background image

LCD and 16-Zone LED Keypads

1689

1641

16-Zone LED Keypad

LCD Keypad

User’s Manual

http://www.ealarm.com.my

Summary of Contents for Spectra 1689

Page 1: ...LCD and 16 Zone LED Keypads 1689 1641 16 Zone LED Keypad LCD Keypad User s Manual h t t p w w w e a l a r m c o m m y...

Page 2: ...ay 9 2 7 Partitioning 13 3 0 PROGRAMMING ACCESS CODES 14 3 1 System Master Code Default 123456 14 3 2 Master Codes 14 3 3 Duress Code 15 3 4 Programming Access Codes 15 4 0 ARMING DISARMING 17 4 1 Exi...

Page 3: ...ting 29 5 3 Panic Alarms 30 5 4 Program Time clock 30 5 5 PGM Button Programmable Outputs 31 5 6 Quick Function Keys 31 5 7 Keypad Settings For LCD Keypads only 32 6 0 FIRE ALARMS 33 7 0 TESTING MAINT...

Page 4: ...anyone can use without memorizing complex and confusing codes The system consists of the Spectra Control Panel one or more Spectra Keypads various input devices i e motion detectors door contacts etc...

Page 5: ...ion beep and the action will be cancelled Refer to System Checklist in section 8 0 for details 2 1 KEYPAD INDICATOR LIGHTS The state of each light on the Spectra Keypads represents a specific conditio...

Page 6: ...FEEDBACK 2 2 1 For the Spectra 1689 LED Keypad The numbers and symbols on the keypad s screen communicate your system s status as shown in Figure 2 2 Figure 2 2 Overview of the 1689 LED Keypad h t t p...

Page 7: ...it will guide you with beep tones You should be familiar with these Confirmation Beep When an operation i e arming disarming is successfully entered on the keypad or when the system switches to a new...

Page 8: ...rming the system press the MEM button to illuminate the number symbols corresponding to the zones that were in alarm To exit the Alarm Memory Display press the CLEAR button For Spectra 1641 LCD Keypad...

Page 9: ...e 2 4 Once you enter the Event List the time the event occurred and what event occurred will scroll on the screen As you press the V button the next pair will scroll Figure 2 4 Example of Event Screen...

Page 10: ...5 seconds whenever a new trouble condition has occurred Press the TRBL button to stop the Trouble Beep For Spectra 1689 LED Keypad When a trouble condition occurs the TRBL symbol will illuminate How D...

Page 11: ...ackup battery is disconnected or the battery voltage is getting low 2 Wireless Transmitter Battery Low The battery voltage in one or more Wireless Transmitters is getting low Also the device s yellow...

Page 12: ...t will automatically shut down if the current exceeds a predetermined value When the system is disarmed the current is cut from the bell output and the Trouble warning may extinguish but the Trouble m...

Page 13: ...wiring problem on the fire zone is occurring 12 Module Loss A module is no longer communicating with your system To re program the clock press the 8 button after Step 2 from the Trouble Display see Ho...

Page 14: ...hat can divide your alarm system into two distinct areas identified as Partition 1 and Partition 2 Partitioning can be used in installations where shared security systems are more practical such as a...

Page 15: ...hecklist in section 8 0 3 1 SYSTEM MASTER CODE Default 123456 The System Master Code can arm or disarm any partition using any of the methods described in this section and can create modify or delete...

Page 16: ...the Access Code assigned to User 048 will arm or disarm the system and immediately transmit a silent alert Duress Code to the Security Company Must be enabled by your installer 3 4 PROGRAMMING ACCESS...

Page 17: ...to exit How Do I Delete Access Codes 1 Repeat steps 1 to 3 see above 2 Press the FORCE button once for each digit in the Access Code 4 or 6 times until the keypad emits a CONFIRMATION BEEP then press...

Page 18: ...the Exit Delay 4 2 DISARMING DEACTIVATING AN ALARM To disarm an armed system or an alarm enter your access code An entry point like the front door will be programmed with one of two Entry Delay Timers...

Page 19: ...try point i e front door 2 Enter your ACCESS CODE IF YOU HAVE ACCESS TO BOTH PARTITIONS see section 2 7 3 Press the button corresponding to the desired partition 1 or 2 For both partitions press the o...

Page 20: ...tectors Stay Arming can also be activated using Auto Arming see section 4 9 a Keyswitch see section 4 8 or One Touch Arming see section 4 7 How Do I Stay Arm 1 Close all zones in the desired partition...

Page 21: ...d zone that is breached will immediately generate an alarm If you have access to both partitions To Instant Arm one partition 1 Press the STAY button 2 Enter your ACCESS CODE 3 Choose a partition 4 Pr...

Page 22: ...mple when arming and the motion detector is a Force Zone the system will allow you to arm even if the zone is open Force Arming can also be activated by using One Touch Force Arming see section 4 7 6...

