background image

THE LED INDICATORS

MAINS (AMBER)

This is a status indicator. It flashes during standby and other indica�ons in synchroniza�on with 

the pacifier tones. See the chart of LED indica�on signals below for the details.

DOOR (GREEN & RED)

This is a dual LED at the right side of the panel. It lights up in green while output 1 is ac�ve (The 

door is open) and red while Output 1 is Inhibited; including manually inhibited with Super User 

Code or due to False Code Lock-up se�ng in Loca�on 70.

Auxiliary (RED)

It lights up while output 2 is ac�ve.

BACK LIGHTING (BACK-LIT JUMPER SELECTION)

1. FULL BACKLIT

 

---- 

2. AUTO BACKLIT ---- 

3. BACKLIT OFF

 

----- 

THE PACIFIER TONES & THE LED INDICATING SIGNALS

The built-in buzzer and the MAINS LED indicator give the following tones and signals for opera�on 

status:

NOTE:

All Pacifier Tones can be enabled or disabled through programming op�ons at Loca�on 83.

**

 

The Output Ac�va�on Beep can be enabled or disabled through programming op�ons at Loca�on 81.

STATUS

TONES

*

LED SIGNALS

1. In programming mode

---
1 Beep

2 Beeps
5 Beeps

Continuous Beeps
---
1 second Long Beep **

ON
1 Flash

2 Flashes
5 Flashes

Continuous Flashes
1 Flash in 2 seconds interval
---

2. Successful key entry
3. Successful code entry
4. Unsuccessful code entry
5. DAP jumper not replaced
6. In standby mode

7. Output relay activated

 

 

 

The  keypad  gives  dim  backlit  in  standby.  It  turns  to  full  backlit  when  a  key 

bu�on is  pressed,  then  back  to  dim  backlit  10  seconds  a�er  the  last  key  

bu�on  is pressed. 

The  keypad  gives  no  backlit  in  standby.  It  turns  to  full  backlit  automa�cally 

when a key bu�on is pressed, then back to OFF 10 seconds a�er the last key 

bu�on is pressed.

The keypad gives no backlit at all.

7

Summary of Contents for DK-9350

Page 1: ...HAA9350 DUAL OUTPUT FULL FEATURE VANDAL RESISTANT KEYPAD DK 9350 USER MANUAL 2 ...

Page 2: ...ming The Visitor Codes Dele ng User Codes Other Func on Codes Configura on of Output Modes for Outputs 1 2 False A empt System Lock up or Repor ng Door Forced Open Warning Alarm Output Ac va on Announcer User Code Entry Modes Auto or Manual Pacifier Tones ON OFF Main Status LED Flashing ON OFF Egress Delay Warning Delay Time to Start Door Propped Up Warning SET KEYPAD TO SINGLE USER MODE to whom it ...

Page 3: ...a ng op onal electronic door chime The steel box of the DK 9380 is in the size of fi ng the gooseneck pedestal moun ng post It is also suitable for surface mount on wall The flush mount version of the DK 9380 is supplied with a plas c back box that makes it easily moun ng on any brick or wooden wall The DK 9350 is in a smaller size die cas ng moun ng box for surface mount on wall Remark DK 9350 and ...

Page 4: ... while N C contact for Fail safe The output contact is programmable for Start Stop toggle mode or mer mode from 1 to 999 seconds See programming Loca on 40 43 for the details 6 7 8 OUTPUT 2 a Standard Version This is an auxiliary relay output with 1 Amp ra ng Normally Open N 0 and Normally Closed N C dry contacts controlled by the group 2 user codes which is ideal for controlling security systems ...

Page 5: ...lly Closed N C input terminal referring to ground With the help of a normally closed magne c door switch the system monitors the posi on of open or closed of the door and will give the following func ons NOTE Always connect this terminal to ground if not used 1 Door Auto Re lock The system will immediately relock the door a er valid access has been gained before the end of the programmed me for ou...

