21 |
Page
6.2 Unit not cooling
Turn on the unit and use a pressure gauge to measure the pressure at the low-pressure
port. Use this chart to find the nominal pressure value based on the ambient temperature.
If the pressure is lower than the nominal value, use a R134a recharge kit (can be purchased
from Auto part stores and Home Depot) to charge the unit to the desired pressure.
If there is oil or other signs of a refrigerant leakage, reach out to a mechanic or RV
technician to identify and fix the leak. Vacuum the system and charge with 400g of R134a.
Ambient (Outside)
Temperature
℉
Standard Low Side
Pressure Range
PSI
65
25-35
70
35-40
75
35-45
80
40-50
85
45-55
90
45-55
95
50-55