Page 23: ...When zones are bypassed the BYP symbol will illuminate Manual Bypass Programming can also be activated by using One Touch Bypass Programming see section 4 7 7 To remove the Bypass feature from a zone...

Page 24: ...1 or 2 4 6 2 Bypass Recall Feature After disarming the system the bypass entries are erased The Bypass Recall Feature reinstates the previous bypass entries saved in memory This eliminates the need to...

Page 25: ...er alarm system operations For details on Regular Arming refer to section 4 3 4 7 4 One Touch Stay Arming Press and hold the STAY button for 3 seconds see Note1 p 23 to arm all zones not defined as St...

Page 26: ...gular Arming see section 4 3 Exit and Force Arm Press and hold the FORCE button for 3 seconds see Note1 p 23 to start the Exit Delay see section 4 1 When the Exit Delay elapses the system will switch...

Page 27: ...tch set the keyswitch to the on position To disarm the system set the keyswitch to the off position To arm the system using a Momentary Keyswitch set the keyswitch to the on position then turn it back...

Page 28: ...can be programmed to arm the system and or send a report if no zone activity occurs for a pre programmed amount of time This is a particularly useful feature when supervising an individual with chron...

Page 29: ...he number extinguishes or press FORCE to remove Chiming from all zones programmed to Chime When you program Chime Zones once you press and hold the 9 button the ARM1 STAY1 ARM2 STAY2 BYP MEM and TRBL...

Page 30: ...sed Therefore when muted the keypad will not beep during an alarm Press and hold the CLEAR button for 3 seconds to enable or disable Keypad Muting If the keypad emits a confirmation beep Keypad Muting...

Page 31: ...an communicate specific messages to your monitoring station For instance pressing 1 3 can mean call the police or anything you require Press hold buttons 1 and 3 for the police Press hold buttons 4 an...

Page 32: ...3 seconds 5 6 QUICK FUNCTION KEYS Upon request of your installer or Security Company you may have to perform one of the following Press 5 6 1 Test Report ENTER MASTER CODE MEM If your system is monito...

Page 33: ...pads only You can modify the keypad s setting to suit your needs 1 Press hold 6 for 3 seconds 2 Choose one Press 1 Backlight the keypad s light 7 is the brightest 2 Contrast character intensity 7 is t...

Page 34: ...porting of false alarms If there is no fire condition contact your Security Company immediately to avoid an unnecessary response What do I do if a Delayed Fire Zone was set off accidentally 1 Press th...

Page 35: ...of the report delayed for 30 seconds Has CLEAR been pressed within 30 seconds Bell siren silenced Report transmission delayed an additional 90 seconds Problem corrected Generate alarm and alert Securi...

Page 36: ...since the heating systems in single family homes are often not professionally maintained Fire Safety Tips In the event of a fire remember time is the biggest enemy and every second counts Escape first...

Page 37: ...smoke and deadly gases that can overcome occupants while they sleep To warn against fire smoke detectors should be installed outside each separate sleeping area in the immediate vicinity of the bedroo...

Page 38: ...t way to test your particular system Do not use open flame or burning materials to test your fire detection devices Contact your installer for safe methods of testing your system Under normal use your...

Page 39: ...Stay Force 24Hr Entry Delay 01 _______________ ____ N N N N N 02 _____________ Keyswitch Y N N N Type ____________ ____ N N N N N 03 ______________ Fire Zone Y N N N Delayed Y N N N ____ N N N N N 04...

Page 40: ..._____________ ____ N N N N N 15 _______________ ____ N N N N N 16 _______________ ____ N N N N N User and Name Partition 1 or 2 Byp Stay Force Arm Only PGM Only 001 ____________ System Master Code Def...

Page 41: ...__________ ____ N N N N N 015 _____________ ____ N N N N N 016 _____________ ____ N N N N N 017 _____________ ____ N N N N N 018 _____________ ____ N N N N N 019 _____________ ____ N N N N N 020 _____...

Page 42: ...___________ ____ N N N N N 035 _____________ ____ N N N N N 036 _____________ ____ N N N N N 037 _____________ ____ N N N N N 038 _____________ ____ N N N N N 039 _____________ ____ N N N N N 040 ____...

Page 43: ...N Audible N Off 4 6 Aux or ___________ N Silent N Audible N Off 7 9 Fire or ___________ N Silent N Audible N Off PGMs PGM 1 ___________________________________________ PGM 2 __________________________...

Page 44: ...isarm before alarm enter through zone ___________ Alarm will activate siren or bell for ______ min Other Information Installed by __________________ Date ______________ Serviced by __________________...

Page 45: ...mmed digit will illuminate and so forth For example if you wish to change User Code 004 from 123456 to 454545 after entering section 004 number 1 will turn on Press the 4 button and number 2 will turn...

Page 46: ...oducts not manufactured by Seller Seller cannot guarantee the performance of the security system Seller obligation and liability under this warranty is expressly limited to repairing or replacing at S...

Page 47: ...h t t p w w w e a l a r m c o m m y...