Page 6: ...ing to ground during the me that the door posi on sensor is open circuit due to door opening Use this output to control the other keypad in an inter lock system to prevent that both doors can be opened at the same me An inter lock system is a two door system that always allows only one door to open during the opera on me While one of the doors in the system is opened the other door keeps close un ...

Page 7: ...tones and signals for opera on status NOTE All Pacifier Tones can be enabled or disabled through programming op ons at Loca on 83 The Output Ac va on Beep can be enabled or disabled through programming op ons at Loca on 81 STATUS TONES LED SIGNALS 1 In programming mode 1 Beep 2 Beeps 5 Beeps Continuous Beeps 1 second Long Beep ON 1 Flash 2 Flashes 5 Flashes Continuous Flashes 1 Flash in 2 seconds i...

Page 8: ... 1 0 to 9 4 to 8 digits 10 User Codes for opera ng Output 2 2 Recording Super User Code User Programming No Default Codes Loca on Entry of Code Confirm Comments 4 to 8 digits Owner s Mul task User Code 3 Recording Duress Codes User Programming No Default Codes Loca on User IDs Entry of Code Confirm Comments 0 to 9 4 to 8 digits 4 Recording the Visitor Codes User Programming No Default Codes Loca on ...

Page 9: ...se code keypad locks during 15 minutes Locking can be released at any me with Super User Code 00 Disappearance of all the above securi es F Door Forced Open Alarm Installer Programming Default Disabled Loca on Func on Codes Confirm Comments Door Forced Open Warning disabled default Door Forced Open Warning enabled ac ve me is 60 seconds G Output Ac va on Door Open Announcer Installer Programming De...

Page 10: ...econds delay with warning 4 Hold contact 10 seconds delay with warning L Delay Time to Start Door Propped up Warning Installer Programming Default OFF Loca on Delay Time Confirm Comments 0 No propped up Warning default 1 to 999 M Exit Programming Mode Confirm Comments It is always necessary to set keypad back to normal opera ons a er programming Manual Entry Mode requires to enter bu on a er the use...

Page 11: ...uld program a new master code to replace the exit factory master code Once a new master code is programmed the old master code is replaced Use DAP jumper to set keypad to programming mode if master code is forgo en See DAP Jumper descrip on for the details The DAP Jumper Direct Access to Programming Mode If Master Code is Forgo en If the master code is forgo en use the DAP jumper located on the ma...

Page 12: ...ase all the current data in memory except the master code and set the keypad back to its default values as like a new unit This may be necessary while the stored data can not be traced or for a new owner who bought a house with a keypad installed The procedures are as follows 1 Set keypad to programming mode with master code and key Taking the previous programmed master code 3 2 8 9 as example her...

Page 13: ...y Chart Sec on C 1 for more informa on See informa on on Loca on 82 concerning digit length in Auto and Manual code entry modes Programming Example 1 Set keypad to programming mode with master code and key Taking the previous programmed master code 3 2 8 9 as example here 2 Program an User Code 8 3 2 1 for output 1 One of the 100 user codes user ID 00 99 taking ID 01 as example 3 Program an User C...

Page 14: ...n C 2 for more informa on See informa on on Loca on 82 concerning digit length in Auto and Manual code entry modes Programming Example 1 Set keypad to programming mode with master code and key Taking the previous programmed master code 3 2 8 9 as example here 2 Program 2 5 8 0 as Super User Code 3 Exit programming mode by pressing the Operation 1 Opera ng Output 1 and 2 Super User Code is just lik...

Page 15: ...put 1 are all temporarily suspended un l SUPER USER CODE is entered again to release the door holding func on The following func ons are Temporary Suspended Door Auto relock Door Forced Open Warning at Loca on 80 Door Propped up Warning at Loca on 9 Dual Keypad Inter lock Opera on All User Codes Including Super User Code for Output 1 Duress Output Actuated by Duress Code for Output 1 3 Inhibi ng T...

