Specifications
Maximum sample rate
2x 240MS/s for repetitive signals ( 2x 60MS/s for single shot events)
Maximum input amplifier bandwidth
30MHz ( -3dB ) per channel
Input impedance
1Mohm // 20pF (standard oscilloscope probe)
Maximum input voltage
100Vpeak (AC + DC), 200Vpeak-peak (AC only)
Input coupling
DC, AC and GND (GND for auto zero reference)
Vertical resolution
8 bit ± 1bit linearity
Trigger modes
Run, Normal, Once, Roll mode for 10s/div and slower timebase
Trigger level
Adjustable with positive or negative slope selection
LCD Graphics
128 x 192 pixels with LED backlight
Signal storage
256 samples per channel, 2048 in roll mode
dBm measurement (0dBm= 0.775V)
From –80dB tot +38dB (up to 58dB with X10 probe) ±0.5dB accuracy
dBV measurements (0dBV= 1V)
From -78dB tot +40dB (up to 60dB with X10 probe) ±0.5dB accuracy
True-rms measurement
From 0.03mV to 80V (up to 400Vrms with X10 probe) 2.5% accuracy
Timebase range in 35 steps
25ns to 1hour/division
Input sensitivity range in 14 steps
1mV to 20V/division at X1 - 10mV to 200V/div at X10 prope
Probe calibration output
1,2KHz / 3Vpp
Supply voltage
9VDC/ min 500mA regulated adapter
Batteries
6V / 1800mA battery pack NiMH rechargeable
Charge current for rechargeable batteries
400mA fast charge (50mA trickle charge)
Current consumption current (average)
On: 350mA, with backlight: 400mA, standby current: < 100µA
Operating temperature
0 to 50°C (32 to 122°F)
Fysical characteristics
Dim: 230x150x50mm (9x5.9x1.97”) Weight: 870g incl. Batteries
Interface to PC
Internal optical isolated RS232, 115200Baudrate for screen and data load/set
Firmware
Upgradable through internet
Protection
IEC1010, 600V CATII, pollution degree 1 (IP40)