![Veit 8905 Original Instruction Manual Download Page 42](http://html2.mh-extra.com/html/veit/8905/8905_original-instruction-manual_4559694042.webp)
Kragen- und Manschettenpresse 8905
8905 Collar and Cuff Press
23.05.2017
42
No.
Description
Reason
Trouble Shooting
1
No function at all
Main switch switched off
Switch on main switch
No supply voltage
Reconnect power supply and check
No compressed air
Reconnect compressed-air supply
Switch at safety frame S1, S1.1, S1.2,
S1.3 defective
Check and replace if necessary
Safety relay K1 defective
Check and replace if necessary
Reset button S2 defective
Check and replace if necessary
Power pack T1 defective
Check and replace if necessary
Fuse F3 has triggered
Search and clearing faults,
fuse switch on
Main switch Q0 defective
Check and replace if necessary
2
Head buck does not open /close
5/2 directional control valve Y3
defective
Check and replace if necessary
Pedal „Start“ S11 defective
Check and replace if necessary
Process control CD12 defective
Check and replace if necessary
3
Head buck does not open /close
properly
Insufficient compressed-air supply
Check compressed-air supply
provided by customer
End-of-travel damping set incorrectly
Readjust end positions at cylinder Z1
or replace sealing
One-way restrictor V2, V3 set
incorrectly
Check and reset or replace if
necessary
Cylinder Z1 leak
Check tightness and
replace if necessary
4
No function at heating
Process control SD12 defective
Check and replace if necessary
Temperature sensor R9 defective
Check and replace if necessary
Resistor R8 defective
Check and replace if necessary
4.1
Head buck-Cuff heating plate does not
heat
Fuse F3 has triggered
Search and clearing faults,
fuse switch on
Contactor K3 defective
Check and replace if necessary
Hot element R4, R6 defective
Check and replace if necessary
Thermostat B1, B2 defective
Check and replace if necessary
Head buck-Collar heating plate does
not heat
Fuse F2 has triggered
Search and clearing faults,
fuse switch on
Contactor K3 defective
Check and replace if necessary
Hot element R5 defective
Check and replace if necessary
4.2
Lower buck-Cuff heating plate does
not heat
Fuse F1, F4 has triggered
Search and clearing faults,
fuse switch on
Hot element R1, R3 defective
Check and replace if necessary
Lower buck-Collar heating plate does
not heat
Fuse F2, F5 has triggered
Search and clearing faults,
fuse switch on
Hot element R2 defective
Check and replace if necessary
Summary of Contents for 8905
Page 45: ...Kragen und Manschettenpresse 8905 8905 Collar and Cuff Press 23 05 2017 45 102 404 405 201 406...
Page 46: ...Kragen und Manschettenpresse 8905 8905 Collar and Cuff Press 23 05 2017 46 103 202 203 204 205...
Page 47: ...Kragen und Manschettenpresse 8905 8905 Collar and Cuff Press 23 05 2017 47 104 206 104 105...
Page 49: ...Kragen und Manschettenpresse 8905 8905 Collar and Cuff Press 23 05 2017 49 218 219 407 408 409...
Page 55: ...Kragen und Manschettenpresse 8905 8905 Collar and Cuff Press 23 05 2017 55...
Page 57: ...Kragen und Manschettenpresse 8905 8905 Collar and Cuff Press 23 05 2017 57...
Page 58: ...Kragen und Manschettenpresse 8905 8905 Collar and Cuff Press 23 05 2017 58...
Page 59: ...Kragen und Manschettenpresse 8905 8905 Collar and Cuff Press 23 05 2017 59...
Page 60: ...Kragen und Manschettenpresse 8905 8905 Collar and Cuff Press 23 05 2017 60...
Page 61: ...Kragen und Manschettenpresse 8905 8905 Collar and Cuff Press 23 05 2017 61...
Page 62: ...Kragen und Manschettenpresse 8905 8905 Collar and Cuff Press 23 05 2017 62...
Page 63: ...Kragen und Manschettenpresse 8905 8905 Collar and Cuff Press 23 05 2017 63...
Page 64: ...Kragen und Manschettenpresse 8905 8905 Collar and Cuff Press 23 05 2017 64...