Page 16: ...example A Daily User Code is 1 3 5 7 then 3 3 5 7 or 1 3 5 8 may be a good choice for Duress code See Programming Summary Chart Sec on C 3 for more informa on See informa on on Loca on 82 concerning digit length in Auto and Manual code entry modes Programming Example 1 Set keypad to programming mode with master code and key Taking the previous programmed master code 3 2 8 9 as example here 2 Progr...

Page 17: ...hours All Visitor Codes will be deleted a er power lost See Programming Summary Chart Sec on C 4 for more informa on See informa on on Loca on 82 concerning digit length of the code in Auto and Manual code entry modes Programming Example 1 Set keypad to programming mode with master code and key Taking the previous programmed master code 3 2 8 9 as example here 2 Program a Visitor Code 1 3 7 8 at I...

Page 18: ...red Enter Loca on number and User ID if has and the key a Delete a User Code from ID 01 from Output 1 press Loca on 1 User ID 01 and key b Delete a User Code from ID 1 from Output 2 press Loca on 2 User ID 1 and key c Delete the Super User Code press Loca on 45 and key d Delete a Duress Code from ID 2 press Loca on 46 User ID 2 and key e Delete a Visitor Code from ID 3 press Loca on 47 User ID 3 a...

Page 19: ...uired B Loca on 41 or 51 Start Stop Mode toggle The relay outputs can be programmed to trigger ON start and OFF stop with a user code C Loca on 42 or 52 Start Stop Mode toggle with 2 digit Accelerated Code The relay outputs can be programmed to trigger ON with only the first 2 digits of a user code and OFF with a full user code Example a User Code 8 3 2 1 is a full code then the first 2 digit 8 3 is...

Page 20: ... be considered as two user codes with one for star ng and the other for stopping the output Owner can give the accelerated code to the staff to start a system for example an alarm system The staff can only start the system but can not stop it Only the owner can stop the system with the full user code The Super User Code is always valid to Start Stop the relay outputs Super User Code Output 1 Ac vate...

Page 21: ...d to lock 15 minutes a er 5 successive false a empts using incorrect user codes 3 Exit programming mode by pressing the False A empt System Lock up or Repor ng Loca on 70 A er 10 successive false a empts using incorrect user codes the keypad will lock for 30 seconds Default A er 10 successive false a empts using incorrect user codes the Duress Output will ac vate The duress output can be used to t...

Page 22: ...e reset with a user code for output 1 NOTE The door is forced to open without user code or pressing egress bu on Warning ac ve The door is opened with user code or pressing egress bu on No Warning The purpose of output ac va on announcer is to give a sound signal to no fy the visitor outside to open the door when the lock is ac vated It is good for the locking device such as a magne c lock that gi...

Page 23: ... code entry Default User Code Entry Modes Auto or Manual Location 82 Pacifier Tones ON OFF Loca on 83 The status LED typically flashes while the keypad is in standby Some people find it is annoying especially at the night me The LED can be ON or OFF with the se ng here Loca ons Func on Op ons Confirm 0 or 1 Programming Options The status LED flashing is OFF It is good for the people do not like a flashi...

Page 24: ...0 seconds delay and warning beep Press the egress bu on momentary the keypad will beep for 10 seconds before Output 1 ac vates Hold contact for 5 seconds with warning beep Press and hold the egress bu on for 5 seconds and the keypad will beep for those 5 seconds before Output 1 ac vates Hold contact for 10 seconds with warning beep Press and hold the egress bu on for 10 seconds and the keypad will...

Page 25: ... the keypad will generate propped up warning beeps un l the door is re closed This prompts the authorized users to close a door that was not closed properly This func on requires an op onal Normally Closed N C door posi on monitoring switch on the door usually a magne c contact or other door protec on switch with N C contact Loca ons Delay Time Confirm 0 or 1 999 Programming Options Door propped up...

Page 26: ...rs only need one user code for each output and execu ng each of the special func ons Once the keypad is in single user mode there is no User ID required for the codes just simply enter the code to each Loca ons directly Single user mode is prepared for those users who need simple func on and use the default values for their keypad only Please ignore this sec on if it is not suitable for your appli...

