MINI PC SCOPE PCSU01 
 
User manual

 

F e a t u r e s  

 

test leads 

 

software download 

 

USB cable 

 

design enclosure 

S p e c i f i c a t i o n s

 

 

oscilloscope: 

o

 

bandwidth: DC to 200 kHz ± 3 dB 

o

 

input impedance: 100 kO / 20 pF 

o

 

maximum input voltage: 30 V (AC + DC) 

o

 

time base: 10 µs to 500 ms per division 

o

 

input range: 100 mV to 5 V/division 

o

 

input sensitivity: 3 mV display resolution 

o

 

readouts: true RMS, dBV, dBm, p to p, Duty cycle, Frequency… 

o

 

record length: 1k samples 

o

 

sampling frequency: 62.5 Hz to 1.5 MHz 

o

 

sample history function 

o

 

auto set-up function 

o

 

pre-trigger function: on 0.1 ms/div .. 500 ms/div ranges 

o

 

persistence options: colour graded, Variable and Infinite 

 

spectrum analyser: 

o

 

frequency range: 0 .. 150 Hz to 75 kHz 

o

 

operating principle: FFT (Fast Fourier Transform) 

o

 

FFT resolution: 512 lines 

 

transient recorder: 

o

 

timescale: 20 ms/div to 2000 s/div 

o

 

max. recording time: 9.4 h/screen 

o

 

automatic storage of data 

o

 

record and display of screens 

o

 

max. number of samples: 100/s 

o

 

min. number of samples: 1 sample/20 s 

 

general information: 

o

 

markers for: amplitude/voltage and frequency/time 

o

 

input coupling: DC and AC 

o

 

8 bit resolution 

o

 

storage of display and data 

o

 

dimensions: 85 x 40 x 14 mm 

 

minimum system requirements: 

o

 

Windows® XP, Vista, 7, 8, 10 

o

 

mouse (or mouse pad) 

o

 

free USB port 1.1 or 2.0 

Software installation

 

 
Download the latest software version from 

www.velleman.eu.

 

Type PCSU01 in the search box and check the download section. 
• Download the PCSU01_setup.zip file 
• Unzip the files in a folder on your drive 
• Double click the “setup.exe” file 
An install wizard will guide you through the complete installation 

Summary of Contents for 5410329646165

Page 1: ... o operating principle FFT Fast Fourier Transform o FFT resolution 512 lines transient recorder o timescale 20 ms div to 2000 s div o max recording time 9 4 h screen o automatic storage of data o record and display of screens o max number of samples 100 s o min number of samples 1 sample 20 s general information o markers for amplitude voltage and frequency time o input coupling DC and AC o 8 bit ...

Page 2: ...ower mains If necessary use a safety isolation transformer Warranty This product is guaranteed against defects in components and construction from the moment it is purchased and for a period of ONE YEAR starting from the date of sale This guarantee is only valid if the unit is submitted together with the original purchase invoice VELLEMAN Ltd limits its responsibility to the reparation of defects ...

Page 3: ...t observe the max input rating of the scope Start measuring with trigger off 5 Press RUN 6 Choose the desired volts div setting or press Auto set 2 Choose the appropriate time div setting 7 To enable triggering Select trigger edge 4 Set trigger to ON 5 Set trigger level by sliding 3 The trigger mark is displayed on the left hand side of the signal display 1 1 2 3 4 7 5 6 ...

Page 4: ... the circuit under test observe the max input rating of the scope First observe the signal on the scope screen see previous page Check that the signal is not over the maximum of the screen Start the spectrum analyzer Press RUN 1 Select the appropriate frequency range Make sure your setting will capture any signal change of interest 3 If wanted set the appropriate volts div setting 2 2 3 1 ...

Page 5: ...he circuit under test Select the appropriate volts div setting 1 Select the appropriate time division setting 3 Press RUN 2 to start recording Press RUN again to stop the measurement or use the Single button to make a single screen measurement For continuous recording with auto save to your HD select AutoSave Data from the File menu Notes During recording the screen can differ from the actual meas...

Page 6: ...evel Selects the signal level at which the sweep is triggered Triggering reference mark is displayed with the horizontal line on the left side of the screen TRIGGER Edge Selects the triggering slope Up Trigger occurs when triggering signal crosses trigger level in a positive going direction Dn Trigger occurs when triggering signal crosses trigger level in a negative going direction TRIGGER Find Re...

Page 7: ... the history menu The history menu options are Clear History Save History Open History Hide History Bar Show Hint Spectrum analyzer mode FREQ RANGE Sets the frequency range of the display Menu options File menu Note Default folder Documents My PCSU01 for image and data files is created when the program is run for the first time Open Image Opens an image file and displays it on the screen Open DSO ...

Page 8: ... is displayed in Run mode RMS Average Use this averaging mode to reduce signal fluctuations Vector Average Use this averaging mode to reduce random or uncorrelated noise in the synchronous signal you want to display Hardware setup Select the hardware Colors Select the display colors Skins Give the software a new look by applying a different skin Persistence Options Select the persistence settings ...

Page 9: ...arameters Software automatically calculates various voltage and time parameters of a signal such as DC mean amplitude rise time etc These parameters are displayed in a separate window Use the check boxes in the window to select the parameters you which to be displayed Markers Displays Markers on the screen Bright Grid Brightens the signal grid on the screen Dot Join On The dots of the acquired wav...

Page 10: ...d the text edit window is cleared and the selected waveform parameters data replaces the text Tip You can use Ctrl A Ctrl C and Ctrl V shortcuts in the text edit window To make the text transparent with the background check Transparent text The text will have the same color as the vertical time frequency markers Troubleshooting No signal on the oscilloscope display No communication with the comput...

Reviews: