If you have any smoke or gas detectors, connect them across pin 1
and pin 4.
If you have any PIR, door switch or broken glass detectors, connect
them across pin 2 and pin 4.
If you have any panic/emergency button, connect them across pin 3
and pin 4.
Pin 4 and pin 5 provide 12V DC output for the detector. Pin 4 is 12V
DC "-" (negative) polarity. Pin 5 is 12VDC "+" (positive) polarity.
2) The detector used should be a "normally closed" (N.C.) device. Any
of the 3 pins (pin 1, 2, 3) and pin 4 of the terminal form a closed loop
with the detector. If the circuit between any of the 3 pins and pin 4 is
opened, the alarm will be activated.
3) When the detector connector to the Voice Dialler is activated, the
Voice Dialler will directly dial and play the message recorded.
However, the Main Unit will not be activated.
7. Important notes
1) When only one number is stored and the number is engaged, the
Voice Dialler will automatically redial that number up to maximum
of 5 times with an interval of 62 seconds.
2) When more than one telephone numbers are stored, the Voice Dialler
will dial in accordance to the priority number. If the number being
dialled is engaged, it will try the next number and so on.
Each number will be tried a maximum of 5 times and the redial
interval between each number is 35 seconds.
3) When the Voice Dialler has reached 2 successful phone calls, it will
stop dialling.
4) When the recipient has answered the call, the Voice Dialler will start
to play the message after 2 to 5 seconds thereafter. It will repeat the
message for 3 times.