Page 27: ...alid within me limit of 1 99 hours Emergency user code for actua ng Output 1 and Duress Output simultaneously to report user under duress Programming Examples for Single User Mode 1 Set keypad to programming mode with the Ex factory Master Code 0 0 0 0 or your Master Code if it was changed 2 Refresh the keypad to Single User Mode with Refreshing code 8 9 0 0 3 Program a new Master Code 3 2 8 9 for...

Page 28: ...VDC Max Ra ng OUTPUT 2 Normally Closed and Normally Open Dry Contacts 1A 24VDC Max Ra ng Tamper Switch Contact Normally Closed Dry Contact 50mA 24VDC Max Duress Inter lock Key Ac ve Output Ra ng NPN Open Collector switches to ground when ac ve 24VDC 100mA Sink Auto Refreshing Time During Code Entry a Eash Digit Maximum Entry Time Limit 10 seconds b Eash Code Maximum Entry Time Limit 30 seconds Wea...

Page 29: ...R LED lights up in Green during the door lock is open Connec on of the door sensing switch is op onal The keypad will provide the following func ons a er it is equipped on door a Door Auto Re lock b Door Forced open Warning c Door Propped up Warning Always connect DOOR SENS terminal to ground if not used APPLICATION EXAMPLES N C DOOR SENS SWITCH OPTIONAL EG IN OUTPUT 1 N C COM N O 12 24V AC DC 1 2...

Page 30: ...N O zone for tamperproof and emergency reporting Connect the common ground to link up the keypad and the alarm control panel to achieve the logical functions is necessary Please also see the NOTE stated in Application Example 1 for the common information EG IN OUTPUT 1 N C COM N O 12 24V AC DC 1 2 3 4 5 6 7 8 9 OUTPUT 2 N C COM N O KEY ACT DU OUT DOOR SENS O P 1 INHIB INT LOCK TAMPER N C GND 10 11...

Page 31: ...ersa Relay output 2 is independent and has nothing concern with the inter lock system It may be used for other applications such as controlling security systems automatic operators etc Please also see the NOTE stated in the Application 1 and 2 for the common information DK 9350 OR DK 9380 DOOR 1 DOOR 2 DK 9350 OR DK 9380 EG IN OUTPUT 1 N C COM N O 12 24V AC DC 1 2 3 4 5 6 7 8 9 OUTPUT 2 N C COM N ...

Page 32: ...as high enough isolation between high voltage and low voltage to prevent damage of the keypad Only one connection option is recommended Make sure the sink current does not exceed the maximum rating of 100mA External power supply and isolation relay are strictly necessary in driving high power device such as lights Door Auto Relock The system will immediately relock the door after a valid access ha...

Page 33: ...Use the Normally Open N O output contact to shunt a Normally Closed N C protection zone of an alarm system Set output contact to Start Stop Mode Programming Option 51 Use the N O or N C output contact to make arm disarm control of an alarm system Consult your alarm control panel manual for the appropriate output contact to be used in arm disarm control Usually set output 2 to Momentary mode Progra...

Page 34: ...ng of 30VDC 1A It is prepared for triggering of a door chime G DOOR BELL DOOR BELL N O ELECTRONIC DOOR CHIME DOOR BELL BUTTON F DOOR BELL The Door Bell terminal is a Normally Open relay contact with the power rating of 30VDC 1A It is prepared for triggering of a door chime 34 ...

Page 35: ...TPUT An open collector output is equivalent to a Normally Open N O contact referring to ground similar to a relay contact referring to ground The transistor is normally OFF and its output switches to ground when ac ve The open collector can only provide switching func on for small power but it is usually good enough for controlling of an alarm system The Duress Inter lock and Key Ac ve Alarm Outpu...

Page 36: ...alls dust dirt humidity and by the article as well as its contents e g data loss compensation for loss of profits consumable goods parts or accessories that are subject to an aging process during normal use such as batteries rechargeable non rechargeable built in or replaceable lamps rubber parts drive belts unlimited list flaws resulting from fire water damage lightning accident natural disaster ...

Reviews: