreasing and increasing amplitudes at different 
frequencies. Applications for A-weighting include ambient noise measurements, workplace design and law-
enforcement. 

 

C-weighting is suitable for flat response measurements. These are measurements of sources of unchanging intensity 
and frequency. Applications for C-weighting include the sound level analysis of engines and machinery. 

 

Press the 

WEIGHTING A/C

 button to toggle between A- and C-weighting. A small "

A

" or "

C

" on the right-hand side of 

the screen indicates the current mode. 

 

5. Freezing the Maximum Sound Level Reading ("Max. Hold") 

 

Press 

ON/OFF

 to activate the meter. Press the 

MAX HOLD

 button during your measurements in order to freeze the 

maximum reading on the display. This reading will remain on the display until a higher value is measured. Note that 
the bargraph continues to register the current readings : it is not frozen. 
Press 

MAX HOLD

 again to exit the max-hold mode. 

Summary of Contents for DVM8928

Page 1: ...LCD A and dB are displayed on the right hand side of the screen Point the microphone upwards in the direction of the sound source to be measured 3 Selecting the Response Time The user can select eith...

Page 2: ...hand corner immediately above the bargraph indicates the lower limit of the current range The range can also be set manually This can be very useful if you know the measurement range in advance the m...

Page 3: ...k u voor uw aankoop Uw digitale geluidsniveaumeter voert automatische of manuele geluidsniveaumetingen uit in 4 verschillende bereiken van 40 tot 130dB met een resolutie van 0 1dB De gebruiker kan kie...

Page 4: ...toestel in te schakelen Druk de RECORD knop in De boodschap REC opname verschijnt in de linkerbovenhoek van de LCD De meter begint nu de hoogste en laagste waarden te registreren Druk nogmaals op RECO...

Page 5: ...atterij Het BAT symbool verschijnt in de linkerbenedenhoek van de LCD wanneer de batterij moet worden vervangen Schroef het batterijdeksel aan de achterkant van het toestel los met een schroevendraaie...

Page 6: ...ores d intensit et de fr quence variantes La courbe A est utilis e pour des mesures du bruit ambiant dans le design de bureaux le maintien de l ordre publique etc Le calcul selon la courbe C est tr s...

Page 7: ...age correcte Instaurer la plage manuellement Enfoncez RANGE plage pendant 2 secondes pour afficher le message MANU Pressez RANGE plusieurs fois jusqu ce que la plage correcte soit instaur e N oubliez...

Page 8: ...o est tambi n equipado con una funci n max hold un modo de grabaci n para los niveles m x y m n y una salida CA anal gica 2 Medir niveles sonoros El nivel sonoro medido se visualiza digitalmente y por...

Page 9: ...pantalla digital no visualiza ning n valor nuevo aunque la barra gr fica siempre indique los niveles sonoros actuales Vuelva a pulsar RECORD para repetir este procedimiento Pulse RECORD hasta que se...

Page 10: ...ckung zeigt an dass die Entsorgung dieses Produktes nach seinem Lebenszyklus der Umwelt Schaden zuf gen kann Entsorgen Sie die Einheit oder verwendeten Batterien nicht als unsortiertes Hausm ll die Ei...

Page 11: ...ine kleine A oder C rechts im Display zeigt an welcher Modus im Moment eingestellt ist 5 Maximalwert festhalten Max Hold Dr cken Sie die ON OFF Taste um das Ger t einzuschalten Dr cken Sie w hrend die...

Page 12: ...allpegel f r den gew hlten Messbereich zu niedrig sind Die Nachricht HI wird angezeigt wenn die gemessenen Schallpegel f r den gew hlten Messbereich zu hoch sind In beiden F llen m ssen Sie den genaue...

Reviews: