Velleman DCM267 User Manual Download Page 7

DCM267                                                                                                                                                                    GB 

Power Supply 

9V-battery (NEDA1604 or IEC6F22) 

Battery-Low Indication 

The 

-symbol is displayed 

Operating Temperature 

0 to +40°C 

Storage Temperature 

-10 to +50°C 

Temperature Coefficient 

0.1 x specified accuracy / °C (<18°C or > 28°C) 

Max. Altitude 

2000m above sea level 

Dimensions 

282mm (L) x 104mm (W) x 47mm (H) 

Weight 

±

 500g 

 
 
7.1. DC  Voltage 
 

Range Resolution 

Accuracy 

2V 1mV 

20V 10mV 

200V 0.1V 

 

±0.5% of rdg ± 1 digit 

1000V 

1V 

±1.0% of rdg ± 2 digits 

Input impedance : 10M

 
7.2. AC  Voltage 
 

Range Resolution 

Accuracy 

200V 0.1V 
750V 1V 

±1.0% of rdg ± 3 digits 

Input impedance : 10M

 

Response 

: average response, calibration in rms of a sine wave. 

Frequency range : 40Hz – 400Hz 
 
7.3. AC  Current 
 

Range Resolution 

Accuracy 

200A 0.1A 

1000A 1A 

< 600A : ± 2.0% of rdg ± 5 digits 
> 600A : ± 3.0% of rdg ± 5 digits 

Overload protection : 1200A for 60 max. seconds. 
Frequency range 

: 50Hz to 60Hz 

 
7.4. Resistance 
 

Range Resolution 

Accuracy 

200

Ÿ

 0.1

Ÿ

 

±1.0% of rdg ± 3 digits 

20k

Ÿ

 10

Ÿ

 

±1.5% of rdg ± 5 digits 

2M

Ÿ

 1k

Ÿ

 

±1.5% of rdg ± 5 digits 

 
7.5. Temperature in C° 
 

Range 

Resolution 

Testing Range 

Accuracy 

0°C to 400°C 

±1.0% of rdg ± 3 digits 

 

0°C to 750°C 

 

1°C 

400°C to 750°C 

±2.0% of rdg ± 1 digit 

 

Summary of Contents for DCM267

Page 1: ...DCM267 DIGITAL CLAMP METER DIGITALE STROOMTANG PINCE AMPEREMETRIQUE DIGITALE STROMZANGE User Manual Gebruikershandleiding Manuel d utilisation Gebrauchsanleitung...

Page 2: ...ments Just like all other electrical measuring instruments the DCM267 will respond to unwanted signals e g transients that may occur in the circuit being tested Exercise extreme caution when using thi...

Page 3: ...current resistance frequency temperature C F diodes and continuity 5 Description of the Front Panel Jaws They pick up the AC current flowing through the conductor Hold button Press this button to free...

Page 4: ...DCM267 GB 3...

Page 5: ...jack and the black test lead to the COM jack The polarity of the red test lead is positive 2 Use the rotary switch to select the desired range 3 Connect the test leads to the resistor to be measured a...

Page 6: ...h in the position 3 Connect the red test lead to the anode and connect the black test lead to the cathode of the diode to be tested 4 The approximate forward voltage drop of the diode will be displaye...

Page 7: ...ce 10M 7 2 AC Voltage Range Resolution Accuracy 200V 0 1V 750V 1V 1 0 of rdg 3 digits Input impedance 10M Response average response calibration in rms of a sine wave Frequency range 40Hz 400Hz 7 3 AC...

Page 8: ...e battery compartment Only use the device if the cover is in place and the screws are tightened in order to avoid electroshocks The symbol is displayed if the battery needs to be replaced Use the foll...

Reviews: